|
Fluke Networks DSX2-8000-PRO
Catalog #: 4954813
Versiv 2 CableAnalyzer Professional Kit with Integrated Wi-Fi
- Overview
- Specifications
- Accessories
Product Highlights
- The Professional Kit includes the DSX-8000 CableAnalyzer, Quad OLTS and Quad OTDR Fiber Inspection with integrated WiFi functionality
- Capable of testing and certifying twisted pair Cat 5e, 6, 6A, 8 and Class I/II cabling with limits up to 2 GHz
- Has a level VI/2G accuracy (2 GHz)
- Versiv 2 enables users to accomplish more than ever with a cable tester, by accelerating every step of the testing process
- LinkWare Live cloud service lets the Project Manager remotely set up the testers, monitor job progress and even locate tester from any smart device
- ProjX management system eases tasks from initial set-up of a job to system acceptance. It eliminates redundant steps, and ensures that all tests are completed correctly the first time, and every time
- Taptive user interface puts advanced data analysis and easy set-up and operation at the fingertips of technicians of all skill levels
- LinkWare PC management software provides unmatched analysis of test results and professional test reports
- The DSX reduces the time required to fix cabling faults with dedicated diagnostics, a simple test that locates the problem
Performance:
- Eight second Cat 6A test time contributes to the fastest way to gain certification
- Graphically displays the source of failures including crosstalk and distance to shield faults for faster troubleshooting
- Manage up to 12,000 Cat 6A test results with full graphics
- Capacitive touchscreen allows quick tester setup with easily selectable cable types, standards and testing parameters
- Over 1 billion links reported on LinkWare PC management software
Standards:
- Compliant with ANSI/TIA-1152-A Level 2G and proposed standard IEC 61935-1 Ed. 5 Level VI field tester accuracy requirements to 2000 MHz
- Supports the complete suite of Resistance Unbalance standards needed for Power over Ethernet (PoE) - IEEE 802.3bt, ANSI/TIA/EIA-568, ISO/IEC 11801 series documents
- TCL and ELTCTL measurements compliant to IEC 61935-1-1 (Draft)
- Screen continuity along path of cabling
Each Unit Includes
- 2 - Versiv Mainframes
- 2 - Headsets
- 2 - Hand Straps
- 2 - Shoulder Straps
- 1 - Hard sided Carry Case
- 2 - Large Duffle Bags
- 1 - Backpack straps for Versiv Duffle Bag
- 2 - Versiv stands
- 1 - USB Interface Cable
- 1 - Versiv Open Source Software CD
- 2 - AC Chargers
- 2 - Universal Couplers
- 1 - Statement of Calibration
- 1 - Getting Started Guide
- 2 - DSX-8000 CableAnalyzer Modules
- 2 - AxTalk Terminators
- 1 - Set of Cat 8/Class I Permanent Link Adaptors
- 1 - Set of Cat 8/Class I Channel Adaptors
- 1 - Universal Permanent Link Adaptors Set (accepts personality modules)
- 1 - DSX Series Coaxial Adapter Set
- 1 - DSX Patch Cord Test Adapter Set for Category 5e patch cords
- 1 - DSX Patch Cord Test Adapter Set for Category 6 patch cords
- 1 - DSX Patch Cord Test Adapter Set for Category 6A patch cords
- 1 - DSX M12 4-position Channel Adapter Set
- 2 - CertiFiber Pro Quad OLTS Modules
- 4 - Sets of 50 µm Multimode EF TRC kits: SC/LC (2 SC/LC, 2 LC/LC) , SC/SC (4 SC/SC), SC/ST (2 SC/ST, 2 ST/ST), SC/FC (2 SC/FC, 2 FC/FC)
- 4 - Sets of 62.5 µm Multimode EF TRC kits: SC/LC (2 SC/LC, 2 LC/LC) , SC/SC (4 SC/SC), SC/ST (2 SC/ST, 2 ST/ST), SC/FC (2 SC/FC, 2 FC/FC)
- 4 - Sets of 9 µm Singlemode TRC kits: SC/LC (2 SC/LC, 2 LC/LC) , SC/SC (4 SC/SC), SC/ST (2 SC/ST, 2 ST/ST), SC/FC (2 SC/FC, 2 FC/FC)
- 4 - TRC Carry Cases
- 4 - Sets of Interchange Adapters (LC – installed on units, SC, ST and FC)
- 1 - OptiFiber Pro Quad OTDR Module
- 1 - Set of 50 µm Multimode Launch Cords (3 SC/LC, 3 SC/SC, 2 SC/ST, 2 SC/FC, 1 LC/LC, 1 ST/ST, 1 FC/FC)
- 1 - Set of 62.5 µm Multimode Launch Cords (1 SC/LC, 3 SC/SC, 2 SC/ST, 2 SC/FC)
- 1 - Set of 9 µm Singlemode Launch Cords (3 SC/LC, 3 SC/SC, 2 SC/ST, 2 SC/FC, 1 LC/LC, 1 ST/ST, 1 FC/FC, 2 SC/SCAPC, 2 SC/LCAPC)
- 1 - Set of 50 µm Multimode TRC OTDR port savers (SC/SC, LC/LC)
- 1 - Set of 62.5 µm Multimode TRC OTDR port savers (SC/SC, LC/LC)
- 1 - Set of 9 µm Singlemode TRC OTDR port savers (SC/SC, LC/LC)
- 1 - OTDR Source Port Interchange Adapter Sets (LC – installed on unit, SC/ST, FC)
- 2 - OTDR Hanging straps and magnets
- 2 - Versiv USB inspection cameras and tips sets
- 2 - Quick Clean Cleaners (1.25 mm)
- 2 - Quick Clean Cleaners (2.50 mm)
- 1 - Enhanced Fiber Optic Cleaning Kit with Quick Clean cleaners
Category 8 test modes (or lower link categories) |
ANSI/TIA-1152 Level 2G |
Class I/II test modes |
Proposed standard IEC 61935-1 Ed. 5 Level VI |
Length of Twisted Pair Cabling1 |
|
Without Remote |
With Remote |
Range |
800 m (2600 ft) |
150 m (490 ft) |
Resolution |
0.1 m or 1 ft |
0.1 m or 1 ft |
Accuracy |
± (0.3 m + 2 %); 0 m to 150 m
± (0.3 m + 4 %); 150 m to 800 m |
± (0.3 m + 2 %) |
Propagation Delay |
|
Without Remote |
With Remote |
Range |
4000 ns |
750 ns |
Resolution |
1 ns |
1 ns |
Accuracy |
± (2 ns + 2 %); 0 ns to 750 ns
± (2 ns + 4 %); 750 ns to 4000 ns |
± (2 ns + 2 %) |
Delay Skew |
Range |
0 ns to 100 ns |
Resolution |
1 ns |
Accuracy |
± 10 ns |
DC Loop Resistance Test |
Range |
0 Ω to 540 Ω |
Resolution |
0.1 Ω |
Accuracy |
± (1 Ω + 1 %) |
Overload recovery time |
Less than 10 minutes to rated accuracy following an overvoltage. Referencing is required after repeated or prolonged overvoltage. |
Fluke Networks CertiFiber Pro Optical Loss Test Set Specifications |
Power Meter Specifications |
Input Connector |
Interchangeable connector adapter (LC standard, SC, ST and FC optional) |
Detector Type |
InGaAs |
Wavelengths |
850 nm, 1300 nm, 1310 nm, 1550 nm |
Power Measurement Range |
0 dBm to -65 dBm (850 nm) 0 dBm to -70 dBm (all other wavelengths) |
Power Measurement Uncertainty1,2 |
< +/- 5% +/- 32 pW |
Measurement Linearity3 |
< ± 0.1 dB |
Re-calibration Period |
1 year |
1. +/- 100 pW at 850 nm
2. Under the following conditions: Power level 100 μW (-10 dBm), continuous wave (CW) for absolute power at 850 nm and 1310 nm. Divergent beam, NA = 0.20 for 50/125 μm and NA = 0.14 for 9/125 μm. Ambient temperature 23° ± 1°C. SC/UPC connector with ceramic ferrule. After a 5 minute warm-up. Traceable to NIST.
3. -3 dBm to -55 dBm at 850 nm and 1310 nm. Ambient temperature 23° ± 1°C. After a 5 minute warm-up. |
Loss/Length Specifications |
Specification |
CertiFiber Pro Multimode Modules |
CertiFiber Pro Singlemode Modules |
Testing Speeds (excludes referencing times) |
Smart Remote mode: < 3 seconds (2 wavelengths, one direction, auto wavelength detection)
Far End Source mode: ≤ 2 seconds (2 wavelengths, one direction auto wavelength detection)
Loopback mode: ≤ 2 seconds (2 wavelengths, one direction auto wavelength detection) |
Input/Output Connectors |
Interchangeable connector adapter (LC standard, SC, ST and FC optional) |
Launch Condition1,2 |
Encircled Flux compliant to TIA-526-14-B, ISO/IEC 14763-3 and IEC 61280-4-1 |
Fiber Types Tested |
50/125 µm or 62.5/125 µm |
singlemode |
Source Type and Wavelengths |
LED source 850 nm ± 30 nm 1300 nm ± 20 nm |
Fabry-Perot laser diode 1310 nm ± 20 nm 1550 nm ± 30 nm |
Maximum Length Measurement |
12 km |
130 km |
Length Measurement Accuracy |
± 1.5 m plus ± 1 % of length |
± 1.5 m plus ± 1 % of length |
Output Power (Nominal) |
≥ -24 dBm with EF-TRC |
≥ -4 dBm |
Output Power Stability3 |
± 0.05 dB over 8 hours ± 0.03 dB over 15 minutes |
± 0.1 dB over 8 hours ± 0.08 dB over 15 minutes |
1. At the output of the EF-TRC
2. Variations between EF measurement equipment may occur but EF compliance can be expected with a 95% confidence factor
3. Relative to power level after 15 minute warm up – at constant temperature |
Loss/Length Specifications (continued) |
Source Wavelengths |
850 nm, 1300 nm, 1310 nm, 1550 nm |
Power Measurement Range |
0 dBm to -65 dBm (850 nm) 0 dBm to -70 dBm (all other wavelengths) |
Power Measurement Uncertainty1, 2 |
< +/- 5% +/- 32 pW |
Measurement Linearity3 |
< ± 0.1 dB |
Re-calibration Period |
1 year |
1. +/- 100 pW at 850 nm
2. Under the following conditions: Power level 100 μW (-10 dBm), continuous wave (CW) for absolute power at 850 |
Selected Specifications |
Visual Fault Locator (VFL) |
Title |
Requirement |
Output Power |
>-5 dBm
<0 dBm
SMF-28 singlemode fiber
Continuous wave
SC/UPC connector |
Operating Wavelength |
650 nm nominal |
Output Modes |
Continuous wave
Pulsed mode (2 Hz to 3 Hz blink frequency) |
Connector Adapter |
2.5 mm universal |
Laser Safety |
Class II CDRH
Over operating temperature range |
Environmental Specifications |
Title |
Requirement |
Operating Temperature |
-18° C to 45° C |
Storage Temperature |
-30° C to +60° C |
Operating Relative Humidity
% RH without condensation |
0 % to 90 %, 32 °F to 95 °F (0° C to 35° C)
0 % to 70 %, 95 °F to 113 °F (35° C to 45° C) |
Vibration |
Random, 2 g, 5 Hz-500 Hz |
Shock |
1 m drop test with and without module and adapters |
Safety |
CSA C22.2 No. 1010.1: 1992
EN 61010-1 1st Edition + Amendments 1, 2 |
Pollution Degree |
2 |
Altitude |
Operating: 4,000 m; storage: 12,000 m |
EMC |
EN 61326–1 |
Key OTDR specifications |
|
Multimode module |
Singlemode module |
Quad module |
Wavelengths |
850 nm +/- 10 nm
1300 nm +35/-15 nm |
1310 nm +/- 25 nm
1550 nm +/- 30 nm |
850 nm +/- 10 nm
1300 nm +35/-15 nm
1310 nm +/- 25 nm
1550 nm +/- 30 nm |
Compatible fiber types |
50/125 µm
62.5/125 µm |
Singlemode |
50/125 µm
62.5/125 µm
Singlemode |
Event dead zone 1 |
850 nm: 0.5 m typical
1300 nm: 0.7 m typical |
1310 nm: 0.6 m typical
1550 nm: 0.6 m typical |
850 nm: 0.5 m typical
1300 nm: 0.7 m typical
1310 nm: 0.6 m typical
1550 nm: 0.6 m typical |
Attenuation dead zone 2 |
850 nm: 2.5 m typical
1300 nm: 4.5 m typical |
1310 nm: 3.6 m typical
1550 nm: 3.7 m typical |
850 nm: 2.5 m typical
1300 nm: 4.5 m typical
1310 nm: 3.6 m typical
1550 nm: 3.7 m typical |
Dynamic range 3, 5, 6 |
850 nm: 28 dB typical
1300 nm: 30 dB typical |
1310 nm: 32 dB typical
1550 nm: 30 dB typical |
850 nm: 28 dB typical
1300 nm: 30 dB typical
1310 nm: 32 dB typical
1550 nm: 30 dB typical |
Max distance range setting |
40 km |
130 km |
MM: 40 km
SM: 130 km |
Distance measurement range 4, 5, 7, 8, 9, 10 |
850 nm: 9 km
1300 nm: 35 km |
1310 nm: 80 km
1550 nm: 130 km |
850 nm: 9 km
1300 nm: 35 km
1310 nm: 80 km
1550 nm: 130 km |
Reflectance range 4, 5 |
850 nm: -14 dB to -57 dB (typical)
1300 nm: -14 dB to -62 dB (typical) |
1310 nm: -14 dB to -65 dB (typical)
1550 nm: -14 dB to -65 dB (typical) |
850 nm: -14 dB to -57 dB (typical)
1300 nm: -14 dB to -62 dB (typical)
1310 nm: -14 dB to -65dB (typical)
1550 nm: -14 dB to -65 dB (typical) |
Sample resolution |
3 cm to 400 cm |
3 cm to 400 cm |
3 cm to 400 cm |
Pulse widths (nominal) |
850 nm: 3, 5, 20, 40, 200 ns
1300 nm: 3, 5, 20, 40, 200, 1000 ns |
1310/1550 nm: 3, 10, 30, 100, 300, 1000, 3000, 10000, 20000 ns |
850 nm: 3, 5, 20, 40, 200 ns
1300 nm: 3, 5, 20, 40, 200, 1000 ns
1310/1550 nm: 3, 10, 30, 100, 300, 1000, 3000, 10000, 20000 ns |
Test time (per wavelength) |
Auto setting: 5 sec (typical) |
Auto setting: 10 sec (typical) |
Auto setting:
MM - 5 sec (typical)
SM - 10 sec (typical) |
Quick test setting:
2 sec (typical) |
Quick test setting:
5 sec (typical) |
Quick test setting:
MM - 2 sec (typical)
SM - 5 sec (typical) |
Best resolution setting:
2 to 180 sec |
Best resolution setting:
5 to 180 sec |
Best resolution setting:
MM - 2 to 180 sec M
SM - 5 to 180 sec |
FaultMap setting:
2 sec (typical), 180 sec (max) |
FaultMap setting:
10 sec (typical), 180 sec (max) |
FaultMap setting:
MM - 2 sec (typical), MM - 180 sec (max)
SM - 10 sec (typical), SM - 180 sec (max) |
DataCenter OTDR setting:
1 sec (typical at 850 nm), 7 sec (max) |
DataCenter OTDR setting:
20 sec (typical), 40 sec (max) |
DataCenter OTDR setting:
MM - 1 sec (typical at 850 nm) MM - 7 sec (max)
SM - 20 sec (typical) SM - 40 sec (max) |
Manual setting:
3, 5, 10, 20, 40, 60, 90, 120, 180 sec |
Manual setting:
3, 5, 10, 20, 40, 60, 90, 120, 180 sec |
Manual setting:
-3, 5, 10, 20, 40, 60, 90, 120, 180 sec SM - 3, 5, 10, 20, 40, 60, 90, 120, 180 sec |
- Measured at 1.5 dB below non-saturating reflection peak with the shortest pulse width. Reflection peak < -40 dB for multimode and < - 50 dB for singlemode.
- Measured at +/- 0.5 dB deviation from backscatter with the shortest pulse width. Reflection peak < -40 dB for multimode and < - 50 dB for singlemode.
- For typical backscatter coefficient for OM1 fiber: 850: -65 dB, 1300: -72 dB.
- Typical backscatter and attenuation coefficients for OM2-OM4 fiber: 850 nm: -68 dB; 2.3 dB/km: 1300 nm: -76 dB; 0.6 dB/km.
- Typical backscatter and attenuation coefficients for OS1-OS2 fiber: 1310nm : -79 dB; 0.32 dB/km; 1550 nm: -82 dB; 0.19 dB/km.
- SNR = 1 method, 3 minute averaging, widest pulse width.
- 850 = 9 km typical to find the end or 7 km typical to find a 0.1 dB event (with a maximum of 18 dB attenuation prior to the event).
- 1300 = 35 km typical to find the end or 30 km typical to find a 0.1 dB event (with a maximum of 18 dB attenuation prior to the event).
- 1310 = 80 km typical to find the end or 60km typical to find a 0.1 dB event (with a maximum of 20 dB attenuation prior to the event).
- 1550 = 130 km typical to find the end or 90 km typical to find a 0.1 dB event (with a maximum of 18 dB attenuation prior to the event).
- Does not include index of refraction error and does not include automatic event location error.
- dB variation per 1 dB step.
- Applies along the trace backscatter within the distance range in which the OTDR can find a 0.1 dB event.
|
|
|