Fluke 3000 FC IND
Catalog #: 4465599
FC Wireless Industrial System
- Overview
- Specifications
- Summary
- Cases
- Accessories
Product Highlights
Fluke 3000 FC Wireless Digital Multimeter
- Save money and time by taking multiple measurements simultaneously
- Isolate interruptions or record signal fluctuations without even being there using the log function on the modules
- Work with fewer interruptions by recording multiple sessions before downloading
- Capture readings at different intervals, with user-set recording intervals from one second to one hour
- Choose the module(s) that work best for your applications—voltage, current, and temperature.
- View up to 10 live readings at once on the Fluke Connect™ mobile app
- View up to six live readings at once on a PC to get a complete understanding of the situation and download logging sessions (PC Adapter sold separately)
- Add the 3000 FC Digital Multimeter or Ti200/300/400 Infrared Camera to monitor modules on the move
- No more run-around. See multiple measurements in one place at the same time
- No more writing data down. Capture single or multiple logging sessions using the recording capability
- Avoid awkward or uncomfortable measurement positions. Set up the measurement once, step back and read it as many times as you want, when you want.
Fluke A3001 FC Wireless iFlex AC Current Module
- Measure up to 2500 A ac
- Use as a standalone meter or as part of the system
- Logging function for recording and saving up to
- 65,000 readings
- Inrush function
Fluke V3000 FC Wireless True-rms AC Voltage Module
- True-rms AC Voltage Module
- Measure up to 1000 V
- Use as a standalone meter or as part of the system
- Logging function for recording and saving up to 65,000 readings
Fluke Connect Features:
- Fluke Connect allows you to wirelessly transfer data from your existing Fluke tools to your smart phone
- Fits over the IR port of your existing Fluke tools
- Upgradeable by USB
- Immediately enables you to graph, save, and share the tool’s readings with your team from your smart phone
Supported smart phones:
- Android™ 4.3 & up
- iPhone® 4s & later
Each Unit Includes
- (1) 3000 FC Wireless Multimeter
- (1) Test lead set
- (1) Alligator clip set
- (3) A3001 Wireless iFlex AC Current Modules
- (3) iFlex i2500-10 Flexible Current Probe
- (1) V3000 FC Wireless AC Voltage Module
- (1) TL224 Test Lead set
- (1) AC285 Alligator Clip set
- (4) Magnetic hanging strap
- (1) PC3000 FC USB PC Adapter
Fluke 3000 FC Series Wireless Multimeter |
Detailed specifications (Not compatible with Fluke CNX test tools)
For all specifications: accuracy is specified for one year after calibration, at operating temperatures of 18 °C to 28 °C, with relative humidity at 0 % to 90 %. Accuracy specifications take the form of ± ([ % of Reading ] + [ Number of least significant digits ]).
|
AC voltage |
Range 1 |
Resolution |
Accuracy2,3,4 |
45 Hz to 500 Hz |
500 Hz to 1 kHz |
600.0 mV |
0.1 mV |
1.0 % + 3 |
2.0 % + 3 |
6000 V |
0.001 V |
1.0 % + 3 |
2.0 % + 3 |
60.00 V |
0.01 V |
1.0 % + 3 |
2.0 % + 3 |
600.0 V |
0.1 V |
1.0 % + 3 |
2.0 % + 3 |
1000 V |
1 V |
1.0 % + 3 |
2.0 % + 3 |
1 All ac voltage ranges are specified from 1 % of range to 100 % of range.
2 Crest factor of = 3 at full scale up to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V.
3 For non-sinusoidial waveforms, add ± (2 % of reading + 2 % full scale) typical, for crest factor up to 3.
4 Do not exceed 10 7 V-Hz. |
DC voltage, continuity, resistance, diode test and capacitance |
Function |
Range |
Resolution |
Accuracy |
mV |
600.0 mV |
0.1 mV |
0.09 % + 2 |
V |
6.000 V |
0.001 V |
0.09 % + 2 |
60.00 V |
0.01 V |
600.0 V |
0.1 V |
1000 V |
1 V |
0.15 % + 2 |
Ω |
600.0 Ω |
1 Ω |
Meter beeps at < 25 Ω, beeper detects opens or shorts of 250 us or longer. |
Diode test |
2.000 V |
0.001 V |
1 % + 2 |
µF |
1000 nF |
1 nF |
1.2 % + 2 |
10.00 µF |
0.01 µF |
100.0 µF |
0.1 µF |
9999 µF 1 |
1 µF |
10 % typical |
1 In the 9999 µF range for measurements to 1000 µF, the measurement accuracy is 1.2 % + 2. |
AC and DC current |
Function |
Range 1 |
Resolution |
Accuracy |
mA AC (45 Hz to 1 kHZ) |
60.00 mA |
0.01 mA |
1.5 % + 3 |
400.0 mA 3 |
0.1 mA |
mA DC 2 |
60.00 mA |
0.01 mA |
0.5 % + 3 |
400.0 mA 3 |
0.1 mA |
1All ac current ranges are specified from 5 % of range to 100 % of range.
2Input burden voltage (typical): 400 mA input 2 mV/m
3400.0 mA accuracy specified up to 600 mA overload. |
Frequency |
Range |
Resolution |
Accuracy 1 |
99.99 Hz |
0.01Hz |
0.1 % + 1 |
999.9 Hz |
0.1 Hz |
9.999 kHz |
0.001 kHz |
99.99 kHz |
0.01 kHz |
General specifications (Not compatible with Fluke CNX test tools) |
Maximum voltage between any terminal and earth ground |
1000 V dc or ac rms |
Ω fuse protection from A inputs |
0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only |
Display (LCD) |
Update rate: 4/sec
Votls, amps, ohms: 6000 counts
Frequency: 10,000 counts
Capacitance: 1,000 counts |
Battery type |
Three AA Alkaline batteries, NEDA 15A IEC LR6 |
Battery life |
250 hours minimum |
RF communications |
2.4 GHZ ISM Band |
RF communication range |
Open air, unobstructed: Up to 20m
Obstructed, sheetrock wall: Up to 6.5m
Obstructed, concrete wall, or steel electrical enclosure: Up to 3.5m |
Temperature |
Operating: -10 °C to 50 °C
Storage: -40 °C to 60 °C |
Temperature coefficient |
0.1 X (specified accuracy) /°C (<18 °C or >28 °C) |
Relative humidity |
0 % to 90 % (0 °C to 35 °C), 0 % to 75 % (35 °C to 40 °C), 0 % to 45 % (40 °C to 50 °C) |
Altitude |
Operating: 2,000 m
Storage: 12,000 m |
Electromagnetic compatibilty EMI, RFI, EMC, RF |
EN 61326-1:2006, EN 61326-2-2:2006. ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489 V1.8.1:2008, FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249, FCCID : FCC: T68-FDMMBLE IC: 6627A-FDMMBLE |
Safety compliance |
ANSI/ISA 61010-1 / (82.02.01): 3 rd edition
CAN/CSA-C22.2 No 61010-1-12: 3 rd edition
UL 61010-1: 3 rd edition
IEC/EN 61010-1:2010 |
Certifications |
CSA, FCC, CE |
Ingress Protection (IP) rating |
IP54 |
Pollution Degree |
2 |
Size (H x W x L) |
4.75 cm x 9.3 cm x 20.7 cm (1.87 in x 3.68 in x 8.14 in) |
Weight |
340 g (12 oz) |
Fluke A3001 FC Wireless iFlex AC Current Module
A3001 FC general specifications |
Range |
0.5 A to 2500 A AC |
Resolution |
0.1 A |
Accuracy |
3 % ± 5 digits (5 Hz to 500 Hz) |
Crest factor (50 Hz/60 Hz |
3.0 at 1100 A, 2.5 at 1400 A, 1.42 at 2500 A, add 2 % for C.F. > 2 |
LCD w/backlight |
3½ digits |
Log rate/interval |
1 sec minimum/adjustable by PC or front panel |
Battery type |
2 AA, NEDA 15 A, IEC LR6 |
Battery life |
400 hours |
Memory |
Record up to 65,000 readings |
RF communications |
2.4 GHZ ISM Band |
RF communication range |
Open air, unobstructed: Up to 20 m
Obstructed, sheetrock wall: Up to 6.5 m
Obstructed, concrete wall or steel electrical enclosure: Up to 3.5 m |
Operating temperature |
-10 °C to +50 °C |
Storage temperature |
-40 °C to +60 °C |
Temperature coefficient |
Add 0.1 X (specified accuracy)/ °C (<18 °C or >28 °C) |
Operating humidity |
without humidity/temperature: 246 x 161 x 47 mm
with humidity/temperature: 396 x 161 x 78 mm |
Altitude |
Operating: 2,000 m
Storage: 12,000 m |
EMC |
EN 61326-1:2006 |
Safety compliance |
IEC 61010-1, 600 V CAT IV/1000 V CAT III, 3rd edition Pollution Degree 2 |
Safety rating |
CAT IV 600 V, CAT III 1000 V |
Certifications |
CSA, CE, FCC: T68-FBLE IC: 6627A-FBLE |
Ingress Protection (IP) rating |
IP42 |
Pollution degree |
2 |
Jaw opening |
25.4 cm (10 in) coil |
Size (HxWxD) |
16.5 cm x 6.35 cm x 1.4 cm (6.5 in x 2.5 in x 1.4 in) |
Weight |
.22 kg (8 oz) |
(Not compatible with Fluke CNX test tools) |
Fluke V3000 FC Wireless True-rms AC Voltage Module
V3000 FC General Specifications |
LCD w/backlight |
3½ digits, 6000 counts, updates 4/sec |
Battery type |
2 AA, NEDA 15 A, IEC LR6 |
Battery life |
400 hours |
Memory |
Record up to 65,000 readings |
RF communications |
2.4 GHZ ISM Band |
RF communication range |
Open air, unobstructed: Up to 20 m
Obstructed, sheetrock wall: Up to 6.5 m
Obstructed, concrete wall or steel electrical enclosure: Up to 3.5 m |
Operating temperature |
-10 °C to +50 °C |
Storage temperature |
-40 °C to +60 °C |
Temperature coefficient |
0.1 X (specified accuracy)/°C (< 18 °C or > 28 °C) |
Operating humidity |
90 % at 35 °C, 45 % at 40 °C, 45 % at 50 °C |
Altitude |
Operating: 2,000 m
Storage: 12,000 m |
EMC |
EN 61326-1:2006 |
Safety compliance |
ANSI/ISA 61010-1 / (82.02.01): 3rd edition
CAN/CSA-C22.2 No 61010-1-12: 3rd edition
UL 61010-1: 3rd edition
IEC/EN 61010-1:2010 |
Safety rating |
CAT IV 600 V, CAT III 1000 V |
Certifications |
CSA, CE, FCC: T68-FBLE IC: 6627A-FBLE |
Ingress Protection (IP) rating |
IP42 |
Pollution degree |
2 |
Size (HxWxD) |
16.5 cm x 6.35 cm x 1.4 cm (6.5 in x 2.5 in x 1.4 in) |
Weight |
.22 kg (8 oz) |
(Not compatible with Fluke CNX test tools) |
Multimeters Template |
Type |
Digital |
Style |
Hand-Held |
Measures AC V |
Yes |
Measures DC V |
Yes |
Measures AC A |
Yes |
Measures DC A |
Yes |
Maximum Voltage AC |
1000 V |
Minimum Voltage AC |
0.1 mV |
Resolution AC Volts |
0.1 mV |
Maximum Voltage DC |
1000 V |
Minimum Voltage DC |
0.1 mV |
Resolution DC Volts |
0.1 mV |
Maximum Current AC |
2500 A |
Minimum Current AC |
0.01 mA |
Resolution AC Current |
0.01 mA |
Maximum Current DC |
400 mA (0.4 A) |
Minimum Current DC |
0.01 mA |
Resolution DC Current |
0.01 mA |
Basic Accuracy V DC |
0.09 % + 2 |
Backlight |
Yes |
Dual Display |
Yes |
Decibels |
No |
Resistance |
Yes |
Frequency |
Yes |
Capacitance |
Yes |
Temperature |
Yes |
Diode Testing |
Yes |
CAT Voltage |
1,000 V, 600 V |
Intrinsically Safe |
No |
Kelvin 4-Wire Measurement Capability |
No |
Wireless Display |
No |
Safety Approval |
CE, CSA |
Product Weight |
340 LBS |
Product Height |
1.87 IN |
Product Length |
8.17 IN |
Product Width |
3.68 IN |
Country of Origin |
China |
UPC |
095969724180 |
|