Fluke Networks DSX2-5000-NW
Catalog #: 4954928
1 GHz Cable Analyzer V2 / Without W-Fi
- Overview
- Specifications
- Reflectometers
- Adapters
- Reference Modules
Product Highlights
- ONLY AVAILABLE FOR SALE TO THE US GOVERNMENT
- Includes Versiv mainframe, 1 GHz DSX Cable Analyzer
- Please Note: This model does not include Wi-Fi
- Certifies up to Cat 6A / Class FA / 1 GHz
- Versiv enables users to accomplish more than ever with a cable tester, by accelerating every step of the testing process
- Ten second Cat 6A test time contributes to fast way to gain certification
- Graphically displays the source of failures including crosstalk and distance to shield faults for faster troubleshooting
- Manage up to 12,000 Cat 6A test results with full graphics
- Capacitive touchscreen allows quick tester setup with easily selectable cable types, standards and testing parameters
- Supports the complete suite of Resistance Unbalance standards needed for Power over Ethernet (PoE) - IEEE 802.3bt, ANSI/TIA/EIA-
Each Unit Includes
- 1 Versiv Mainframe & Remote
- (2) DSX-5000 CableAnalyzer Modules
- Set of Cat 6A/Class EA Permanent Link Adapters
- Set of Cat 6A/Class EA Channel Adapters
- (2) Headsets
- (2) Hand Strap
- (2) Shoulder Straps
- Carry Case
- USB Interface Cable
- Versiv Open Source Software CD
- (2) AC Chargers
- (2) Universal Couplers
- Statement of Calibration
- Getting Started Guide
DSX CableAnalyzer Series Specifications |
Cable Types |
Shielded and unshielded pair LAN cabling |
TIA Cat 3, 4, 5, 5e, 6, 6A, 100 Ω ISO/IEC Class C, D, E, EA, F, FA and I/II: 100 Ω and 120 Ω |
Standard Link Interface Adapters |
Permanent link adapters |
Plug type: shielded RJ45
Optional Plug type: Tera |
Channel Adapters |
Jack type: shielded RJ45
Optional Jack type: Tera, GG45 |
Test Standards |
TIA |
Cat 3, 4, 5, 5e, 6, 6A, 8 per TIA 568 Series |
ISO/IEC |
Class C, D, E, EA, F, FA, I/II certification per ISO/IEC 11801 Series |
Maximum frequency |
DSX-5000 1000 MHz |
General Specifications |
Autotest Time |
DSX-5000: Full 2-way Autotest of Cat 5e or 6/Class D or E: 9 seconds Full 2-way Autotest of Cat 6A/Class EA: 10 seconds |
Support test parameters (The selected test standard determines the test parameters and the frequency range of the tests) |
Wire Map, Length, Propagation Delay, Delay Skew, DC Loop Resistance, Insertion Loss (Attenuation), Return Loss (RL), NEXT, Attenuation-tocrosstalk Ratio (ACR-N), ACR-F (ELFEXT), Power Sum ACR-F (ELFEXT), Power Sum NEXT, Power Sum ACR-N, Power Sum Alien Near End Xtalk (PS ANEXT), Power Sum Alien Attenuation Xtalk Ratio Far End (PS AACR-F) |
Input protection |
Protected against continuous telco voltages and 100 mA over-current. Occasional ISDN over-voltages will not cause damage |
Display |
5.7 in LCD display with a projected capacitance touchscreen |
Case |
High impact plastic with show absorbing overmold |
Dimensions |
Main Versiv unit with DSX module and battery installed: 2.625 in x 5.25 in x 11.0 in (6.67 cm x 13.33 cm x 27.94 cm) |
Weight |
Main Versiv unit with DSX module and battery installed: 3 lbs, 5oz (1.28 kg) |
Main unit and remote |
Lithium ion battery pack, 7.2 V |
Typical battery life |
8 hours |
Charge time* |
Tester off: 4 hours to charge from 10 % capacity to 90 % capacity |
Languages supported |
English, French, German, Italian, Japanese, Portuguese, Spanish, Chinese, Korean, Russian, Trad Chinese, Czech, Polish, Swedish, Hungarian |
Calibration |
Service center calibration period is 1 year |
Integrated Wi-Fi |
Meets IEEE 802.11 a/b/g/n; dual band (2.4 GHz and 5 GHz) |
|
Reflectometers
Adapters
Reference Modules
|