Amprobe 33XR-A
Catalog #: 2727788
Manual Ranging Digital Multimeter, 1000VDC/750VAC with Temperature and Capacitance
Product Highlights
- Frequency To 40 MHz, Temperature To 1832 F, Capacitance To 4000 microF
- Input Warning Tone When Test Leads Are In Wrong Jack
- 1000V/750V DC/AC
- 10 Amps AC/DC. Fully Safety Fused
- Resistance To 4ohm
- Min/max, relative, peak and data hold
- Auto power off to save battery life
- Separate door for easy battery and fuse access
- Magne-Grip Holster with magnetic hanging strap
- Display: 3-3/4 digit LCD, 3999 counts with 41-segment analog bar graph
- Display update rate: 2/sec, nominal
- Analog bar graph
- Overrange indication
- Operating temperature: 0 °C to 45 °C at < 70 % R.H.
- Storage temperature: -20 °C to 60 °C,
- Input warning tone when test leads are in wrong jack
Each Unit Includes
- 1 - Set of Test leads with threaded alligator clips (TL36A)
- 1 - 9V Battery (installed)
- 1 - Magne-Grip Holster with magnetic hanging strap
- 1 - Temperature Adapter (TA-1)
- 1 - Type K thermocouple probe (TP255A)
- 1 - Spare fuse
- 1 - Users Manual
Display |
3 ¾ digit liquid crystal display (LCD)(3999 count) with a 41-segment analog bar-graph. |
Polarity |
Automatic, positive implied, negative polarity indication. |
Overrange |
(o) or (-o) is displayed. |
Zero |
Automatic. |
Low battery indication |
The B is displayed when the battery voltage drops below the operating level. |
Auto power off |
Approximately 30 minutes. |
Measurement rate |
2 times per second, nominal. |
Operating environment |
0 °C to 50 °C at <70 % R.H. |
Storage temperature |
-20 °C to 60 °C, 0 to 80 % R.H. with battery removed from meter. |
Temperature Coefficient |
0.1 ?? (specified accuracy) per °C.
(0 °C to 18 °C, 28 °C to 50 °C). |
Environment |
Indoor use, altitude up to 2000 m |
Power |
Single standard 9-volt battery, NEDA 1604, JIS 006P, IEC 6F22. |
Battery life |
150 hours typical with carbon-zinc.
300 hours typical with alkaline. |
Dimensions |
196 mm (H) x 92 mm (W) x 60 mm (D). |
Weight |
Approximately 400 g including battery. |
Warranty |
One-Year |
Battery Life |
300 hrs typical (alkaline) |
Size |
7.7" x 3.5" x 2.3" (196 x 92 x 60 mm) |
Safety |
Cat II 1000V, Cat III 600V |
Electrical Specifications |
DC Voltage Ranges |
400 mV, 4 V, 40 V, 400 V, 1000 V |
DC Voltage Accuracy |
all ranges: ± (0.7 % rdg + 1 dgt) |
DC Voltage Resolution |
100 µV |
DC Voltage Input Impedance |
10 Mω |
AC Voltage (45 Hz to 500 Hz) Ranges |
400 mV, 4 V, 40 V, 400 V, 750 V |
AC Voltage (45 Hz to 500 Hz) Accuracy |
4 V Range, 200 Hz to 500 Hz: ± (2.0 % rdg + 4 dgts) |
AC Voltage (45 Hz to 500 Hz) Accuracy |
All other ranges: ± (1.5 % rdg + 4 dgts) |
AC Voltage (45 Hz to 500 Hz) Resolution |
100 µV |
AC Voltage (45 Hz to 500 Hz) Input Impedance |
10 Mω |
DC Current Ranges |
400 µA, 4 mA, 40 mA, 300 mA, 10 A |
DC Current Accuracy |
400 µA to 300 mA ranges: ± (1.0 % rdg + 1 dgt) |
DC Current Accuracy |
10 A range: ± (2.0 % rdg + 3 dgts) |
DC Current Resolution |
0.1 µA |
DC Current Voltage Burden |
400 µA range: 1 mV/µA, 4 mA range: 100 mV/1 mA, 40 mA range: 12 mV/1 mA, |
DC Current Voltage Burden |
300 mA range: 4 mV/1 mA, 10 A range: 100 mV/1 A |
AC Current (45 Hz to 500 Hz) Ranges |
400 µA, 4 mA, 40 mA, 300 mA, 10 A |
AC Current (45 Hz to 500 Hz) Accuracy |
400 µA to 300 mA ranges: ± (1.5 % rdg + 4 dgts) |
AC Current (45 Hz to 500 Hz) Accuracy |
10 A range: ± (2.5 % rdg + 4 dgts) AC Current (45 Hz to 500 Hz) Resolution: 0.1 µA |
AC Current (45 Hz to 500 Hz) Voltage Burden |
See DC Current |
Resistance Ranges |
400 ω 40 kω 4 Mω |
Resistance Accuracy |
400 ωand 40 kω ranges: ± (1.0 % rdg + 4 dgts) |
Resistance Accuracy |
4 Mω range: ± (1.2 % rdg + 4 dgts) |
Resistance Resolution |
100 mω |
Resistance Open Circuit Voltage |
400 ω range: 3.0 V dc, All other ranges: 0.5 V dc typical |
Frequency (autoranging) |
Ranges |
4 kHz, 40 kHz, 400 kHz, 4 MHz, 40 MHz |
Accuracy |
all ranges: ± (0.1 % rdg + 3 dgts) |
Resolution |
1 Hz |
Sensitivity |
10 Hz to 4 MHz: > 1.5 V ac rms
4 MHz to 40 MHz: > 2 V ac rms, < 5 V ac rms |
Min Pulse Width |
> 25 ns |
Duty Cycle Limits |
> 30 % and < 70 % |
Continuity |
Audible Indication |
< 35 ω |
Response Time |
100 ms |
Diode Test |
Test Current |
1.0 mA (approximate) |
Accuracy |
± (1.5 % rdg + 3 dgts) |
Resolution |
1 mV |
Open Circuit Volts |
3.0 V dc typical |
Peak Hold |
AC Volts Accuracy |
40 V to 750 V: ± (3.0 % rdg + 60 dgts) |
AC Current Accuracy |
± (3.0 % rdg + 60 dgts) |
Response Time |
> 1 ms |
Overload Protection |
AC/DC Voltage |
400 mV range: 1000 V dc or 750 V ac rms 15 sec
All other ranges: 1000 V dc or 750 V ac rms |
AC/DC Current |
uA/mA input: 0.315 A /1000 V fast-blow ceramic (6.3 x 32 mm)
10 A input: 10 A /1000 V fast-blow ceramic (10 x 38 mm)
(10 A for 4 minutes maximum followed by a 12 minute cooling period) |
Resistance |
1000 V dc or 750 V ac rms |
Continuity |
1000 V dc or 750 V ac rms |
Diode Test |
1000 V dc or 750 V ac rms |
Capacitance |
0.315 A /1000 V fast-blow ceramic (6.3 x 32 mm) |
Temperature |
1000 V dc or 750 V ac rms |
Frequency |
1000 V dc or 750 V ac rms |
|
|
Recently viewed products
-
|
|
T/C Source,Sngle.Type(J,K,T,E,R S,N,B,N,G,C,D,L,U,P,mV/0.1Res.)
|
|
|
|
$799.24
|
|
-
|
|