Fluke Networks DSX2-5000QI
Catalog #: 4955021
1 GHz DSX Cable Analyzer with Quad OLTS, Inspection Camera and Wi-Fi
- Overview
- Specifications
- Summary
- Reflectometers
- Adapters
- Reference Modules
Product Highlights
- Versiv modular design supports copper certification, fiber optic loss, OTDR testing and fiber end-face inspection
- Unmatched speed for Cat 6A, 8, Class FA, I/II and all current standards
- ProjX system manages job requirements and progress from set-up to systems acceptance, making sure all tests are completed correctly
- Taptive user interface simplifies set-up, and eliminates errors
- Analyze test results and create professional test reports using LinkWare management software
- Graphically displays the source of failures including crosstalk, return loss and shield faults for faster troubleshooting
- Intertek Verified to TIA Level 2G the most stringent accuracy requirement
- Endorsed by cabling vendors worldwide
- Built in Alien Crosstalk testing capability
- Compatible with Linkware Live. Linkware Live enables to easily track job progress, get real-time access to test results to quickly fix problems in the field, and easily transfer and consolidate test results from the tester to LinkWare PC Cable Test Management Software.
Each Unit Includes
- 1 Versiv Mainframe & Remote
- (2) DSX-5000 CableAnalyzer Modules
- (2) CertiFiber Quad OLTS Modules
- Set of Cat 6A/Class EA Permanent Link Adapters
- Set of Cat 6A/Class EA Channel Adapters
- (2) Headsets
- (2) Hand straps
- (2) Shoulder Straps
- Carry Case
- USB Interface Cable
- Versiv Open Source Software CD
- (2) AC Chargers
- (2) Universal Couplers
- USB Video Inspection Probe w/ 4 Tips
- (2) Quick Clean Cleaners (1.25/2.50 mm)
- (2) LC/LC Simplex Adapters
- SC/LC EF-Compliant MM TRC Kit 50 µm
- SC/LC SM TRC Kit
- TRC Carry Case
- Statement of Calibration
- Getting Started Guides
DSX CableAnalyzer Series Specifications |
Cable Types |
Shielded and unshielded pair LAN cabling |
TIA Cat 3, 4, 5, 5e, 6, 6A, 100 Ω ISO/IEC Class C, D, E, EA, F, FA and I/II: 100 Ω and 120 Ω |
Standard Link Interface Adapters |
Permanent link adapters |
Plug type: shielded RJ45
Optional Plug type: Tera |
Channel Adapters |
Jack type: shielded RJ45
Optional Jack type: Tera, GG45 |
Test Standards |
TIA |
Cat 3, 4, 5, 5e, 6, 6A, 8 per TIA 568 Series |
ISO/IEC |
Class C, D, E, EA, F, FA, I/II certification per ISO/IEC 11801 Series |
Maximum frequency |
DSX-5000 1000 MHz |
General Specifications |
Autotest Time |
DSX-5000: Full 2-way Autotest of Cat 5e or 6/Class D or E: 9 seconds Full 2-way Autotest of Cat 6A/Class EA: 10 seconds |
Support test parameters (The selected test standard determines the test parameters and the frequency range of the tests) |
Wire Map, Length, Propagation Delay, Delay Skew, DC Loop Resistance, Insertion Loss (Attenuation), Return Loss (RL), NEXT, Attenuation-tocrosstalk Ratio (ACR-N), ACR-F (ELFEXT), Power Sum ACR-F (ELFEXT), Power Sum NEXT, Power Sum ACR-N, Power Sum Alien Near End Xtalk (PS ANEXT), Power Sum Alien Attenuation Xtalk Ratio Far End (PS AACR-F) |
Input protection |
Protected against continuous telco voltages and 100 mA over-current. Occasional ISDN over-voltages will not cause damage |
Display |
5.7 in LCD display with a projected capacitance touchscreen |
Case |
High impact plastic with show absorbing overmold |
Dimensions |
Main Versiv unit with DSX module and battery installed: 2.625 in x 5.25 in x 11.0 in (6.67 cm x 13.33 cm x 27.94 cm) |
Weight |
Main Versiv unit with DSX module and battery installed: 3 lbs, 5oz (1.28 kg) |
Main unit and remote |
Lithium ion battery pack, 7.2 V |
Typical battery life |
8 hours |
Charge time* |
Tester off: 4 hours to charge from 10 % capacity to 90 % capacity |
Languages supported |
English, French, German, Italian, Japanese, Portuguese, Spanish, Chinese, Korean, Russian, Trad Chinese, Czech, Polish, Swedish, Hungarian |
Calibration |
Service center calibration period is 1 year |
Integrated Wi-Fi |
Meets IEEE 802.11 a/b/g/n; dual band (2.4 GHz and 5 GHz) |
Fluke Networks CertiFiber Pro Optical Loss Test Set Specifications |
Power Meter Specifications |
Input Connector |
Interchangeable connector adapter (LC standard, SC, ST and FC optional) |
Detector Type |
InGaAs |
Wavelengths |
850 nm, 1300 nm, 1310 nm, 1550 nm |
Power Measurement Range |
0 dBm to -65 dBm (850 nm) 0 dBm to -70 dBm (all other wavelengths) |
Power Measurement Uncertainty1,2 |
< +/- 5% +/- 32 pW |
Measurement Linearity3 |
< ± 0.1 dB |
Re-calibration Period |
1 year |
1. +/- 100 pW at 850 nm
2. Under the following conditions: Power level 100 μW (-10 dBm), continuous wave (CW) for absolute power at 850 nm and 1310 nm. Divergent beam, NA = 0.20 for 50/125 μm and NA = 0.14 for 9/125 μm. Ambient temperature 23° ± 1°C. SC/UPC connector with ceramic ferrule. After a 5 minute warm-up. Traceable to NIST.
3. -3 dBm to -55 dBm at 850 nm and 1310 nm. Ambient temperature 23° ± 1°C. After a 5 minute warm-up. |
Loss/Length Specifications |
Specification |
CertiFiber Pro Multimode Modules |
CertiFiber Pro Singlemode Modules |
Testing Speeds (excludes referencing times) |
Smart Remote mode: < 3 seconds (2 wavelengths, one direction, auto wavelength detection)
Far End Source mode: ≤ 2 seconds (2 wavelengths, one direction auto wavelength detection)
Loopback mode: ≤ 2 seconds (2 wavelengths, one direction auto wavelength detection) |
Input/Output Connectors |
Interchangeable connector adapter (LC standard, SC, ST and FC optional) |
Launch Condition1,2 |
Encircled Flux compliant to TIA-526-14-B, ISO/IEC 14763-3 and IEC 61280-4-1 |
Fiber Types Tested |
50/125 µm or 62.5/125 µm |
singlemode |
Source Type and Wavelengths |
LED source 850 nm ± 30 nm 1300 nm ± 20 nm |
Fabry-Perot laser diode 1310 nm ± 20 nm 1550 nm ± 30 nm |
Maximum Length Measurement |
12 km |
130 km |
Length Measurement Accuracy |
± 1.5 m plus ± 1 % of length |
± 1.5 m plus ± 1 % of length |
Output Power (Nominal) |
≥ -24 dBm with EF-TRC |
≥ -4 dBm |
Output Power Stability3 |
± 0.05 dB over 8 hours ± 0.03 dB over 15 minutes |
± 0.1 dB over 8 hours ± 0.08 dB over 15 minutes |
1. At the output of the EF-TRC
2. Variations between EF measurement equipment may occur but EF compliance can be expected with a 95% confidence factor
3. Relative to power level after 15 minute warm up – at constant temperature |
Loss/Length Specifications (continued) |
Source Wavelengths |
850 nm, 1300 nm, 1310 nm, 1550 nm |
Power Measurement Range |
0 dBm to -65 dBm (850 nm) 0 dBm to -70 dBm (all other wavelengths) |
Power Measurement Uncertainty1, 2 |
< +/- 5% +/- 32 pW |
Measurement Linearity3 |
< ± 0.1 dB |
Re-calibration Period |
1 year |
1. +/- 100 pW at 850 nm
2. Under the following conditions: Power level 100 μW (-10 dBm), continuous wave (CW) for absolute power at 850 |
Selected Specifications |
Visual Fault Locator (VFL) |
Title |
Requirement |
Output Power |
>-5 dBm
<0 dBm
SMF-28 singlemode fiber
Continuous wave
SC/UPC connector |
Operating Wavelength |
650 nm nominal |
Output Modes |
Continuous wave
Pulsed mode (2 Hz to 3 Hz blink frequency) |
Connector Adapter |
2.5 mm universal |
Laser Safety |
Class II CDRH
Over operating temperature range |
Environmental Specifications |
Title |
Requirement |
Operating Temperature |
-18° C to 45° C |
Storage Temperature |
-30° C to +60° C |
Operating Relative Humidity
% RH without condensation |
0 % to 90 %, 32 °F to 95 °F (0° C to 35° C)
0 % to 70 %, 95 °F to 113 °F (35° C to 45° C) |
Vibration |
Random, 2 g, 5 Hz-500 Hz |
Shock |
1 m drop test with and without module and adapters |
Safety |
CSA C22.2 No. 1010.1: 1992
EN 61010-1 1st Edition + Amendments 1, 2 |
Pollution Degree |
2 |
Altitude |
Operating: 4,000 m; storage: 12,000 m |
EMC |
EN 61326–1 |
Product Height |
12.00 IN |
Product Length |
17.00 IN |
Product Width |
16.00 IN |
Country of Origin |
United States |
Shipping Height |
12.00 IN |
Shipping Length |
17.00 IN |
Shipping Width |
16.00 IN |
|
Reflectometers
Adapters
Reference Modules
|
|
|