Fluke Norma Series power analyzers at a glance |
|
Norma 4000 |
Norma 5000 |
Number of Phases |
1 or 3 |
3, 4 or 6 |
Bandwidth |
DC to 3 MHz or dc to 10 MHz depending on input module |
Basic Accuracy |
0.2%, 0.1% or 0.03% depending on input modules |
Sampling Rate |
0.33 MHz or 1 MHz depending on input modules |
Voltage Input Range |
0.3 to 1000 V |
Current Input Range (direct, not via shunt) |
0.03 mA – 20 A depending on input module |
Display |
Color, 5.7“ / 144 mm - 320 x 240 pixel |
Fast Fourier Transformation (FFT) |
To the 40th harmonic |
RS232 Interface |
Standard |
PI1 Process Interface (8 analog / impulse inputs and 4 analog outputs) |
Optional |
IEEE 488/GPIB Interface |
Optional |
Fluke NormaView PC Software (for data download, analysis & report writing) |
Standard |
Basic Function |
Included functions |
- Fast Fourier Transformation (FFT)
- Digital Oscilloscope (DSO)
- Integration function (energy)
- Vector Display
- Recorder
- RAM data memory
- Configuration
|
Measured Values |
Working Temperature Range |
Non-gapping calculation of averaged values for each phase. In three phase system additionally calculation of total power and averaging of V and I of the three phases. The fundamental H01 will be calculated in synchronous mode also for these values.
Urms effective value, Urm rectified mean, Um mean value
Up-, Up+, Upp peak values
Ucf crest factor Ucf, Uff form factor
Ufc fundamental content
Uthd distortion factor DIN, IEC
Irms effective value, Irm rectified mean, Im mean value
Ip-, Ip+, Ipp peak values
Icf crest factor Icf, Iff form factor
Ifc fundamental content
Ithd distortion factor DIN, IEC
P active power [W]
Q reactive power [Var]
S apparent power [VA]
ë, cos. phase angular
Integral function for active power P, reactive power Q, apparent power S,
voltage (Um) and current (Im),
Number of digits 4 or 5 dependent on measured value.
|
Frequency and Synchronization |
Range |
DC and 0.2 Hz to sample rate |
Accuracy |
±0.01 % of measured value (reading) |
General Specifications |
- Channels which can be selected: all U/I or external input.
- One of three low pass filter with different frequencies can be switched into the signal.
- The frequency is always visible on the top of the screen.
- The BNC synchronization socket on backside of the instrument can be used either as input or output.
- The input signals can be measured up to the sample rate of the power phase. The maximum level must not be higher then 50V.
- The output signal is a pulsed 5Volts TTL signal (frequency depends on the measured synch frequency).
|
Power Phase Channels |
Range |
PP42 |
PP50 |
PP54 |
PP64 |
Accuracy |
0.2% (0.1% rd + 0.1 % rg) |
0.1% (0.05% rd + 0.05 % rg) |
0.1% (0.05% rd + 0.05 % rg) |
0.03% (0.02% rg + 0.01% rg) |
Current Range |
20 A |
10 A |
10 A |
10 A |
Sampling Rate |
341 kHz |
1 MHz |
341 kHz |
341 kHz |
Bandwidth |
3 MHz |
10 MHz |
3 MHz |
3 MHz |
Configuration Memory |
Memory for Configurations |
4 MB
Up to 15 user configurations can be saved into a permanent memory and reloaded later on. Changes that were not saved are lost after switching off the instrument. |
Memory for Settings |
Standard |
Ambient Conditions |
Working Temperature Range |
5 °C to 35 °C (41 °F to 95 °F) |
Storage Temperature Range |
-20 °C to 50 °C (-4 °F to 122 °F) |
Housing Material |
Fluke Norma Power Analyzers are extremely compact and equipped with a solid metal case to meet stringent EMC requirements. |
Climatic Class |
KYG DIN 40040, max. 85 % relative humidity, non-condensing. |
Power supply |
85 V ac to 264 V ac, 50 Hz to 60 Hz, dc 100 to 260 V, ca. 40 VA European plug with switch. Binding post for current available on some models. |
Measuring Inputs |
Safety sockets 4 mm, 2 for each input. External shunt connection over BNC socket. |
Operation |
Membrane keyboard with cursor – function keys and direct functions. |
Connections |
Rear panel of the 3-phase Analyzer |
Standards and Safety |
Electrical Safety |
EN 61010-1 / 2nd Edition 1000 V CAT II (600V CAT III)
Degree of pollution 2, safety Class I
EN 61558 for transformer
EN 61010-2-031/032 for accessories |
Maximum inputs |
For voltage inputs Measurement range 1000 Veff, 2 kVpeak
For voltage inputs Measurement range 1000 Veff, 2 kVpeak |
Test Voltage |
Net input case (protective conductor) |
1.5 KV AC |
Net connection Measurement input |
5.4 kV AC |
Measurement inputs Case |
3.3 kV AC |
Measurement input input |
5.4 kV |
Electromagnetic susceptibility |
Emission |
IEC 61326-1, EN 50081-1, EN 55011 Class B |
Immunity |
IEC 61326-1 / Annex A (industrial sector), EN 50082-1 |
Physical Dimensions |
Size |
Norma 4000 |
5.9 in x 9.3 in x 12.4 in (150 mm x 237 mm x 315 mm) |
Norma 5000 |
5.9 in x 17.6 in x 12.4 in (150 mm x 447 mm x 315 mm) |
Weight |
Norma 4000 |
Approx. 11 lb. (5 kg) |
Norma 5000 |
Approx. 15 lb. (7 kg) |