Fluke 3312-PR-TF-II
Catalog #: 4531784
Current Probe, Thin Flex
- Overview
- Specifications
- Summary
Product Highlights
- 3312-PR-TF-II Thin Flex Current Probe
- 5000A FLUKE 1750 THIN FLEXI 122CM (48IN)
- Designed for use with the Fluke 1750 Power Recorder
- Measure current from very low frequencies up to the 50th harmonic of a 50/60 Hz power supply
- Quick and easy installation in hard to reach areas and around large conductors
General Specifications |
Probe Cable Length |
24 in. (610 mm) 3310-PR-TF
48 in. (1220 mm) 3312-PR-TF |
Probe Cable Diameter |
0. 3 in. (8 mm) |
Transducer Bend Radius (min) |
1. 5 in. (38.1 mm) |
Output Cable |
2 core screened, 3 meters long, double insulated |
Output Connector |
LEMO 6 pin male connector |
Operating Temperature Range |
-4 to +1 58 °F (-20 to + 7 0 °C) (the temperature of the conductor under test shall not exceed 176 °F /80 °C) |
Storage Temperature Range |
-40 to 176 °F (-40 to + 80 °C) |
Operating Humidity |
15 % to 85 % rh (non condensing) |
Altitude |
max 6562 ft. (2000 m) |
Degree of ingress protection |
IP40 (60529) |
Electrical Specifications |
Measurement Range |
100 to 5000A (with a crest factor ≤ 3) |
Frequency Range |
40 Hz to 5 kHz |
Frequency Derating |
I x f ≤ 385 kA Hz |
Accuracy (@ 25 °C) |
± 1 % of reading |
Linearity (10 % to 100 % of range) |
±0.2 % of reading |
Temperature Coefficient |
±0.05 % of reading per °C |
Position Sensitivity (with cable > 25 mm from the coupling) |
±2 % of reading |
External Field (with cable > 200 mm from the head) |
±1 % of reading |
Working Voltage (see Safety Standards) |
1000 V ac rms or dc |
Country of Origin |
Bulgaria |
|
|
|
|