Display: 4 ¾ digit liquid crystal display (LCD) with a 41 segment analog bargraphic.
Auto ranging: 9999 counts
Manual ranging: 9999 counts
Polarity: Automatic, positive implied, negative polarity indication.
Overrange: (OL) or (-OL) is displayed.
Zero: Automatic.
Low battery indication: The indicator is displayed when the battery voltage drops below the operating level.
Auto power off: Approx. 30 minutes.
Measurement rate: 2 times per second, nominal.
Operating environment: 0 ºC to 50 ºC at 70 % R.H.
Storage temperature: -20 ºC to 60 ºC, 0 to 80 % R.H. with battery removed from meter.
Temperature Coefficient: 0.1 x (specified accuracy) per ºC. (0 ºC to 18 ºC, 28 ºC to 50 ºC).
Altitude: (2000 m) 6562 feet
Power: Single standard 9-volt battery, NEDA 1604, JIS 006P, IEC 6F22.
Battery life: 75 hours typical with carbon-zinc. 150 hours typical with alkaline. Using the backlight will decrease battery life.
Dimensions: 196 mm (H) x92 mm (W) x60 mm (D).
Weight: with battery and holster, 482 grams
DC Voltage Ranges: 1000 mV, 10 V, 100 V, 1000 V
DC Voltage Accuracy: all ranges ± (0.1 % rdg + 5 dgt)
DC Voltage Resolution: 100 µV
AC Voltage (45 Hz to 2 kHz) True RMS Ranges: 1000 mV, 10 V, 100 V, 750 V
AC Voltage (45 Hz to 2 kHz) True RMS Accuracy: 750 V range: 45 to 1 kHz: ± (2.0 % rdg + 10 dgts)
AC Voltage (45 Hz to 2 kHz) True RMS Accuracy: All other ranges, 45 to 500 Hz: ± (1.2 % rdg + 10 dgts)
AC Voltage (45 Hz to 2 kHz) True RMS Accuracy: All other ranges, 500 to 2 kHz: ± (2.0 % rdg + 10 dgts)
AC Voltage (45 Hz to 2 kHz) True RMS Resolution: 100 µV
AC coupled: True RMS specified from 5 % to 100 % of range
DC Current Ranges: 100 µ, 1000 µ, 10 mA, 100 mA, 400 mA, 10 A
DC Current Accuracy: 100 µ range: ± (0.5 % rdg + 10 dgt)
DC Current Accuracy: 1000 uA to 400 mA ranges: ± (0.5 % rdg + 5 dgts)
DC Current Accuracy: 10 A range: ± (1.5 % rdg + 10 dgt)
DC Current Resolution: 0.01 µA
AC Current (45 Hz to 1 kHz) True RMS Ranges: 100 µA, 1000 µA, 10 mA, 100 mA, 400 mA, 10 A
AC Current (45 Hz to 1 kHz) True RMS Accuracy: 100 µ to 100 mA ranges: ± (1.5 % rdg + 10 dgts)
AC Current (45 Hz to 1 kHz) True RMS Accuracy: 400 mA range: ± (2.0 % rdg + 10 dgts)
AC Current (45 Hz to 1 kHz) True RMS Accuracy: 10 A range: ± (2.5 % rdg + 10 dgts)
AC Current (45 Hz to 1 kHz) True RMS Resolution: 0.01 µA
Resistance Ranges: 1000 ? 10 k? 100 k? 1000 k? 10 M? 40 M?
Resistance Accuracy: 1000 ? to 1000 k? ranges: ± (0.5 % rdg + 8 dgts)
Resistance Accuracy: 10 M? range: ± (1.0 % rdg + 10 dgts)
Resistance Accuracy: 40 M? range: ± (2.0 % rdg + 10 dgts)
Logic Test , Logic Type: TTL, CMOS
|