| FLIR AX8 Specifications | 
        
            | Imaging and Optical Data | 
        
            | IR Resolution | 80x60 pixels | 
        
            | Thermal Sensitivity / NETD | <0.10°C @ +30°C (+86°F) / 100mK | 
        
            | Field of View (FOV) | 48° x 37° | 
        
            | Focus | Fixed | 
        
            | Detector Data | 
        
            | Detector Type | Focal Plane Array (FPA) Uncooled Microbolometer | 
        
            | Spectral Range | 7.3-13µm | 
        
            | Visual Camera | 
        
            | Built-in Digtal Camera | 640x480 | 
        
            | Digital Camera FOV | Adapts to the IR lens | 
        
            | Sensitivity | Minimum 10 Lux without illuminator | 
        
            | Measurement | 
        
            | Object Temperature Range | -10°C to +150°C (14°F to 302°F) | 
        
            | Accuracy | +/-2°C (+/-3.6°F) or +/-2% of reading (+10 to +100C@+10 to +35amb) | 
        
            | Measurement Analysis | 
        
            | Spotmeter | 6 | 
        
            | Area | 6 Boxes with max. / min. / average | 
        
            | Automatic Hot / Cold Detection | Max / Min temperature value and position shown within box | 
        
            | Measurement Presets | Yes | 
        
            | Atmospheric Transmission Correction | Automatic, based on inputs for distance, atmospheric temperature and relative humidity | 
        
            | Optics Transmission Correction | Automatic, based on signals from internal sensors | 
        
            | Emissivity Corrections | Variable from 0.01 to 1.0 | 
        
            | Reflected Apparent Temperature Correction | Automatic, based on input of reflected temperature | 
        
            | External Optics / Windows Correction | Automatic, based on input of optics / window transmission and temperature | 
        
            | Measurement Corrections | Global Object Parameters | 
        
            | Alarm | 
        
            | Alarm Functions | Automatic alarms on any selected measurement function. A maximum of 5 alarms can be set | 
        
            | Alarm Output | Digital Out, store image, file sending (ftp), email (smtp), notification | 
        
            | Set-Up | 
        
            | Color Palettes | Color palettes (BW, BW inv, Iron, Rain) | 
        
            | Set-up Commands | Data / Time, Temperature °C/°F | 
        
            | Web Interface | Yes | 
        
            | Storage of Images | 
        
            | Storage Media | Built-in memory for internal storage | 
        
            | Image Storage Mode | IR, Visual, MSX | 
        
            | File Formats | Jpeg + FFF | 
        
            | Ethernet | 
        
            | Ethernet | Control, result and image | 
        
            | Ethernet Type | 100 Mbps | 
        
            | Ethernet Standard | IEEE 802.3 | 
        
            | Ethernet Connector Type | M12 8-pin X-coded | 
        
            | Ethernet Video Streaming | Yes | 
        
            | Ethernet Power | Power over Ehternet, PoE IEEE 802.3as class 0 | 
        
            | Ethernet Protocols | Ehternet/IP, Modbus TCP, TCP, UDP, SNTP, RTSP, RTP, HTTP, ICMP, IGMP, SFTP, SMTP, SMB (CIFS), DHCP, MDNS (Bonjour) | 
        
            | Marine Electronics Interface | 
        
            | Multifunction Displays | Network compatible with Raymarine LightHouse II multifunction displays | 
        
            | Image Streaming | 
        
            | Image Streaming Formats | Motion JPEG, MPEG, H.264 | 
        
            | Image Streaming Resolution | 640x480 | 
        
            | Image Modes | Thermal, Visual, MSX (IR-image with enhanced detail presentation) | 
        
            | Automatic Image Adjustment | Continuous | 
        
            | Power Systems (POE Injector) | 
        
            | External Power Operations | 12/24VDC, 2W continuously / 3.1W absolute max | 
        
            | External Power Connector | Screw Connection (12V/0V/Chassis) | 
        
            | Voltage Allowed Range | 9-36VDC | 
        
            | Environment Data | 
        
            | Operating Temperature Range | 0°C to +50°C (32°F to +122°F) | 
        
            | Storage Temperature Range | –40°C to +70°C (–40°F to +158°F) IEC 68-2-1 and IEC 68-2-2 | 
        
            | Humidity (Operating and Storage) | IEC 60068-2-30/24 h 95% relative humidity +25°C to +40°C (+77°F to +104°F)/ 2 cycles | 
        
            | EMC | EN 61000-6-2:2001 (Immunity) | EN 61000-6-3:2001 (Emission) | FCC 47 CFR Part 15 Class B (Emission) | EN 60945:2002 | EN60945 (Electromagnetic Compliance) | 
        
            | Encapsulation | IP67 (IEC 60529) | 
        
            | Bump | 25 g (IEC 60068-2-29) | 
        
            | Vibration | 2 g (IEC 60068-2-6) EN 60945:2002
 | 
        
            | Ignition Protection | EN 28845:1993 | 
        
            | Physical Data | 
        
            | Camera size (L × W × H) | 54 × 25 × 79 mm (2.1 x 1 x 3.1 in.) w/o connectors 54 × 25 × 95 mm (2.1 x 1 x 3.7 in.) w/ connectors
 | 
        
            | Shipping Information | 
        
            | Packaging | Infrared camera with lens, printed documentation, user documentation CD-ROM, cooling/mounting plate, POE injector, Camera PoE Cable, Raymarine RayNet Ethernet cable |