Megger MIT210-EN
Catalog #: Megger MIT210-EN
Insulation/Continuity Tester with Digital Display and Analog Arc, 1000V
- Overview
- Specifications
- Summary
- Accessories
Product Highlights
- Utilizes 1000 V test range
- Performs insulation measurements up to 1000 Megaohms
- Carries out continuity testing at 200 mA down to 0.01 ohm
- Inhibits testing on circuits over 50 V on both continuity and insulation test ranges
- Generates warning when circuits are in excess of 25 V
- Automatic continuity testing allows for hands-free operation
- Test lead zero allows compensation for test lead resistance up to 10 ohms
- Powered by alkaline or rechargeable batteries
- Automatic power-off function helps preserve battery power
- Combined digital display and analog arc
- CAT III 600 V safety rating
- Conforms to EN 61557
Each Unit Includes
- 1 - 1000 V Insulation and Continuity Tester (MIT210-EN)
- 1 - Test Lead Set with Crocodile Clips (1002-001)
- 1 - Carrying Case (1007-168)
Insulation Ranges |
|
Nominal Test Voltage: |
1000 V |
Measuring Ranges: |
10 K-ohm - 1000 M-ohm on all ranges |
Terminal Voltage on open Circuit: |
-0% +25% of rated voltage |
Short Circuit Current: |
2mA, 1mA - 10mA |
Test Current On Load: |
>1 mA at minimum pass values of insulation |
Accuracy: |
±3% of reading ±2 digits up to 10 M-ohm
±5% of reading ±2 digits up to 100 M-ohm
±30% of reading up to 1000 M-ohm |
Continuity Ranges |
|
Measuring Range: |
0.01 ohms to 100.0 ohms (0 - 50 ohms on analog scale) |
Accuracy: |
±0.01 ohms to 9.99 ohms
±3%
±2 digits 10.0 ohms to 99.9 ohms ±5%
±2 digits |
Open Circuit Voltage: |
5V ±1V |
Test Current: |
205 mA, ±5 mA @ (0 - 10 ohms) > 20mA up to 100 ohms |
Zero Offset Adjust: |
0 to 9.99 ohms |
General |
|
Power Supply: |
6 x 1.5 V Alkaline cells IEC LR6 type |
Battery Life: |
Typically up to 3500, 5 second tests |
Operating Temperature: |
-10ºC to 55ºC |
Operating Humidity: |
93% Relative Humidity at 40ºC max |
Storage Temperature: |
-25ºC to 65ºC |
Dimensions: |
195mm (L) x 98mm (D) x 40mm (H) |
Weight: |
550g |
Type |
Battery |
IR Test Voltage |
1,000 V |
Maximum Insulation Resistance |
1 G Ohms |
Minimum Insulation Resistance |
10 K Ohms (0.00001 G Ohms) |
Variable Incremental Voltage |
No |
Display (Megohmmeter) |
Digital |
Continuity Test |
Yes |
Live Circuit Voltage Detection |
Yes |
Power Supply |
Battery |
Timer |
No |
CAT Rating |
III |
CAT Voltage |
600 V |
Unique Features |
Safety
Every Megger instrument is designed with safety as its primary objective. All instruments meet or exceed the requirements of safety directive IEC 61010 and EN61557 for insulation and continuity testing..
Default fault meter
A built-in voltmeter automatically switches in when the instrument is connected to a circuit with an AC or DC voltage greater than 25 V
.
Insulation Test inhibit
Circuits in excess of 25 V will generate a voltage warning. Circuits over 50 V will inhibit testing of the insulation, protecting the operator and the instrument from injury or damage.
600V CATIII
The MIT200 series has been designed for use on
applications up to 600V CATIII. |
Warranty |
3 YEARS |
Calibration Included |
None |
Power Supply Voltage |
Battery Powered |
Data Logging |
No |
IP Rating |
IP40 |
Product Weight |
1.2 LBS |
Battery Type |
AA |
Product Height |
1.6 IN |
Product Length |
7.7 IN |
Product Width |
3.9 IN |
Shipping Weight |
3.5 LBS |
ECCN Number |
EAR99 |
Country of Origin |
United Kingdom |
|
Accessories
Product |
Price |
 |
Megger CB101
Catalog #: 6311-077
Calibrated Check Box for 5kV Insulation Tester
|
$1,045.23
|
|
|
|