             Display: 4? digit liquid crystal display (LCD)(9999 count) with a 41-segment analogbar-graph. 
            Auto ranging: 9999 counts 
            Manual ranging: 9999 counts 
            Polarity: Automatic, positive implied, negative polarity indication. 
            Overrange: 0o or -0o is displayed. 
            Zero: Automatic. 
            Low battery indication: The B symbol is displayed when the battery voltage drops below the operating level. 
            Auto power off: Approx. 30 minutes. 
            Measurement rate: 2 times per second, nominal. 
            Operating environment: 0 ?C to 50 ?C at 70 % R.H. 
            Storage temperature: -20 ?C to 60 ?C, 0 to 80 % R.H. with battery removed from meter. 
            Temperature Coefficient: 0.1 ? (specified accuracy) per ?C. (0 ?C to18 ?C, 28 ?C to 50 ?C). 
            Altitude: 2000 m (6562 feet) 
            Power: Single standard 9-volt battery, NEDA 1604, JIS 006P, IEC 6F22. 
            Battery life: 75 hours typical with carbon-zinc. 150 hours typical with alkaline. 
            Dimensions: 196 mm (H) ?96 mm (W)?60 mm (D) 
            Warranty: 3 Year 
            Battery Life: 150 hrs typical (alkaline) 
            Size: 7.75" x 3.55" x 2.4" (195 x 92 x 60 mm) 
            Weight: (without holster, including battery): 1 lb (400 gr) 
            Safety: Cat II 1000V, Cat IV 600V 
            Ranges: 1000 mV, 10 V, 100 V, 1000 V ( auto/manual ranging ) 
            Resolution: 100 µV 
            Accuracy: ?(0.25 % rdg + 5 dgts) 
            Input impedance: 10 MO 
            Overload protection: 1000 V dc or 750 V ac rms 
            Ranges: 1000 mV, 10 V, 100 V, 750 V (auto/manual ranging) 
            Resolution: 100 µV 
            Accuracy: ?(1.2 % rdg + 10 dgts) 45 Hz to 500 Hz 
            ?(2.0 % rdg + 10 dgts) 500 Hz to 2 kHz 
            ?(2.0 % rdg + 10 dgts) 45 Hz to 1 kHz on 750 V range 
            Peak Hold accuracy: ?(3.0 % + 200 dgts) on 100 V, 750 V range; 1000 mV, 10 V ranges unspecified 
            DC Voltage Ranges: 1000 mV, 10 V, 100 V, 1000 V 
            DC Voltage Accuracy: all ranges ? (0.25 % rdg + 5 dgt) 
            DC Voltage Resolution: 100 µV 
            AC Voltage (45 Hz to 2 kHz) True RMS Ranges: 1000 mV, 10 V, 100 V, 750 V 
            AC Voltage (45 Hz to 2 kHz) True RMS Accuracy: 750 V range: 45 to 1 kHz: ? (2.0 % rdg + 10 dgts) 
            AC Voltage (45 Hz to 2 kHz) True RMS Accuracy: All other ranges, 45 to 500 Hz: ? (1.2 % rdg + 10 dgts) 
            AC Voltage (45 Hz to 2 kHz) True RMS Accuracy: All other ranges, 500 to 2 kHz: ? (2.0 % rdg + 10 dgts) 
            AC coupled: True RMS specified from 5 % to 100 % of range 
            AC + DC Voltage (45 Hz to 2 kHz): 1000 mV, 10 V, 100 V, 750 V 
            DC Current Ranges: 100 µA, 1000 µA, 10 mA, 100 mA, 400 mA, 10 A 
            DC Current Accuracy: 100 µA range: ? (0.5 % rdg + 10 dgt) 
            DC Current Accuracy: 1000 uA to 400 mA ranges: ? (0.5 % rdg + 5 dgts) 
            DC Current Accuracy: 10 A range: ? (1.5 % rdg + 10 dgt) 
            DC Current Resolution: 0.01 µA 
            AC Current (True RMS) ( AC + DC) (45 Hz ? 1kHz) Ranges: 100 µA, 1000 µA, 10 mA, 100 mA, 400 mA, 10 A 
            AC Current (True RMS) ( AC + DC) (45 Hz ? 1kHz) Accuracy: 100 µA to 100 mA ranges: ? (1.5 % rdg + 10 dgts) 
            AC Current (True RMS) ( AC + DC) (45 Hz ? 1kHz) Accuracy: 400 mA range: ? (2.0 % rdg + 10 dgts) 
            AC Current (True RMS) ( AC + DC) (45 Hz ? 1kHz) Accuracy: 10 A range: ? (2.5 % rdg + 10 dgts) 
            AC Current (45 Hz to 1 kHz) True RMS Resolution: 0.01 µA 
            Resistance Ranges: 1000 ? 10 k? 100 k? 1000 k? 10 M? 40 M? 
            Resistance Accuracy: 1000 ? to 1000 k? ranges: ? (0.5 % rdg + 8 dgts) 
            Resistance Accuracy: 10 M? range: ? (1.0 % rdg + 10 dgts) 
            Resistance Accuracy: 40 M? range: ? (2.0 % rdg + 10 dgts) 
             |