Fluke Networks DSX2-8000QI
Catalog #: 4954622
Versiv 2 CableAnalyzer w/Quad OLTS and Fiber Inspection, Integrated Wi-Fi
- Overview
- Specifications
- Accessories
Product Highlights
- Kit includes the DSX2-8000 cable analyzer with integrated WiFi functionality, CertiFiber Pro Quad OLTS model, and USB video Inspection camera
- Capable of testing and certifying twisted pair Cat 5e, 6, 6A, 8 and Class I/II cabling with limits up to 2 GHz
- Has a level VI/2G accuracy (2 GHz)
- Versiv 2 enables users to accomplish more than ever with a cable tester, by accelerating every step of the testing process
- LinkWare Live cloud service lets the Project Manager remotely set up the testers, monitor job progress and even locate tester from any smart device
- ProjX management system eases tasks from initial set-up of a job to system acceptance. It eliminates redundant steps, and ensures that all tests are completed correctly the first time, and every time
- Taptive user interface puts advanced data analysis and easy set-up and operation at the fingertips of technicians of all skill levels
- LinkWare PC management software provides unmatched analysis of test results and professional test reports
- The DSX2-8000 reduces the time required to fix cabling faults with dedicated diagnostics, a simple test that locates the problem
Performance:
- Eight second Cat 6A test time contributes to the fastest way to gain certification
- Graphically displays the source of failures including crosstalk and distance to shield faults for faster troubleshooting
- Manage up to 12,000 Cat 6A test results with full graphics
- Capacitive touchscreen allows quick tester setup with easily selectable cable types, standards and testing parameters
- Over 1 billion links reported on LinkWare PC management software
Standards:
- Compliant with ANSI/TIA-1152-A Level 2G and proposed standard IEC 61935-1 Ed. 5 Level VI field tester accuracy requirements to 2000 MHz
- Supports the complete suite of Resistance Unbalance standards needed for Power over Ethernet (PoE) - IEEE 802.3bt, ANSI/TIA/EIA-568, ISO/IEC 11801 series documents
- TCL and ELTCTL measurements compliant to IEC 61935-1-1 (Draft)
- Screen continuity along path of cabling
Each Unit Includes
- 1 - Versiv 2 Mainframe and Remote Unit
- 2 - DSX-8000 CableAnalyzer Modules
- 2 - CertiFiber Quad OLTS Modules
- 1 - Set of Cat 8/Class I Permanent Link Adapters
- 1 - Set of Cat 8/Class I Channel Adapters
- 2 - Headsets
- 2 - Handstraps
- 2 - Shoulder Straps
- 1 - Carry Case
- 1 - USB Interface Cable
- 1 - Versiv 2 Open Source Software CD
- 2 - AC Chargers
- 2 - Universal Couplers
- 2 - AxTalk Terminators
- 1 - USB Video Inspection Probe w/ 4 Tips
- 2 - Quick Clean Cleaners (1.25/2.50 mm)
- 2 - LC/LC Simplex Adapters
- 1 - SC/LC EF-Compliant MM TRC Kit 50 µm
- 1 - SC/LC SM TRC Kit
- 1 - TRC Carry Case
- 1 - WiFi Adapter for Versiv 2 Mainframe
- 1 - Statement of Calibration
- 1 - Start Guide
Category 8 test modes (or lower link categories) |
ANSI/TIA-1152 Level 2G |
Class I/II test modes |
Proposed standard IEC 61935-1 Ed. 5 Level VI |
Length of Twisted Pair Cabling1 |
|
Without Remote |
With Remote |
Range |
800 m (2600 ft) |
150 m (490 ft) |
Resolution |
0.1 m or 1 ft |
0.1 m or 1 ft |
Accuracy |
± (0.3 m + 2 %); 0 m to 150 m
± (0.3 m + 4 %); 150 m to 800 m |
± (0.3 m + 2 %) |
Propagation Delay |
|
Without Remote |
With Remote |
Range |
4000 ns |
750 ns |
Resolution |
1 ns |
1 ns |
Accuracy |
± (2 ns + 2 %); 0 ns to 750 ns
± (2 ns + 4 %); 750 ns to 4000 ns |
± (2 ns + 2 %) |
Delay Skew |
Range |
0 ns to 100 ns |
Resolution |
1 ns |
Accuracy |
± 10 ns |
DC Loop Resistance Test |
Range |
0 Ω to 540 Ω |
Resolution |
0.1 Ω |
Accuracy |
± (1 Ω + 1 %) |
Overload recovery time |
Less than 10 minutes to rated accuracy following an overvoltage. Referencing is required after repeated or prolonged overvoltage. |
Fluke Networks CertiFiber Pro Optical Loss Test Set Specifications |
Power Meter Specifications |
Input Connector |
Interchangeable connector adapter (LC standard, SC, ST and FC optional) |
Detector Type |
InGaAs |
Wavelengths |
850 nm, 1300 nm, 1310 nm, 1550 nm |
Power Measurement Range |
0 dBm to -65 dBm (850 nm) 0 dBm to -70 dBm (all other wavelengths) |
Power Measurement Uncertainty1,2 |
< +/- 5% +/- 32 pW |
Measurement Linearity3 |
< ± 0.1 dB |
Re-calibration Period |
1 year |
1. +/- 100 pW at 850 nm
2. Under the following conditions: Power level 100 μW (-10 dBm), continuous wave (CW) for absolute power at 850 nm and 1310 nm. Divergent beam, NA = 0.20 for 50/125 μm and NA = 0.14 for 9/125 μm. Ambient temperature 23° ± 1°C. SC/UPC connector with ceramic ferrule. After a 5 minute warm-up. Traceable to NIST.
3. -3 dBm to -55 dBm at 850 nm and 1310 nm. Ambient temperature 23° ± 1°C. After a 5 minute warm-up. |
Loss/Length Specifications |
Specification |
CertiFiber Pro Multimode Modules |
CertiFiber Pro Singlemode Modules |
Testing Speeds (excludes referencing times) |
Smart Remote mode: < 3 seconds (2 wavelengths, one direction, auto wavelength detection)
Far End Source mode: ≤ 2 seconds (2 wavelengths, one direction auto wavelength detection)
Loopback mode: ≤ 2 seconds (2 wavelengths, one direction auto wavelength detection) |
Input/Output Connectors |
Interchangeable connector adapter (LC standard, SC, ST and FC optional) |
Launch Condition1,2 |
Encircled Flux compliant to TIA-526-14-B, ISO/IEC 14763-3 and IEC 61280-4-1 |
Fiber Types Tested |
50/125 µm or 62.5/125 µm |
singlemode |
Source Type and Wavelengths |
LED source 850 nm ± 30 nm 1300 nm ± 20 nm |
Fabry-Perot laser diode 1310 nm ± 20 nm 1550 nm ± 30 nm |
Maximum Length Measurement |
12 km |
130 km |
Length Measurement Accuracy |
± 1.5 m plus ± 1 % of length |
± 1.5 m plus ± 1 % of length |
Output Power (Nominal) |
≥ -24 dBm with EF-TRC |
≥ -4 dBm |
Output Power Stability3 |
± 0.05 dB over 8 hours ± 0.03 dB over 15 minutes |
± 0.1 dB over 8 hours ± 0.08 dB over 15 minutes |
1. At the output of the EF-TRC
2. Variations between EF measurement equipment may occur but EF compliance can be expected with a 95% confidence factor
3. Relative to power level after 15 minute warm up – at constant temperature |
Loss/Length Specifications (continued) |
Source Wavelengths |
850 nm, 1300 nm, 1310 nm, 1550 nm |
Power Measurement Range |
0 dBm to -65 dBm (850 nm) 0 dBm to -70 dBm (all other wavelengths) |
Power Measurement Uncertainty1, 2 |
< +/- 5% +/- 32 pW |
Measurement Linearity3 |
< ± 0.1 dB |
Re-calibration Period |
1 year |
1. +/- 100 pW at 850 nm
2. Under the following conditions: Power level 100 μW (-10 dBm), continuous wave (CW) for absolute power at 850 |
Selected Specifications |
Visual Fault Locator (VFL) |
Title |
Requirement |
Output Power |
>-5 dBm
<0 dBm
SMF-28 singlemode fiber
Continuous wave
SC/UPC connector |
Operating Wavelength |
650 nm nominal |
Output Modes |
Continuous wave
Pulsed mode (2 Hz to 3 Hz blink frequency) |
Connector Adapter |
2.5 mm universal |
Laser Safety |
Class II CDRH
Over operating temperature range |
Environmental Specifications |
Title |
Requirement |
Operating Temperature |
-18° C to 45° C |
Storage Temperature |
-30° C to +60° C |
Operating Relative Humidity
% RH without condensation |
0 % to 90 %, 32 °F to 95 °F (0° C to 35° C)
0 % to 70 %, 95 °F to 113 °F (35° C to 45° C) |
Vibration |
Random, 2 g, 5 Hz-500 Hz |
Shock |
1 m drop test with and without module and adapters |
Safety |
CSA C22.2 No. 1010.1: 1992
EN 61010-1 1st Edition + Amendments 1, 2 |
Pollution Degree |
2 |
Altitude |
Operating: 4,000 m; storage: 12,000 m |
EMC |
EN 61326–1 |
|
|
|
|