                        Product Highlights 
    Easily investigate sources of moisture build-up and      building envelope issues
Clearly see areas of concern with high-performance 160      x 120 thermal imaging sensor
Quickly find suspected problems with Infrared Guided      Measurement (IGM) technology
Easily identify both contexts and the issues with MSX      technology, which embosses visual details on full thermal images
Target exact sources of problems with integrated laser      pointer
Take comprehensive measurements and analyze moisture      readings
Quickly scan for moisture with integrated non-invasive      pinless sensor
Capture exact measurements with external pin probe      (included) and wide range of optional moisture probes (not included)
Reduce downtime with field-replaceable      temperature/humidity sensor
Calculated parameters based on multi-sensor input:      grains per pound or grams per kilogram, vapor pressure, and dew point
Create single file documenting comprehensive thermal      and visual imagery with hygrometer readings and laser location
Download images and data wirelessly or using included      USB cable
Analyze images and quickly generate reports with free      FLIR Tools software
Easy to use with intuitive interface Each Unit Includes 
    1 - FLIR MR2771 - FLIR MR13 Replaceable Temperature and Relative Humidity Sensor1 - FLIR MR02 Standard Moisture Pin Probe1 - Quick Start Guide1 - International USB Charger1 - USB Cable1 - Lanyard 
                          
    
        
            | General Specifications |  
            | OVERVIEW |  
            | Internal Memory | 8 GB |  
            | Laser Orientation | Single laser pointer to center of thermal image |  
            | Packaging Size | 55 × 31 × 32 (21.6 × 12.3 × 12.4 in) |  
            | Sensitivity | <70 mK |  
            | Typical Usage | 4 work weeks |  
            | Warranty | 10 year |  
            | COMPLIANCE & CERTIFICATIONS |  
            | Agency Approvals | CE, FCC Class B, RCM |  
            | ENVIRONMENTAL |  
            | Drop test | 3 m (9.8 ft) |  
            | Mixing Ratio | Range 0 to 560 GPP (0.0 to 80.0 g/kg) / Basic Accuracy ±2 GPP (0.25 g/kg) |  
            | Relative Humidity | Range 0 to 100% / Basic Accuracy 2.5% RH |  
            | Vapor Pressure | Range 0.0 to 12.0 kPa / Basic Accuracy ±0.05 kPa |  
            | IMAGING & OPTICAL |  
            | Continuous Run Time | 16 hours max |  
            | Digital Camera | 2 MP, 70.5° × 56° FOV |  
            | Display Type | QVGA (320 × 240 pixels) 2.8 in. color TFT graphical display |  
            | Image Modes | Thermal, Visual, MSX® |  
            | Image Update Speed Frequency | 9 Hz |  
            | Imaging Detector | FLIR Lepton microbolometer |  
            | Spectral Response | 8 to 14µm |  
            | Thermal image minimum focus distance | 10 cm (4 in) |  
            | Thermal image palettes | Iron, Rainbow, Arctic, White-Hot, Black-Hot |  
            | Field of View [W x H] | 55° × 43° |  
            | MSX | Embosses visual details on full resolution thermal image |  
            | Thermal Image Resolution [W x H] | 19200 pixels (160 × 120) |  
            | MEASUREMENT & ANALYSIS |  
            | Air Temperature | Range 32 to 122°F (0 to 50°C) / Basic Accuracy ±1.1°F (±0.6°C) |  
            | Dew Point | Range -30°C to 50°C (-22°F to 122°F) / Basic Accuracy ±1.0°C (±1.8°F) |  
            | Image Calibration | Automatic with manual lock scale option |  
            | Measurement Resolution | 0.1 |  
            | Pin Moisture | Range 7% to 30% / Basic Accuracy ±1.5% MC / Range 30% to 100% / Basic Accuracy Reference only |  
            | Pin Moisture Groups | 11 Material Groups |  
            | Pinless Measurement Depth | 19 mm (0.75 in) max |  
            | Pinless Moisture Range | 0 to 100 |  
            | Response Time Pin Mode | 750 ms |  
            | Response Time Pinless | 100 ms |  
            | METER DATA |  
            | Auto Power Off | Programmable: Off, 1, 5, or 20 minutes |  
            | OTHER |  
            | Certification Standards | EN 61326 (EMC), EN 60825-1 Class 2 (Laser) |  
            | POWER |  
            | Battery | Rechargeable 4.2 V, 5400 mAh LiPo |  
            | STORAGE MEDIA |  
            | Saved Image File format | Radiometric JPEG |  
            | Stored Image Capacity | 15000 images |    
    
        
            | Thermal Imagers/Building and Industrial Thermal Imagers Template |  
            |  | 160 x 120 Sensor |  
            |  | 70 mK (NETD) |  
            |  | 9 Hz |  
            |  | 55 x 43 Degrees |  
            | Screen Size | 2.3 IN |  
            |  | Yes |  
            | Video Output | No |  
            |  | Fixed |  
            |  | Yes |  
            |  | No |  
            | Video Recording | No |  
            | Touch Screen Display | No |  
            | Minimum Focus Distance | 10 CM (0.1 M) |  
            | Accuracy | 1.5 - 2.5% Depending on measurement type |  
            | Battery operating time Continuous | 18 HR |  
            |  | No |  
            |  | No |  
            |  | No |  
            | Environmental Testers / Physical Property/Moisture Meters Template |  
            | Measurement Methods (Moisture Meter) | Pin, Pinless |  
            | Materials Tested | Brick, Cardboard (Building Material), Concrete, Plaster, Sheet Rock, Wall Board, Wood |  
            | Measure Temperature | Yes |  
            | Measure Humidity | Yes |  
            | Dew Point | Yes |  
            |  | Yes |  
            | Self Calibration | No |  
            | Min/Max Memory | Yes |  
            | General Attributes |  
            | Product Height | 3.90 IN |  
            | Product Length | 11.10 IN |  
            | Product Width | 5.70 IN |  
            | Shipping Height | 3.90 IN |  
            | Shipping Length | 11.10 IN |  
            | Shipping Width | 5.70 IN |  
            | Country of Origin | China |  
         
            | Safety Approval | CE, UL |  
            | Interfaces I/O | USB |  
            | Storage | Internal Memory |  
            | HTS/Schedule B Number | 9027804560 |  |  
					
				 
					
                
        
        
              Probes
            
            
                
                        
                            | Product | Price |  
                            |  | FLIR MR02 
                                    Catalog #: MR02
Replacement Pin Probe for MR77 | $31.23
 
 |  
                            |  | FLIR MR06 
                                    Catalog #: MR06
Wall Cavity Probe for FLIR Moisture Meters | $220.23
 
 |  
                            |  | FLIR MR07 
                                    Catalog #: MR07
Hammer Probe for MRxx | $331.23
 
 |  
                            |  | FLIR MR08 
                                    Catalog #: MR08
Hammer and Wall Cavity Probe Combo for MRxx | $493.23
 
 |  
                            |  | FLIR MR09 
                                    Catalog #: MR09
Baseboard Probe for FLIR Moisture Meters | $226.23
 
 |  
              Accessories
            
            
                
                        
                            | Product | Price |  
                            |  | FLIR MR04 
                                    Catalog #: MR04
Extension Pole for MR77 and MR176 | $83.23
 
 |  
                            |  | FLIR MR05 
                                    Catalog #: MR05
Impact Pin Moisture Probe for MR77 | $83.23
 
 |  
				 |  
     |  |