Fluke N4K 1PP54
Catalog #: 3889571
Norma 4000 1 Phase High Precision Power Analyzer with PP54 Channel
- Overview
- Specifications
- Summary
Product Highlights
- N4K 1PP54 Norma 4000 1 Phase High Precision Power Analyzer with PP54 Channel
- Compact design makes it easy to carry and saves working space.
- Simple user interface ensures easy, intuitive operation.
- A variety of standard configurations allows users to choose the exact functionality required for their unique application.
- Simultaneous parallel acquisition of all phases allows accurate viewing of dynamic events on all phases at exactly the same point in time.
- All inputs are galvanically isolated to avoid short circuits in all applications.
- Voltage, current and power harmonics measured up to the 40th harmonic for complete analysis.
- FFT analysis, vector diagram, and Digital Oscilloscope (DSO) mode included in the base unit for complete analysis capability.
- User-selectable average time – from 15ms up to 3600s – for dynamic measurements.
- 4 MB on-board memory (expandable to 128 MB) for storage of measured values.
- Fast and easy connection to a PC – RS232 and USB included as standard; optional IEEE488, Ethernet, or USB2.0.
- PI1 process interface to measure torque and speed with external sensors, plus four analog outputs for easy use on motor and drive applications.
- 341kHz or 1 MHz sample rates for detailed signal analysis.
- Bandwidth from dc to 3 MHz / 10 MHz for reliable measurement precision.
- Fluke NormaView PC software for data download, analysis & report writing.
Each Unit Includes
- Space for three power-phases and options
- Fluke NormaView PC software
- User’s manual
- Test certificate>
- >Calibration values
- Power supply cable
- 5.7“ / 144 mm color display
- RS232/USB interface for data download
General Specifications |
Number of Phases |
Fluke Norma 4000: |
1 to 3 |
Fluke Norma 5000: |
3, 4 or 6 |
Weight |
Fluke Norma 4000: |
Approx. 5 kg (11 lb.) |
Fluke Norma 5000: |
Approx. 7 kg (15 lb.) |
Size |
Fluke Norma 4000: |
150 mm x 237 mm x 315 mm
(5.9 in x 9.3 in x 12.4 in) |
Fluke Norma 5000: |
150 mm x 447 mm x 315 mm
(5.9 in x 17.6 in x 12.4 in) |
On-board Printer |
Fluke Norma 4000: |
No |
Fluke Norma 5000: |
Yes (optional) |
Display |
Color, 5.7“ / 144 mm - 320 x 240 pixel
User-selectable background lighting and contrast. |
Bandwidth |
dc to 3MHz or dc to 10MHz depending on input module |
Basic Accuracy |
0.2%, 0.1% or 0.03% depending on input modules |
Sampling Rate |
0.33 MHz or 1 MHz depending on input modules |
Voltage Input Range |
0.3 V to 1000 V |
Current Input Range (direct, not via shunt) |
0.03 mA to 20 A depending on input module |
Memory for Configurations |
4 MB |
Memory for Settings |
0.5 MB |
Fast Fourier Transformation (FFT) |
To the 40th harmonic |
RS232/USB Interface |
Standard |
PI1 Process interface (8 analog/impulse inputs and 4 analog outputs) |
Optional |
IEEE 488.2/GPIB interface (1 MBit/s Ethernet / 10 MBit/s or 100 MBit/s) |
Optional |
Fluke NormaView PC software (for data download, analysis & report writing) |
Standard |
Basic Functions |
Fast Fourier Transformation (FFT) |
Calculation of harmonics with graphical representation. Up to 3 bar graphs are displayed at the same time.
Measured values: U, I, P per phase
Order: 1st to 40th harmonics, maximum half sample frequency |
Digital Oscilloscope (DSO) |
Simultaneous display of up to 3 measured values on sample level. Quick view of curve form and distortion. |
Integration function (energy) |
Simultaneous display of up to 6 configurable numeric values. Start/Stop conditions and positive negative direction available. |
Vector Display |
Vector display of HO1 up to 6 signals. For easy testing of the right connection of the instrument and quick overview of the phase angle of each signal. |
Recorder |
Display of average values over time for trend determination. |
RAM data memory |
Storing of sample and average values; setting of start and stop conditions. From the RAM approximately 4 MB are available for the storage of measured values. |
Configuration |
Set up the analyzer to measure and display data in the format required. |
Ambient Conditions |
Working Temperature Range |
5 °C to 35 °C (41 °F to 95 °F) |
Storage Temperature Range |
-20 °C to 50 °C (-4 °F to 122 °F) |
Housing Material |
Fluke Norma Power Analyzers are extremely compact and equipped with a solid metal case to meet stringent EMC requirements. |
Climatic Class |
KYG DIN 40040, max. 85 % relative humidity, non-condensing. |
Power supply |
85 V ac to 264 V ac, 50 Hz to 60 Hz, dc 100 to 260 V, ca. 40 VA European plug with switch. Binding post for current available on some models. |
Measuring Inputs |
Safety sockets 4 mm, 2 for each input. External shunt connection over BNC socket. |
Operation |
Membrane keyboard with cursor – function keys and direct functions. |
Connections |
Rear panel of the 3-phase Analyzer |
Measured Values |
Non-gapping calculation of averaged values for each phase. In three phase system additionally calculation of total power and averaging of V and I of the three phases. The fundamental H01 will be calculated in synchronous mode also for these values. |
Urms effective value, Urm rectified mean, Um mean value |
Up-, Up+, Upp peak values |
Ucf crest factor Ucf, Uff form factor |
Ufc fundamental content |
Uthd distortion factor DIN, IEC |
Irms effective value, Irm rectified mean, Im mean value |
Ip-, Ip+, Ipp peak values |
Icf crest factor Icf, Iff form factor |
Ifc fundamental content |
Ithd distortion factor DIN, IEC |
P active power [W] |
Q reactive power [Var] |
S apparent power [VA] |
ë, cos. phase angular |
Integral function for active power P, reactive power Q, apparent power S, voltage (Um) and current (Im), |
Number of digits 4 or 5 dependent on measured value. |
Frequency and Synchronization |
Range |
DC and 0.2 Hz to sample rate |
Accuracy |
±0.01 % of measured value (reading) |
|
- Channels which can be selected: all U/I or external input.
- One of three low pass filter with different frequencies can be switched into the signal.
- The frequency is always visible on the top of the screen.
- The BNC synchronization socket on backside of the instrument can be used either as input or output.
- The input signals can be measured up to the sample rate of the power phase. The maximum level must not be higher then 50V.
- The output signal is a pulsed 5Volts TTL signal (frequency depends on the measured synch frequency).
|
Configuration Memory |
Up to 15 user configurations can be saved into a permanent memory and reloaded later on. Changes that were not saved are lost after switching off the instrument. |
Interface |
|
RS232 interface for upload of firmware and data exchange with the PC. A printer can be connected over an external converter. |
Options |
IEEE 488.2 / 1 MBit/s |
Ethernet / 10 MBit/s or 100 Mbit/s |
Standards and Safety |
Electrical Safety |
EN 61010-1 / 2nd Edition 1000 V CAT II (600V CAT III) |
Degree of pollution 2, safety Class I |
EN 61558 for transformer |
EN 61010-2-031/032 for accessories |
Maximum inputs |
For voltage inputs Measurement range 1000 Veff, 2 kVpeak |
For current inputs Measurement range 10 Aeff, 20 Apeak |
Test voltage |
Net input |
case (protective conductor): 1.5 KV AC |
Net connection |
Measurement input: 5.4 kV AC |
Measurement inputs |
Case: 3.3 kV AC |
Measurement input |
input: 5.4 kV |
Electromagnetic susceptibility |
Emission: |
IEC 61326-1, EN 50081-1, EN 55011 Class B |
Immunity: |
IEC 61326-1 / Annex A (industrial sector), EN 50082-1 |
Power Phase Channels |
PP42 |
Accuracy: |
0.2% (0.1% rd + 0.1 % rg) |
Current range: |
20 A |
Sampling rate: |
341 kHz |
Bandwidth: |
3 MHz |
PP50 |
Accuracy: |
0.1% (0.05% rd + 0.05 % rg) |
Current range: |
10 A |
Sampling rate: |
1 MHz |
Bandwidth: |
10 MHz |
PP54 |
Accuracy: |
0.1% (0.05% rd + 0.05 % rg) |
Current range: |
10 A |
Sampling rate: |
341 kHz |
Bandwidth: |
3 MHz |
PP64 |
Accuracy: |
0.03% (0.02% rg + 0.01% rg) |
Current range: |
10 A |
Sampling rate: |
341 kHz |
Bandwidth: |
3 MHz |
Power Measurement/Power Quality Analyzer Template |
Type (Power Quality) |
Single Phase |
Maximum Current AC |
10 A |
Maximum Current DC |
10 A |
Maximum Voltage AC |
1000 V |
Maximum Voltage DC |
1000 V |
True Power / Work ( W) |
Yes |
Apparent Power (VA) |
Yes |
Reactive Power (VAR) |
Yes |
Current Input Channels |
3 |
Voltage Input Channels |
3 |
Measurement Frequency (Power Quality) |
50 Hz, 60 Hz |
Display (Power Quality) |
Digital |
Alarms |
No |
Transient Capture |
Yes |
Minimum Transient Duration |
milli-seconds |
Displays Waveform |
No |
Energy |
Yes |
Phasor Diagrams |
No |
Power Factor (Power Quality) |
Yes |
Harmonics |
Yes |
Maximum Harmonics Range |
12 |
Current Clamps Included |
No |
Class A Compliant |
No |
Crest Factor |
Yes |
CAT Rating |
II |
CAT Voltage Rating (V) |
1000V, 600V |
GPS Location |
No |
Unique Features |
•Compact design makes it easy to carry and saves working space.
•Simple user interface ensures easy, intuitive operation.
•A variety of standard configurations allows users to choose the exact functionality required for their unique application.
•Simultaneous parallel acquisition of all phases allows accurate viewing of dynamic events on all phases at exactly the same point in time.
•All inputs are galvanically isolated to avoid short circuits in all applications.
•Voltage, current and power harmonics measured up to the 40th harmonic for complete analysis.
•FFT analysis, vector diagram, and Digital Oscilloscope (DSO) mode included in the base unit for complete analysis capability.
•User-selectable average time – from 15ms up to 3600s – for dynamic measurements.
•4 MB on-board memory (expandable to 128 MB) for storage of measured values. |
Warranty |
2 YEARS |
Additional Info/Comments |
•Fast and easy connection to a PC – RS232 and USB included as standard; optional IEEE488, Ethernet, or USB2.0.
•PI1 process interface to measure torque and speed with external sensors, plus four analog outputs for easy use on motor and drive applications.
•341kHz or 1 MHz sample rates for detailed signal analysis.
•Bandwidth from dc to 3 MHz / 10 MHz for reliable measurement precision.
•Fluke NormaView PC software for data download, analysis & report writing |
Calibration Included |
Factory Calibration |
Data Logging |
Yes |
Interfaces I/O |
Analog Output, Other, RS-232, Analog Input |
Storage |
Compact Flash |
Product Weight |
11 LBS |
Product Height |
5.9 IN |
Product Length |
12.4 IN |
Product Width |
9.3 IN |
Shipping Weight |
13.34 LBS |
ECCN Number |
3A992 |
Country of Origin |
Romania |
UPC |
095969577397 |
|
|
|
|