Our search by product feature is currently under construction. Please search by manufacturer or using the site search bar. We apologize for the inconvenience. Should you have any questions please feel free to contact us at sales@usamultimeters.com or by calling 888-315-6773
Fluke Calibration 5618B-12-P
Catalog #: 3376977
Secondary PRT Probe, 12 X 1/8 INCH OD, P = INFO-CON for 1523 or 1524

  • Overview
  • Specifications
  • Summary
  • Cases

Product Highlights

  • 5618B-12-P (INFO-CON for 1523 or 1524)
  • 305 mm (12 in)
  • Small diameter sheath, 3.2mm (0.125 in)
  • Excellent stability
  • Includes ITS-90 coefficients
  • NVLAP-accredited calibrated from –200°C to 500°C, lab code 200706-0

Each Unit Includes

  • Coefficient Sheet
  • User Manual CD
  • Certification Sheets

 

Specifications
Resistance Nominal 100 Ω at 0 °C
Temperature Coefficient 0.003923 Ω/Ω/ °C nominal
Temperature Range –200 °C to 500 °C
(–200 °C to 300 °C for 5618B-6-X)
Drift Rate ± 0.1 °C when used periodically to 500 °C
Sheath Material 316 SST
Leads 22 AWG PTFE, 6’
Termination Specify
Hysteresis Less than 0.01 °C at 0 °C when using –196 °C and 420 °C as the end points.
Time Constant Four seconds maximum for 63.2 % response to step change in water moving at 3 fps
Thermal EMF Less than 25 mV at 420 °C
Calibration Includes manufacturer’s NVLAP-accredited Calibration w/ ITS-90 coefficients, R vs. T values in 1 °C increments, lab code 200706-0
Size : 305 mm L x 3.2 mm dia. (12 x 1/8 in)
: 229 mm L x 3.2 mm dia. (9 x 1/8 in)
: 152 mm L x 3.2 mm dia. (6 x 1/8 in)
Calibrated Accuracy† (k=2) ± 0.026 °C at –200 °C
± 0.066 °C at 0 °C
± 0.219 °C at 500 °C
†Includes calibration uncertainty and drift specification
NVLAP† Calibration Uncertainty
Temperature Expanded Uncertainty (k=2)
–38 °C 0.011 °C
0 °C 0.010 °C
200 °C 0.018 °C
420 °C‡ 0.029 °C
Note: Calibration uncertainties depend on the uncertainties of the lab performing the calibration. Subsequent calibrations of this probe performed with different processes, at different facilities, or with changed uncertainty statements may state different uncertainties. †Lab code 200706-0 ‡300 °C for 5618B-6

 

Fluke Calibration Platinum Resistance Thermometers (PRTs)
Model Range Size Basic Accuracy† 
Platinum Resistance Thermometer: Secondary Standard PRT
5608-9-X –200 to 500 °C 9 in x 1/8 in Select from available calibration options
5608-12-X –200 to 500 °C 12 in x 1/8 in
5609-12-X –200 to 670 °C 12 in x 1/4 in
5609-15-X –200 to 670 °C 15 in x 1/4 in
5609-20-X –200 to 670 °C 20 in x 1/4 in
5609-300-X –200 to 670 °C 300 mm x 6 mm
5609-400-X –200 to 670 °C 400 mm x 6 mm
5609-500-X –200 to 670 °C 500 mm x 6 mm
5626 –200 °C to 661 °C 305 or 381 x 6.35 mm (12 or 15 x 0.25 in ±0.007 °C at 0 °C
Platinum Resistance Thermometer: Secondary Reference PRT
5616-12 –200 °C to 420 °C 6.35 mm x 298 mm (0.250 x 11.75 in) ± 0.010 °C at 0.010 °C
5615-6  –200 to 300 °C 4.76 mm x 152 mm (0.188 x 6.0 in) ± 0.013 °C at 0.010 °C
5615-9 –200 °C to 420 °C 4.76 mm x 229 mm (0.188 x 9.0 in) ± 0.013 °C at 0.010 °C
>5615-12 –200 °C to 420 °C 6.35 mm x 305 mm (0.250 x 12.0 in) ± 0.013 °C at 0.010 °C
Platinum Resistance Thermometer: Precision Industrial PRT
5627A-6 –200 °C to 300 °C 152 x 4.7 mm (6 x 0.187 in) ±0.05 °C at 0 °C
5627A-9 –200 °C to 300 °C 229 x 4.7 mm (9 x 0.187 in) ±0.05 °C at 0 °C
5627A-12 –200 °C to 420 °C 305 x 6.35 mm (12 x 0.25 in) ±0.05 °C at 0 °C
Platinum Resistance Thermometer: Fast Response PRT
>5622-05 –200 °C to 350 °C 100 x 0.5 mm ±0.04 °C at 0 °C
>5622-10 –200 °C to 350 °C 100 x 1.0 mm ±0.04 °C at 0 °C
>5622-16 –200 °C to 350 °C 200 x 1.6 mm ±0.04 °C at 0 °C
>5622-32 –200 °C to 350 °C 200 x 3.2 mm ±0.04 °C at 0 °C
Platinum Resistance Thermometer: Small Diameter Industrial PRTs
5618B-6 –200 °C to 300 °C 152 x 3.2 mm (6 x 0.125 in) ±0.05 °C
5618B-9 –200 °C to 500 °C 229 x 3.2 mm (9 x 0.125 in) ±0.05 °C
5618B-12 –200 °C to 500 °C 305 x 3.2 mm (12 x 0.125 in) ±0.05 °C
Platinum Resistance Thermometer: Full Immersion PRTs
5606 Immersion PRT –200 to 160 °C 50 x 3.1 mm ( 2 x 1/8 in) ±0.05 °C
5607 Immersion PRT 0 to 450 °C 75 x 3.1 mm (3 x 1/8 in) ±0.055 °C
5623B Freezer Probe  –100 °C to 156 °C 152 x 6.35 mm (6 x 0.25 in)  ±0.05 °C 
Thermistors
Thermistor: Standards
5640 0 °C to 60 °C 229 x 6.35 mm (9 x 0.25 in) ±0.0015 °C
5641 0 °C to 60 °C 114 x 3.2 mm (4.5 x 0.125 in) ±0.001 °C
5642 0 °C to 60 °C 229 x 3.2 mm (9 x 0.125 in) ±0.001 °C
5643 0 °C to 100 °C 114 x 3.2 mm (4.5 x 0.125 in) ±0.0025 °C
5644 0 °C to 100 °C 229 x 3.2 mm (9 x 0.125 in) ±0.0025 °C
Thermistor: Secondary Probes
5610 0 °C to 100 °C 152 or 229 x 3.2 mm (6 or 9 x 0.125 in) ±0.01 °C
5611A 0 °C to 100 °C 1.5 mm  (0.06 in) tip dia. ±0.01 °C
5611T 0 °C to 100 °C 28 x 3 mm (1.1 x 0.12 in) ±0.01 °C
†“Basic Accuracy” includes calibration uncertainty and short-term repeatability. It does not include long-term drift.

X = termination. Specify A (INFO-CON for 914X), B (bare wire), D (5-pin DIN for Tweener Thermometers), G (gold pins), I (INFO-CON for 1521 or 1522), J (banana plugs), L (mini spade lugs), M (mini banana plugs), P (INFO-CON for 1523 or 1524), or S (spade lugs).

 

Accessories/Probes/Temperature Probes Template
Application/Properties Gas/Air, General, Immersion, Piercing, Pipe, Surface
Max Temperature 500 C
Min Temperature -200 C (-328 F)
Wire Termination Other 
Insulation Material Stainless Steel
Probe Length 12 IN
Lead Length 72 IN (25.40 MM)
Unique Features Resistance Nominal 100 Ω at 0 °C 

Temperature Coefficient 0.003923 Ω/Ω/ °C nominal

Temperature Range –200 °C to 500 °C

(–200 °C to 300 °C for 5618B-6-X) 

Drift Rate ± 0.1 °C when used periodically to 500 °C 

Sheath Material 316 SST 

Leads 22 AWG PTFE, 6’ 

Termination Specify 

Hysteresis Less than 0.01 °C at 0 °C when using –196 °C and 420 °C as the end points. 

Time Constant Four seconds maximum for 63.2 % response to step change in water moving at 3 fps.
Warranty 1 YEARS
Additional Info/Comments Thermal EMF Less than 25 mV at 420 °C 

Calibration

Includes manufacturer’s NVLAP-accredited

calibration w/ITS-90 coefficients, R vs. T values in

1 °C increments, lab code 200706-0 

Size

5618B-12: 305 mm L x 3.2 mm dia. (12 x 1/8 in)

5618B-9: 229 mm L x 3.2 mm dia. (9 x 1/8 in)

5618B-6: 152 mm L x 3.2 mm dia. (6 x 1/8 in) 

Calibrated Accuracy† (k=2)

± 0.026 °C at –200 °C

± 0.066 °C at 0 °C

± 0.219 °C at 500 °C
Calibration Included NIST Calibration 
Data Logging  No
Interfaces I/O Other
Product Weight 7.94 LBS
Product Height 7.99 IN
Product Length 24.02 IN
Product Width 12.01 IN
Shipping Weight 8.73 LBS
ECCN Number 3A992
Country of Origin United States
Shipping Height 3.15 IN
Shipping Length 20.87 IN
Shipping Width 11.02 IN
UPC 095969482332
MEMBER PRICE: INACTIVE
List price:   $1,669.24
Notify me when price changes $

Related products

Cases

Recently viewed products

We Ship Worldwide
Australia
Write us quote request in any language and then immediately translate it to English on our site.
Brazil
Envíenos su solicitud en cualquier idioma, que luego se traducen automáticamente en Inglés en nuestro sitio web.
Chile
Envíenos su solicitud en cualquier idioma, que luego se traducen automáticamente en Inglés en nuestro sitio web.
China
您的要求发送给我们以任何语言,它会自动翻译成英文在我们的网站。
France
Envoyez-nous votre demande dans n'importe quelle langue, qui seront ensuite automatiquement traduites en anglais sur notre site.
Germany
Schreiben Sie uns Ihre Anfrage in jeder beliebigen Sprache, diese wird dann auf unserer Website automatisch ins englische übersetzt.
India
हमें किसी भी भाषा में आपके अनुरोध है, जो स्वचालित रूप से हमारी वेबसाइट पर अंग्रेजी में अनुवाद हो जाएगा भेजें.
Italy
Inviaci la tua richiesta in qualsiasi lingua, che sarà automaticamente tradotto in inglese sul nostro sito web.
Japan
任意の言語で、その後は自動的に英語に当社のウェブサイト上に翻訳されますあなたのリクエストを送ってください。
Mexico
Envíenos su solicitud en cualquier idioma, que luego se traducen automáticamente en Inglés en nuestro sitio web.
Norway
Send oss din forespørsel på alle språk, som deretter automatisk oversatt til engelsk på våre nettsider.
Philippines
Ipadala sa amin ang inyong kahilingan sa kahit anong wika, na awtomatikong masasalin sa Ingles sa aming website.
Portugal
Envíenos su solicitud en cualquier idioma, que luego se traducen automáticamente en Inglés en nuestro sitio web.
Russian Federation
Отправьте нам свой запрос на любом языке, который будет автоматически переведен на английский на нашем сайте.
Spain
Envíenos su solicitud en cualquier idioma, que luego se traducen automáticamente en Inglés en nuestro sitio web.
United Kingdom
Write us quote request in any language and then immediately translate it to English on our site.
Quote Request
Portuguese Spanish German Hindi Italian Russian
English
Write us quote request in any language and then immediately translate it to English on our site
We Accept Payments
Usamultimeters.com BBB Business Review
Copyright © 2008-2024 usamultimeters.com All Rights Reserved
Products Manufactures Quote Request Resources Cart