Fluke 8808A/SU 120V
Catalog #: 2802432
5.5 Digital Multimeter, SW and Cable
- Overview
- Specifications
- Summary
- Accessories
Product Highlights
- 5.5 digit resolution
- Basic V dc accuracy of 0.01%
- Dual display
- Dedicated dc leakage current measurement
- 2x4 ohms 4-wire measurement technique
- Six dedicated buttons for fast access to instrument setups
- Hi/Lo limit compare for Pass/Fail testing
Each Unit Includes
- Fluke TL71 Test Leads
- Meter
- Line Cord
- USB to RS232 Interface Adapter Cable
- FlukeView Forms Basic Software
- Statement of Calibration Practices
- WEEE Information Sheet
- Warranty Statement
- CD Rom with User Manual (English)
- Getting Started Guide (English, French, German, Spanish, Italian, Simplified Chinese, Japanese)
- FlukeView Forms basic software
- USB to RS-232 interface adapter cable
| Display |
VFD multi segment display, dual readings |
| Resolution |
5.5 digits |
| V dc |
Ranges: 200 mV to 1000 V
Max. Resolution: 1uV
Accuracy: 0.015 + 0.003 |
| V ac |
Ranges: 200 mV to 750 V
Max. resolution: 1uV
Accuracy: 0.2 + 0.05
Frequency: 20 Hz to 100 KHz |
| Resistance |
2x4 Wire: Yes Ranges: 200 Ω to 100 MΩ
Max. resolution: 1 mΩ
Accuracy: 0.02 + 0.003 |
| A dc |
Ranges: 200 µA to 10 A
Max. Resolution: 1 nA
Accuracy: 0.02 + 0.005 |
| A ac |
Ranges: 20 mA to 10 A
Max. Resolution: 100 uA
Accuracy: 0.3 + 0.06
Frequency: 20 Hz to 2 KHz |
| Frequency |
Ranges: 20 Hz to 1 MHz
Max. Resolution: 0.1 mHz
Accuracy: 0.01 % |
| Math Functions |
dB/dBm: Yes |
| Advanced Functions |
Limit compare test, with pass and fail indicators |
| Interfaces |
RS-232, USB with optional adapter |
| Programming Languages/Modes |
Simplified ASCII, Fluke 45 remote command emulation |
| Weight |
2.1 kg (4.6 lbs) |
| Size (HxWxD) |
88 mm x 217 mm x 297 mm (3.46 in x 8.56 in x 11.7 in) |
| Safety |
Designed to comply with EN 61010-1:2001, ANSI/ISA 61010-1 (S82.02.01):2004, UL 61010-1:2004, AN/CSA C22.2 No. 61010.1:2004 |
| Warranty |
One year |
| Type |
Digital |
| Style |
Bench |
| Measures AC V |
Yes |
| Measures DC V |
Yes |
| Measures AC A |
Yes |
| Measures DC A |
Yes |
| True RMS |
No |
| Maximum Voltage AC |
750 V |
| Minimum Voltage AC |
200 mV |
| Resolution AC Volts |
1 uV (0.001 mV) |
| Maximum Voltage DC |
1000 V |
| Minimum Voltage DC |
200 mV |
| Resolution DC Volts |
1 uV (0.001 mV) |
| Maximum Current AC |
10 A |
| Minimum Current AC |
20 mA |
| Resolution AC Current |
100 uA (0.1 mA) |
| Maximum Current DC |
10 A |
| Minimum Current DC |
200 uA (0.2 mA) |
| Resolution DC Current |
1 nA (0.000001 mA) |
| Basic Accuracy V DC |
0.015 |
| # Digit Display |
5.5 |
| Counts |
199999 . |
| Backlight |
No |
| Manual/Autoranging |
Both |
| Dual Display |
Yes |
| Analog Bargraph on Display |
No |
| Decibels |
No |
| Resistance |
Yes |
| Frequency |
Yes |
| Continuity |
Yes |
| Capacitance |
No |
| Temperature |
No |
| Diode Testing |
Yes |
| CAT Rating |
I |
| CAT Voltage |
1,000 V, 600 V |
| Peak Hold |
No |
| Overload Protector |
Yes |
| Kelvin 4-Wire Measurement Capability |
Yes |
| Intrinsically Safe |
No |
| Wireless Display |
No |
| Data Hold |
Yes |
| Low-Pass Filter |
No |
| |
| Unique Features |
•5.5 digit resolution
•Basic V dc accuracy of 0.015 %
•Dual display
•Dedicated dc leakage current measurement
•2x4 ohms 4-wire measurement technique
•Six dedicated buttons for fast access to instrument setups
•Hi/Lo limit compare for Pass/Fail testing |
| Warranty |
1 YEARS |
| Calibration Included |
Factory Calibration |
| Safety Approval |
CSA, UL |
| Data Logging |
No |
| Interfaces I/O |
Analog Output, RS-232, Analog Input |
| Product Weight |
4.6 LBS |
| Product Height |
3.46 IN |
| Product Length |
11.7 IN |
| Product Width |
8.56 IN |
| Shipping Weight |
10.47 LBS |
| Country of Origin |
China |
| Shipping Height |
11.02 IN |
| Shipping Length |
16.14 IN |
| Shipping Width |
14.17 IN |
|
Accessories
| Product |
Price |
 |
Fluke FVF-UG
Catalog #: 1576741
FlukeView Software
|
$184.24
|
 |
Fluke TL910
Catalog #: 1616632
Electronic Test Probes
|
$90.25
|
|
|
|