Fluke 8846A/C 120V
Catalog #: 2675289
6.5 Digital Precision DMM, 24PPM w/ Accredited 17025 Calibration
- Overview
- Specifications
- Summary
- Accessories
Product Highlights
- 6.5 DIGIT PRECISION DMM, 24PPM USBMEM
- Includes 17025 Accredited Calibration
- Also measures capacitance and temperature
- USB memory drive port
- Basic V dc accuracy of up to 0.0024%
- 6.5 digit resolution
- 100 µA to 10 A current range, with up to 100 pA resolution
- Dual display
- 2 x 4 ohms 4-wire measurement technique
- Wide ohms range from 10Ω to 1 GΩ with up to 10 µΩ resolution
- Fluke 45 and Agilent 34401A emulation
- Both models measure frequency and period
- Trendplot paperless recorder mode, statistics, histogram
- Graphical display
- CAT I 1000 V, CAT II 600 V
Each Unit Includes
- Accredited 17025 Calibration Certificate
- Fluke TL71 Test Leads
- LCI Line Cord
- USB to RS232 Cable Adapter
- Statement of Calibration Practices
- WEEE Information Sheet
- Warranty Information
- Programmer, Users and Service Manuals (CD-ROM)
- FlukeView Forms – Basic for 8846
Summary Specifications |
Display |
VFD Dot Matrix |
Resolution |
6.5 Digits |
V DC |
Ranges |
100 mV to 1000V |
Max. Resolution |
100nV |
Accuracy |
0.0035 + 0.0005 |
V AC |
Ranges |
100 mV to 750 V |
Max. Resolution |
100 nV |
Accuracy |
0.06 + 0.03 |
Frequency |
3Hz to 300 kHz |
Resistance |
2x4 Wire |
Yes |
Ranges |
100 Ω to 100 MΩ |
Max. Resolution |
100 µΩ |
Accuracy |
0.010 + 0.001 |
A DC |
Ranges |
100 µA to 10 A |
Max. Resolution |
100 pA |
Accuracy |
0.050 + 0.005 |
A AC |
Ranges |
10 mA to 10 A |
Max. Resolution |
10 µA |
Accuracy |
0.10 + 0.04 |
Frequency |
3 Hz to 10 kHz |
Freq/Period |
Ranges |
3 Hz to 300 kHz |
Max Resolution |
1 µHz |
Accuracy |
0.01 % |
Continuity/ Diode Test |
Yes |
Capacitance |
Ranges |
- |
Max Resolution |
- |
Accuracy |
- |
Temperature |
Type |
- |
Range |
- |
Max. Resolution |
- |
Accuracy |
- |
Math Functions |
|
Zero, Min/Max/Average, Std Dev; mx+b |
dB/dBm |
Yes |
Advanced Functions |
Statisitics/Histogram |
Yes |
Trendplot |
Yes |
Limit Test |
Yes |
Input Output |
USB Memory |
- |
Real Time Clock |
- |
Interfaces |
RS 232, IEE-488.2, Ethernet |
Programming Languages/ Modes |
SCPI (IEEE-488.2), Agilent 34401A, Fluke 45 |
General |
Weight |
3.6 kg (8.0 lbs) |
Size (HxWxD) |
88 mm x 217 mm x 297 mm (3.46 in x 8.56 in x 11.7 in) |
Safety |
Designed to comply with IEC 61010-1 2000-1 ANSI/ISA-S82.01-1994, CAN/CSA-C22.2 No. 1010.1-92 CAT I 1000 V, Cat II 600 V |
Warranty |
One year |
Type |
Digital |
Style |
Bench |
Measures AC V |
Yes |
Measures DC V |
Yes |
Measures AC A |
Yes |
Measures DC A |
Yes |
True RMS |
Yes |
Maximum Voltage AC |
1000 V |
Minimum Voltage AC |
100 mV |
Resolution AC Volts |
100 nV (0.00010 mV) |
Maximum Voltage DC |
1000 V |
Minimum Voltage DC |
100 mV |
Resolution DC Volts |
100 nV (0.00010 mV) |
Maximum Current AC |
10 A |
Minimum Current AC |
100 uA (0.1 mA) |
Resolution AC Current |
100 pA (0.0000001 mA) |
Maximum Current DC |
10 A |
Minimum Current DC |
100 uA (0.1 mA) |
Resolution DC Current |
100 pA (0.0000001 mA) |
Basic Accuracy V DC |
0.0024 |
# Digit Display |
6.5+ |
Counts |
2000000 . |
Backlight |
No |
Manual/Autoranging |
Both |
Dual Display |
Yes |
Analog Bargraph on Display |
No |
Decibels |
No |
Resistance |
Yes |
Frequency |
Yes |
Continuity |
Yes |
Capacitance |
Yes |
Temperature |
Yes |
Diode Testing |
Yes |
CAT Rating |
II |
CAT Voltage |
1,000 V, 600 V |
Peak Hold |
No |
Overload Protector |
Yes |
Kelvin 4-Wire Measurement Capability |
Yes |
Intrinsically Safe |
No |
Wireless Display |
No |
Data Hold |
No |
Low-Pass Filter |
No |
|
Unique Features |
•6.5 digit resolution
•Basic V dc accuracy of up to 0.0024 %
•Dual display
•100 μA to 10 A current range, with up to 100 pA resolution
•Wide ohms range from 10 Ω to 1 GΩ with up to 10 μΩ resolution
•2 x 4 ohms 4-wire measurement technique
•Both models measure frequency and period
•8846A also measures capacitance and temperature
•USB memory drive port (8846A)
•Fluke 45 and Agilent 34401A emulation
•Graphical display
•Trendplot™ paperless recorder mode, statistics, histogram
•CAT I 1000 V, CAT II 600 V
•Three-year warranty |
Warranty |
1 YEARS |
Additional Info/Comments |
Includes:
TL71 Test Lead Set, Premium DMM
LCI Line Cord
USB to RS232 Cable Adapter
Statement of Calibration Practices
WEEE Information Sheet
Warranty Information
Programmer, Users and Service Manuals (CD-ROM)
FlukeView Forms – Basic for 8845/8846
FlukeView Forms Software Upgrade |
Calibration Included |
Factory Calibration |
Safety Approval |
CSA, UL |
Data Logging |
No |
Interfaces I/O |
Analog Output, LAN / Ethernet, RS-232, Analog Input , USB |
Storage |
USB Flash Drive |
Product Weight |
8 LBS |
Product Height |
3.46 IN |
Product Length |
11.7 IN |
Product Width |
8.56 IN |
Shipping Weight |
11 LBS |
Country of Origin |
United States |
Shipping Height |
9.84 IN |
Shipping Length |
18.11 IN |
Shipping Width |
16.14 IN |
UPC |
095969353885 |
|
Accessories
Product |
Price |
|
Fluke FVF-UG
Catalog #: 1576741
FlukeView Software
|
$184.24
|
|
Fluke TL71
Catalog #: 1274382
Premium Test Lead Set
|
$45.24
|
|
Fluke TL910
Catalog #: 1616632
Electronic Test Probes
|
$99.24
|
|
|
|