| Electrical Specifications |
| DC Voltage Ranges |
400 mV, 4 V, 40 V, 400 V, 1000 V |
| DC Voltage Accuracy |
all ranges: ± (0.7 % rdg + 1 dgt) |
| DC Voltage Resolution |
100 µV |
| DC Voltage Input Impedance |
10 Mω |
| AC Voltage (45 Hz to 500 Hz) Ranges |
400 mV, 4 V, 40 V, 400 V, 750 V |
| AC Voltage (45 Hz to 500 Hz) Accuracy |
4 V Range, 200 Hz to 500 Hz: ± (2.0 % rdg + 4 dgts) |
| AC Voltage (45 Hz to 500 Hz) Accuracy |
All other ranges: ± (1.5 % rdg + 4 dgts) |
| AC Voltage (45 Hz to 500 Hz) Resolution |
100 µV |
| AC Voltage (45 Hz to 500 Hz) Input Impedance |
10 Mω |
| DC Current Ranges |
400 µA, 4 mA, 40 mA, 300 mA, 10 A |
| DC Current Accuracy |
400 µA to 300 mA ranges: ± (1.0 % rdg + 1 dgt) |
| DC Current Accuracy |
10 A range: ± (2.0 % rdg + 3 dgts) |
| DC Current Resolution |
0.1 µA |
| DC Current Voltage Burden |
400 µA range: 1 mV/µA, 4 mA range: 100 mV/1 mA, 40 mA range: 12 mV/1 mA, |
| DC Current Voltage Burden |
300 mA range: 4 mV/1 mA, 10 A range: 100 mV/1 A |
| AC Current (45 Hz to 500 Hz) Ranges |
400 µA, 4 mA, 40 mA, 300 mA, 10 A |
| AC Current (45 Hz to 500 Hz) Accuracy |
400 µA to 300 mA ranges: ± (1.5 % rdg + 4 dgts) |
| AC Current (45 Hz to 500 Hz) Accuracy |
10 A range: ± (2.5 % rdg + 4 dgts) AC Current (45 Hz to 500 Hz) Resolution: 0.1 µA |
| AC Current (45 Hz to 500 Hz) Voltage Burden |
See DC Current |
| Resistance Ranges |
400 ω 40 kω 4 Mω |
| Resistance Accuracy |
400 ωand 40 kω ranges: ± (1.0 % rdg + 4 dgts) |
| Resistance Accuracy |
4 Mω range: ± (1.2 % rdg + 4 dgts) |
| Resistance Resolution |
100 mω |
| Resistance Open Circuit Voltage |
400 ω range: 3.0 V dc, All other ranges: 0.5 V dc typical |
| Frequency (autoranging) |
| Ranges |
4 kHz, 40 kHz, 400 kHz, 4 MHz, 40 MHz |
| Accuracy |
all ranges: ± (0.1 % rdg + 3 dgts) |
| Resolution |
1 Hz |
| Sensitivity |
10 Hz to 4 MHz: > 1.5 V ac rms
4 MHz to 40 MHz: > 2 V ac rms, < 5 V ac rms |
| Min Pulse Width |
> 25 ns |
| Duty Cycle Limits |
> 30 % and < 70 % |
| Continuity |
| Audible Indication |
< 35 ω |
| Response Time |
100 ms |
| Diode Test |
| Test Current |
1.0 mA (approximate) |
| Accuracy |
± (1.5 % rdg + 3 dgts) |
| Resolution |
1 mV |
| Open Circuit Volts |
3.0 V dc typical |
| Peak Hold |
| AC Volts Accuracy |
40 V to 750 V: ± (3.0 % rdg + 60 dgts) |
| AC Current Accuracy |
± (3.0 % rdg + 60 dgts) |
| Response Time |
> 1 ms |
| Overload Protection |
| AC/DC Voltage |
400 mV range: 1000 V dc or 750 V ac rms 15 sec
All other ranges: 1000 V dc or 750 V ac rms |
| AC/DC Current |
uA/mA input: 0.315 A /1000 V fast-blow ceramic (6.3 x 32 mm)
10 A input: 10 A /1000 V fast-blow ceramic (10 x 38 mm)
(10 A for 4 minutes maximum followed by a 12 minute cooling period) |
| Resistance |
1000 V dc or 750 V ac rms |
| Continuity |
1000 V dc or 750 V ac rms |
| Diode Test |
1000 V dc or 750 V ac rms |
| Capacitance |
0.315 A /1000 V fast-blow ceramic (6.3 x 32 mm) |
| Temperature |
1000 V dc or 750 V ac rms |
| Frequency |
1000 V dc or 750 V ac rms |