|
|
Fluke Calibration 5618B-9-B
Catalog #: 3003400
Secondary PRT Probe, 9 X 1/8 INCH OD
- Overview
- Specifications
- Summary
- Cases
Product Highlights
- 5618B-9-B (bare wire)
- 229 mm (9 in)
- Small diameter sheath, 3.2mm (0.125 in)
- Excellent stability
- Includes ITS-90 coefficients
- NVLAP-accredited calibrated from –200°C to 500°C, lab code 200706-0
Each Unit Includes
- Coefficient Sheet
- User Manual CD
- Certification Sheets
Specifications |
Resistance |
Nominal 100 Ω at 0 °C |
Temperature Coefficient |
0.003923 Ω/Ω/ °C nominal |
Temperature Range |
–200 °C to 500 °C
(–200 °C to 300 °C for 5618B-6-X) |
Drift Rate |
± 0.1 °C when used periodically to 500 °C |
Sheath Material |
316 SST |
Leads |
22 AWG PTFE, 6’ |
Termination |
Specify |
Hysteresis |
Less than 0.01 °C at 0 °C when using –196 °C and 420 °C as the end points. |
Time Constant |
Four seconds maximum for 63.2 % response to step change in water moving at 3 fps |
Thermal EMF |
Less than 25 mV at 420 °C |
Calibration |
Includes manufacturer’s NVLAP-accredited Calibration w/ ITS-90 coefficients, R vs. T values in 1 °C increments, lab code 200706-0 |
Size |
: 305 mm L x 3.2 mm dia. (12 x 1/8 in)
: 229 mm L x 3.2 mm dia. (9 x 1/8 in)
: 152 mm L x 3.2 mm dia. (6 x 1/8 in) |
Calibrated Accuracy† (k=2) |
± 0.026 °C at –200 °C
± 0.066 °C at 0 °C
± 0.219 °C at 500 °C |
†Includes calibration uncertainty and drift specification |
NVLAP† Calibration Uncertainty |
Temperature |
Expanded Uncertainty (k=2) |
–38 °C |
0.011 °C |
0 °C |
0.010 °C |
200 °C |
0.018 °C |
420 °C‡ |
0.029 °C |
Note: Calibration uncertainties depend on the uncertainties of the lab performing the calibration. Subsequent calibrations of this probe performed with different processes, at different facilities, or with changed uncertainty statements may state different uncertainties. †Lab code 200706-0 ‡300 °C for 5618B-6 |
|
Accessories/Probes/Temperature Probes Template |
Application/Properties |
Gas/Air, General, Immersion, Piercing, Pipe, Surface |
Max Temperature |
500 C |
Min Temperature |
-200 C (-328 F) |
Wire Termination |
Bare Wire |
Insulation Material |
Stainless Steel |
Probe Length |
9 IN |
Lead Length |
72 IN (25.40 MM) |
Unique Features |
Resistance Nominal 100 Ω at 0 °C
Temperature Coefficient 0.003923 Ω/Ω/ °C nominal
Temperature Range –200 °C to 500 °C
(–200 °C to 300 °C for 5618B-6-X)
Drift Rate ± 0.1 °C when used periodically to 500 °C
Sheath Material 316 SST
Leads 22 AWG PTFE, 6’
Termination Specify
Hysteresis Less than 0.01 °C at 0 °C when using –196 °C and 420 °C as the end points.
Time Constant Four seconds maximum for 63.2 % response to step change in water moving at 3 fps. |
Warranty |
1 YEARS |
Additional Info/Comments |
Thermal EMF Less than 25 mV at 420 °C
Calibration
Includes manufacturer’s NVLAP-accredited
calibration w/ITS-90 coefficients, R vs. T values in
1 °C increments, lab code 200706-0
Size
5618B-12: 305 mm L x 3.2 mm dia. (12 x 1/8 in)
5618B-9: 229 mm L x 3.2 mm dia. (9 x 1/8 in)
5618B-6: 152 mm L x 3.2 mm dia. (6 x 1/8 in)
Calibrated Accuracy† (k=2)
± 0.026 °C at –200 °C
± 0.066 °C at 0 °C
± 0.219 °C at 500 °C |
Calibration Included |
NIST Calibration |
Data Logging |
No |
Interfaces I/O |
Other |
Product Weight |
7.94 LBS |
Product Height |
7.99 IN |
Product Length |
24.02 IN |
Product Width |
12.01 IN |
Shipping Weight |
8.73 LBS |
ECCN Number |
3A992 |
Country of Origin |
United States |
Shipping Height |
3.15 IN |
Shipping Length |
20.87 IN |
Shipping Width |
11.02 IN |
UPC |
095969402989 |
|
|
|
|