Fluke Calibration 5618B-12-G
Catalog #: 3003269
Secondary PRT Probe, 12 X 1/8 INCH OD, G = Gold Pins
- Overview
- Specifications
- Summary
- Cases
Product Highlights
- Small diameter sheath, 3.2mm (0.125 in)
- Excellent stability
- Includes ITS-90 coefficients
- NVLAP-accredited calibrated from –200°C to 500°C, lab code 200706-0
Each Unit Includes
- Coefficient Sheet
- User Manual CD
- Certification Sheets
Specifications |
Resistance |
Nominal 100 Ω at 0 °C |
Temperature
Coefficient |
0.003923 Ω/Ω/ °C nominal |
Temperature
Range |
–200 °C to 500 °C
(–200 °C to 300 °C for 5618B-6-X) |
Drift Rate |
± 0.1 °C when used periodically to 500 °C |
Sheath Material |
316 SST |
Leads |
22 AWG PTFE, 6’ |
Termination |
Specify |
Hysteresis |
Less than 0.01 °C at 0 °C when using –196 °C and
420 °C as the end points. |
Time Constant
|
Four seconds maximum for 63.2 % response to
step change in water moving
at 3 fps. |
Thermal EMF |
Less than 25 mV at 420 °C |
Calibration
|
Includes manufacturer’s NVLAP-accredited
calibration w/ITS-90 coefficients, R vs. T values in
1 °C increments, lab code 200706-0 |
Size
|
5618B-12: 305 mm L x 3.2 mm dia. (12 x 1/8 in)
5618B-9: 229 mm L x 3.2 mm dia. (9 x 1/8 in)
5618B-6: 152 mm L x 3.2 mm dia. (6 x 1/8 in) |
Calibrated
Accuracy† (k=2) |
± 0.026 °C at –200 °C
± 0.066 °C at 0 °C
± 0.219 °C at 500 °C |
†Includes
calibration
uncertainty and
drift specification. |
NVLAP† Calibration Uncertainty |
Temperature |
Expanded Uncertainty (k=2) |
–196 °C |
0.024 °C |
–38 °C |
0.011 °C |
0 °C |
0.010 °C |
200 °C |
0.018 °C |
420 °C‡ |
0.029 °C |
Note: Calibration uncertainties depend on the uncertainties of the lab performing the calibration. Subsequent calibrations of this probe performed with different processes, at different facilities, or with changed uncertainty statements may state different uncertainties. †Lab code 200706-0 ‡300 °C for 5618B-6 |
|
Fluke Calibration Platinum Resistance Thermometers (PRTs) |
Model |
Range |
Size |
Basic Accuracy† |
Platinum Resistance Thermometer: Secondary Standard PRT |
5608-9-X |
–200 to 500 °C |
9 in x 1/8 in |
Select from available calibration options |
5608-12-X |
–200 to 500 °C |
12 in x 1/8 in |
5609-12-X |
–200 to 670 °C |
12 in x 1/4 in |
5609-15-X |
–200 to 670 °C |
15 in x 1/4 in |
5609-20-X |
–200 to 670 °C |
20 in x 1/4 in |
5609-300-X |
–200 to 670 °C |
300 mm x 6 mm |
5609-400-X |
–200 to 670 °C |
400 mm x 6 mm |
5609-500-X |
–200 to 670 °C |
500 mm x 6 mm |
5626 |
–200 °C to 661 °C |
305 or 381 x 6.35 mm (12 or 15 x 0.25 in |
±0.007 °C at 0 °C |
Platinum Resistance Thermometer: Secondary Reference PRT |
5616-12 |
–200 °C to 420 °C |
6.35 mm x 298 mm (0.250 x 11.75 in) |
± 0.010 °C at 0.010 °C |
5615-6 |
–200 to 300 °C |
4.76 mm x 152 mm (0.188 x 6.0 in) |
± 0.013 °C at 0.010 °C |
5615-9 |
–200 °C to 420 °C |
4.76 mm x 229 mm (0.188 x 9.0 in) |
± 0.013 °C at 0.010 °C |
>5615-12 |
–200 °C to 420 °C |
6.35 mm x 305 mm (0.250 x 12.0 in) |
± 0.013 °C at 0.010 °C |
Platinum Resistance Thermometer: Precision Industrial PRT |
5627A-6 |
–200 °C to 300 °C |
152 x 4.7 mm (6 x 0.187 in) |
±0.05 °C at 0 °C |
5627A-9 |
–200 °C to 300 °C |
229 x 4.7 mm (9 x 0.187 in) |
±0.05 °C at 0 °C |
5627A-12 |
–200 °C to 420 °C |
305 x 6.35 mm (12 x 0.25 in) |
±0.05 °C at 0 °C |
Platinum Resistance Thermometer: Fast Response PRT |
>5622-05 |
–200 °C to 350 °C |
100 x 0.5 mm |
±0.04 °C at 0 °C |
>5622-10 |
–200 °C to 350 °C |
100 x 1.0 mm |
±0.04 °C at 0 °C |
>5622-16 |
–200 °C to 350 °C |
200 x 1.6 mm |
±0.04 °C at 0 °C |
>5622-32 |
–200 °C to 350 °C |
200 x 3.2 mm |
±0.04 °C at 0 °C |
Platinum Resistance Thermometer: Small Diameter Industrial PRTs |
5618B-6 |
–200 °C to 300 °C |
152 x 3.2 mm (6 x 0.125 in) |
±0.05 °C |
5618B-9 |
–200 °C to 500 °C |
229 x 3.2 mm (9 x 0.125 in) |
±0.05 °C |
5618B-12 |
–200 °C to 500 °C |
305 x 3.2 mm (12 x 0.125 in) |
±0.05 °C |
Platinum Resistance Thermometer: Full Immersion PRTs |
5606 Immersion PRT |
–200 to 160 °C |
50 x 3.1 mm ( 2 x 1/8 in) |
±0.05 °C |
5607 Immersion PRT |
0 to 450 °C |
75 x 3.1 mm (3 x 1/8 in) |
±0.055 °C |
5623B Freezer Probe |
–100 °C to 156 °C |
152 x 6.35 mm (6 x 0.25 in) |
±0.05 °C |
Thermistors |
Thermistor: Standards |
5640 |
0 °C to 60 °C |
229 x 6.35 mm (9 x 0.25 in) |
±0.0015 °C |
5641 |
0 °C to 60 °C |
114 x 3.2 mm (4.5 x 0.125 in) |
±0.001 °C |
5642 |
0 °C to 60 °C |
229 x 3.2 mm (9 x 0.125 in) |
±0.001 °C |
5643 |
0 °C to 100 °C |
114 x 3.2 mm (4.5 x 0.125 in) |
±0.0025 °C |
5644 |
0 °C to 100 °C |
229 x 3.2 mm (9 x 0.125 in) |
±0.0025 °C |
Thermistor: Secondary Probes |
5610 |
0 °C to 100 °C |
152 or 229 x 3.2 mm (6 or 9 x 0.125 in) |
±0.01 °C |
5611A |
0 °C to 100 °C |
1.5 mm (0.06 in) tip dia. |
±0.01 °C |
5611T |
0 °C to 100 °C |
28 x 3 mm (1.1 x 0.12 in) |
±0.01 °C |
†“Basic Accuracy” includes calibration uncertainty and short-term repeatability. It does not include long-term drift.
X = termination. Specify A (INFO-CON for 914X), B (bare wire), D (5-pin DIN for Tweener Thermometers), G (gold pins), I (INFO-CON for 1521 or 1522), J (banana plugs), L (mini spade lugs), M (mini banana plugs), P (INFO-CON for 1523 or 1524), or S (spade lugs). |
Country of Origin |
United States |
|
|
|
|