Operating Range |
Current Range |
0.5 to 200A |
Frequency Range |
40 to 10kHz |
Limit Operating Conditions |
200A permanently to 1kHz; Derating above 3kHz: 200A x (1/0.333 F), F in kHz |
Common Mode Voltage |
600VAC |
Crest Factor |
3 @ 200 Arms with an error (due to CF) of 4% |
Current Overload |
240A for 10 min |
Current Overload |
Range Value |
null |
Overload |
240A for 10 min ON, 30 min OFF |
Reference Conditions |
20° to 26°C, 20 to 75% RH, 48 to 65Hz, external magnetic field <40A/m, 48 to 65Hz sine wave, distortion factor less than 1%, no DC component, no external current carrying conductor, test sample centered. Load impedance 1MW |
Working Voltage |
600VAC |
Influence of Adjacent Conductor |
Range Value |
50Hz |
Influence of Adjacent Conductor |
< 15mA/A |
Influence of Conductor Position |
Influence of Conductor Position |
0.5% of Reading @ 50/60Hz |
Influence of Frequency |
Range Value |
40Hz to 1kHz / 1 to 10kHz |
Influence of Frequency |
3% of mV output / 12% of mV output |
Influence of Humidity |
Influence of Humidity |
10 - 90% RH: £0.2% of mV output per 10°K @ 18°C to 28°C |
Influence of Load |
Range Value |
40Hz to 1kHz / 1 to 10 kHz |
Influence of Load |
<3% of mA output / <12% of mA output |
Output Signal |
Output Signal |
1mV/A |
Mechanical Specifications |
Altitude |
Operating: 0 to 2000m; Non-operating: 0 to 12km |
Colors |
Dark gray handles with red cover |
Dimensions |
5.47 x 2.00 x 1.18" (139 x 51 x 30mm) |
Drop Test |
Test per IEC 68-2-32: 1.0 m drop on 38 mm of Oak on concrete |
Jaw Opening |
.84" (21mm) |
Material |
Jaws: Polycarbonate with 10% fiberglass charge, Red UL 94 V0; Case: Polycarbonate |
Maximum Bus Bar Size |
0.78 x 0.19" (20 x 5mm) |
Maximum Cable Diameter |
One 0.78" & Oslash; (20mm) |
Mechanical Shock |
100g per IEC 68-2-27 |
Operating Temperature |
14° to 131°F (-10° to 55°C) |
Operating Relative Humidity |
10° to 35°C 85% RH (without roll-off above 35°C) |
Output |
Double reinforced insulated 5 ft (1.5m) lead with safety 4mm banana plug |
Protection Index (IP) |
IP 40 (IEC 529) |
Impact Test |
IK04 0.5 J EN50102 |
Storage Temperature |
-40° to 158°F (-40° to 70°C) |
Vibration |
Test per IEC 68-2-6 |
Weight |
6.5 oz (180g) |
External Influences |
Influence of Temperature |
£150 ppm/°K, or 0.15% of mA output per 10K° |
Safety Reference Specifications |
Safety Ratings |
EN 61010-2-32 |
Agency Approvals |
CE Mark |