Fluke I430-FLX-TFII-12
Catalog #: 4621205
6000 A Flexible AC Current Probe 30cm (12 inch)
- Overview
- Specifications
- Summary
Product Highlights
- 6000 A Flexible AC Current Probe 30cm (12 inch)
- For use with the Fluke 430 series I and II Power Quality Analyzers and other dedicated test tools.
- Optimized for current measurement on thick and hard to reach conductors.
General Specifications |
|
i430-Flexi- |
|
TF-II |
TF-II-48 |
Transducer length |
61 cm (24 in) |
122 cm (48 in) |
Weight |
153 g |
200 g |
Transducer diameter |
7.5 mm (0.3 in) |
Minimum bending radius |
38 mm (1.5 in) |
Cable length from transducer to BNC |
2.5 m (98.4 in) |
Temperature, operating |
-20 °C to +70 °C (-4 °F to +158 °F)
Temperature of conductor under test shall not exceed 80 °C (176 °F) |
Temperature, non-operating |
-40°C to + 80 °C (-40 °F to +176 °F) |
Relative Humidity, operating |
15 % to 85 %, noncondensing |
Altitude, operating |
2 000 m (6 500 ft); for use up to 4000 moderate to 300 V CAT IV, 600 V CAT III, 1000 V CAT II. |
Altitude, storage |
12 km (40 000 ft) |
Ingress protection |
IP40 |
Specifications |
SAFETY W |
The i430-Flexi-TF-II complies with:
• IEC 61010-1: Pollution degree 2
• IEC 61010-2-032: CAT IV 600 V / CAT III 1000 V |
Electrical Specifications |
Measuring range |
0.5 A ac to 6000 A ac |
Maximum non-destructive current |
100 kA (50/60 Hz) |
Output signal |
86.6 mV at 1000 A/50 Hz (on 1 MΩ)
85.0 mV at 1000 A/50 Hz (on 50 kΩ) |
Basic accuracy |
±1 % of reading at 25 °C, 50 Hz with conductor placed at the center of the probe |
Linearity |
±0.2 % of reading at 10 % to 100 % of range |
Noise |
<1 mV rms at 10 Hz to 10 kHz |
Additional errors
- temperature coefficient over operating temperature range
-for 24 inch model
-for 48 inch model
- with position of conductor in the probe window (see Figure 1):
Zone A
Zone B
Zone C
- 0.5 to 30 A
|
0.02 % of reading / °C (0.011 % / °F)
0.035 % of reading / °C (0.02 % / °F)
±0.5 % of reading
±1.0 % of reading
±2.0 % of reading
±1 count or 0.1 A (whichever is greater) |
External magnetic field rejection in reference to external current |
40 dB (with cable >100 mm from the head coupling and r-coil) |
Phase shift (fundamental frequency) |
<±1° |
Bandwidth (-3 dB) |
10 Hz to 10 kHz |
Frequency derating |
I x f ≤385 kA Hz |
Country of Origin |
Bulgaria |
|
|
|
|