Fluke 810/+TRNG
Catalog #: 4878251
Fluke 810 Vibration Tester plus Training Program Book
- Overview
- Specifications
- Summary
- Cases
- Accessories
Product Highlights
- On-board identification and location of the most common mechanical faults (bearings, misalignment, unbalance, looseness) focus maintenance efforts on root cause, reducing unplanned downtime
- Fault severity scale with four severity levels helps you prioritize maintenance work
- Repair recommendations advise technicians on corrective action
- On-board context sensitive help provides real-time tips and guidance to new users
- 2 GB expandable on-board memory provides enough space for your machinery’s data
- Self-test function ensures optimal performance and more time on the job
- Laser tachometer for accurate machine running speed promotes confident diagnoses
- Tri-axial accelerometer reduces measurement time by 2/3 over single axis accelerometers
- Viewer PC Software expands data storage and tracking capacity
- Includes Training program book
Each Unit Includes
- Vibration Tester with diagnostic technology
- Tri-axial accelerometer, magnet mount, mounting pad kit with adhesive, accelerometer quick-disconnect cable
- Laser tachometer and storage pouch
- Smart battery pack with cable and adapters
- Shoulder strap and adjustable hand strap
- Viewer PC software
- Mini USB to USB cable
- Getting Started Guide, illustrated quick reference guide, Users Manual CD-ROM,
- Carrying case
- Training Program Book
Diagnostic specifications |
Standard faults |
Unbalance, looseness, misalignment and bearing failures |
Analysis for |
Motors, fans, blowers, belts and chain drives, gearboxes, couplings, centrifugal pumps, piston pumps, sliding vane pumps, propeller pumps, screw pumps, rotary thread/gear/lobe pumps, piston compressors, centrifugal compressors, screw compressors, closed coupled machines, spindles |
Machine rotational speed range |
200 rpm to 12000 rpm |
Diagnosis details |
Plain-text diagnosis, fault severity (slight, moderate, serious, extreme), repair details, cited peaks, spectra |
Electrical specifications |
Ranging |
Automatic |
A/D converter |
4 channel, 24 bit |
Usable bandwidth |
2 Hz to 20 kHz |
Sampling |
51.2 Hz |
Digital signal processing functions |
Automatically configured anti-alias filter, high-pass filter, decimation, overlapping, windowing, FFT, and averaging |
Sampling rate |
2.5 kHz to 50 kHz |
Dynamic range |
128 dB |
Signal to noise ratio |
100 dB |
FFT resolution |
800 lines |
Spectral windows |
Hanning |
Frequency units |
Hz, orders, cpm |
Amplitude units |
in/sec, mm/sec, VdB (US), VdB* (Europe) |
Non-volatile memory |
SD micro memory card, 2 GB internal + user accessible slot for additional storage |
General specifications |
Dimensions (HxDxW) |
18.56 cm x 7.00 cm x 26.72 cm (7.30 in x 2.76 in x 10.52 in) |
Weight (with battery) |
1.9 kg (4.2 lb) |
Display |
¼ VGA, 320 × 240 Color (5.7 inch diagonal) TFT LCD with LED backlight |
Input/Output Connections |
Triaxial sensor connection 4 pin M12 connector
Single axis sensor connection BNC connector
Tachometer Connection Mini DIN 6 pin connector
PC Connection Mini ‘B’ USB (2.0) connector |
Battery |
Battery type Lithium-ion, 14.8 V, 2.55 Ah
Battery charging time Three hours
Battery discharge time Eight hours (under normal conditions) |
AC adapter |
Input voltage 100 Vac to 240 Vac
Input frequency 50/60 Hz |
Operating system |
WinCE 6.0 Core |
Language Support |
English, French, German, Italian, Japanese, Portuguese, Simplified Chinese, Spanish |
Warranty |
Three-years |
Environmental Specifications |
Operating temperature |
0 °C to 50 °C (32 °F to 122 °F) |
Storage temperature |
-20 °C to 60 °C (-4 °F to 140 °F) |
Operating humidity |
10 % to 95 % RH (non-condensing) |
Agency approvals |
CHINA RoHS, CSA, CE, C TICK, WEEE |
Electromagnetic compatibility |
EN 61326-1:2006, EN 61010:1:2001 2nd ed. |
Sensor specifications |
Sensor type |
Accelerometer |
Sensitivity |
100 mV/g (± 5 %, 25 °C) |
Acceleration range |
80 g peak |
Amplitude nonlinearity |
1 % |
Frequency response |
Z: 2 - 7,000 Hz ± 3dB
X, Y: 2 - 5,000 Hz ± 3dB |
Power requirement (IEPE) |
18 V dc to 30 V dc, 2 mA to 10 mA |
Bias output voltage |
12 V dc |
Grounding |
Case grounded |
Sensing element design |
PZT ceramic / shear |
Case material |
316L stainless steel |
Mounting |
10-32 captive socket head screw, 2-pole rare earth magnet (48 lb pull strength) |
Output connector |
4-Pin, M12 |
Mating connector |
M12 - F4D |
Non-volatile memory |
TEDS 1451.4 compatible |
Vibration limit |
500 g peak |
Shock limit |
5000 g peak |
Electromagnetic sensitivity, equivalent g |
100 µg/gauss |
Sealing |
Hermetic |
Temperature range |
-50 °C to 120 °C (-58 °F to 248 °F) ± 7 % |
Warranty |
One-year |
Tachometer specifications |
Dimensions (DxW) |
2.86 cm x 12.19 cm (1.125 in x 4.80 in) |
Weight |
96 g (3.4 oz) with cable |
Power |
Powered by 810 Vibration Tester |
Detection |
Laser Diode Class 2 |
Range |
6.0 to 99,999 rpm |
Accuracy |
6.0 to 5999.9 rpm: ± 0.01 % and ± 1 digit
5999.9 to 99999 rpm: ± 0.05 % and ± 1 digit |
Resolution |
0.1 rpm |
Effective range |
1 cm to 100 cm (0.4 in to 39.27 in) |
Response time |
1 second (> 60 rpm) |
Controls |
Measure on/off transparent button |
Interface |
6 Pin Mini DIN |
Cable length |
50 cm (19.586 in) |
Warranty |
3 Years |
Tachometer accessories |
Reflective tape: 1.5 cm x 52.5 cm (0.59 in × 20.67 in) |
Viewer PC Software |
Minimum hardware requirements |
1 GB RAM |
Operating system requirements |
Windows XP, Vista |
Reliability / Preventative Maint / Rotational/Vibration Meter Template |
Velocity Range |
12000 RPM |
Frequency Range |
20 kHz (20000 Hz) |
Single Axis Measurement |
Yes |
Tri-Axial Measurement |
Yes |
Tachometer Capability |
Yes |
Peak/Hold |
No |
Data Logging |
No |
Unique Features |
On-board identification and location of the most common mechanical faults (bearings, misalignment, unbalance, looseness) focus maintenance efforts on root cause, reducing unplanned downtime.
Fault severity scale with four severity levels helps you prioritize maintenance work.
Repair recommendations advise technicians on corrective action.
On-board context sensitive help provides real-time tips and guidance to new users.
2 GB expandable on-board memory provides enough space for your machinery’s data.
Self-test function ensures optimal performance and more time on the job.
Laser tachometer for accurate machine running speed promotes confident diagnoses.
Tri-axial accelerometer reduces measurement time by 2/3 over single axis accelerometers.
Viewer PC Software expands data storage and tracking capacity. |
Warranty |
1 YEARS |
Calibration Included |
None |
Power Supply Voltage |
120V/220V Universal |
Interfaces I/O |
Other, USB |
Storage |
Micro SD |
Product Weight |
15.79 LBS |
Battery Type |
Li-ion |
Product Height |
6.69 IN |
Product Length |
14.57 IN |
Product Width |
18.75 IN |
Shipping Weight |
17.37 LBS |
Country of Origin |
Taiwan |
Shipping Height |
6.69 IN |
Shipping Length |
14.57 IN |
Shipping Width |
18.75 IN |
UPC |
095969527415 |
|
Cases
Product |
Price |
|
Fluke C1600
Catalog #: 2091049
Meter and Accessories Gear Box
|
$116.24
|
Accessories
Product |
Price |
|
Fluke 810PA
Catalog #: 3986002
AC Power Adapter with International Plug Set
|
$139.24
|
|
Fluke 810QDC
Catalog #: 3530837
Quick Disconnect Cable
|
$265.24
|
|
Fluke 810S
Catalog #: 3530828
Sensor for Fluke 810 Vibration Tester
|
$2,108.24
|
|
Fluke 810SMM
Catalog #: 3530862
Sensor Magnet Mount for Fluke 810 Vibration Analyzer
|
$351.24
|
|
Fluke 810SMP
Catalog #: 3530855
Sensor Mounting Pad, for 810 Model Handheld Vibration Tester, 10 Pack
|
$60.24
|
|
Fluke 810T
Catalog #: 3530819
Tachometer for 810 Vibration Tester
|
$219.24
|
|
Fluke SBP810
Catalog #: 3530843
Smart Battery Pack for Fluke 810 Vibration Analyzer
|
$411.24
|
|
|
|