Fluke T+PRO
Catalog #: 2548117
Electrical Tester
- Overview
- Specifications
- Summary
Product Highlights
- Backlit LCD display for easier viewing
- Display resolution of 0.1 V, ideal for troubleshooting low-voltage lighting
- Resistance (Ohms) to 9.99 kOhms
- Rotary Field Indication
- Display Hold for easier viewing in hard-to-test areas
- 3 forms of ac/dc voltage indication: light, sound, and vibration for added user protection and convenience
- Detect live voltage even when the batteries are dead
- Extra heavy-duty, replaceable test leads for more flexibility and durability
- CAT IV 600 V, CAT III 1000 V rated for added user protection
- Continuity beeper
- Bright LED flashlight for work in poorly lit areas
- GFCI Trip
- On/Off switchable beeper, selectable according to your environment
- Compliant with latest NFPA 70E recommendations
- Replaceable test probes for added flexibility and convenience
- Convenient probe storage on the back
- Probe holder for easier testing
- Hazardous voltage warning light for added user protection
- Test lead strap included for better test lead management
- AC/DC Voltage: 12 V – 600 V on LED bar, 10.2 V – 600 V on LCD
- Auto-off saves battery power
- 2-year warranty
Each Unit Includes
- TP2 Test Probes
- User Manual
- Test Lead Wrap
- 2 AAA Batteries
| Temperature |
Operating: -10 C to 55 C (14 F to 131 F)
Storage: -30 C to 60 C (- 22 F to 140 F) |
| Relative humidity |
0 C to 30 C (3 F to 86 F): 90 %
30 C to 40 C (86 F to 104 F): 75 %
40 C to 50 C (104 F to 1 F): 45 % |
| Altitude |
Operating: 2,000 m (approx. 6,561.6 ft
Storage: 10,000 m (approx. 3 ,808.4 ft) |
| Battery type/life |
AAA (2); 40 hours |
| Shock, vibration |
Sinusoidal vibration per MIL-PRF- 8800F for a Class instrument |
| Safety |
ISA-8 .0 .01 (IEC 61010-1 Mod) Second Edition, CAN/CSA-C . No. 61010-1
Second Edition, IEC 61010 - 1 to 1000 V CAT III/600 V CAT IV
Compliance to NFPA 70E1 |
| AC Bandwidth |
45 Hz to 66 Hz |
| Maximum working voltage |
1000 V ac/dc |
| Maximum measurable voltage |
600 V ac/dc |
| Duty cycle |
Indefinitely for voltages up to 240 V.
For voltages between 40 V and 600 V the duty cycle is 30 s on / 300 s off.
For voltages above 40 V the tester must connect to a voltage source only for a MAXIMUM of 30 s and then disconnect for a MINIMUM of 300 s. |
| Voltage hazard LED |
LEDs turn on at voltages > 30 V ac/dc + 35 % |
| LED voltage indication levels |
1 V, 4 V, 48 V, 1 0 V, 08 V, 40 V, 77 V, 480 V, 600 V |
| LED voltage indication levels for Canadian version |
1 V, 4 V, 48 V, 1 0 V, 08 V, 40 V, 347 V, 480 V, 600 V |
| LEDs |
LEDs turn on between 70 % and 85 % of the indicated voltage on the LED, except for the 1 V LED which turns on between 50 % and 100 %. |
| Accuracy |
AC voltage: + (3 % rdg + digits)
DC voltage: + (2 % rdg + digits)
Resistance: + (5 % rdg + 3 digits) |
| LCD Resolution |
0.1 V for voltages < 50 V, 1 V for voltages >50 V
0.01 k ¸ for resistance measurement (For T+PRO Only) |
| GFCI Test current |
100 V - 00 V at 0 mA - 35 mA for 1 s |
| Standard input test current |
< 5 mA |
| Size (H x W x L) |
1.3 in x .15 in x 7.6 in (3.3 cm x 5.46 cm x 19.3 cm ) |
| Weight |
9.9 oz (0.28 kg) |
| Voltage / Continuity and Non-Contact Testers/Voltage and Continuity Testers Template |
| Type (Voltage Testers) |
Contact |
| Style (Voltage Testers) |
Hand Held |
| Voltage Tested |
AC/DC |
| AC Voltage |
600 VAC |
| DC Voltage |
600 VDC |
| Continuity |
Yes |
| Solenoid Tester |
No |
| Current Measurement |
Yes |
| Resistance Measurement |
Yes |
| Polarity Indication |
No |
| Vibration Indiciation |
Yes |
| Diode Testing |
No |
| Visual Alarm |
No |
| Audible Alarm |
Yes |
| CAT Voltage Rating |
III, IV |
| CAT Voltage Rating (V) |
1000V, 600V |
| Safety Voltage Rating |
1000V, 600V |
| Unique Features |
•Backlit LCD display for easier viewing
•Display resolution of 0.1 V, ideal for troubleshooting low-voltage lighting
•Resistance (Ohms) to 9.99 kOhms
•Rotary Field Indication
•Display Hold for easier viewing in hard-to-test areas
•3 forms of AC/DC voltage indication: light, sound, and vibration for added user protection and convenience
•Detect live voltage even when the batteries are dead
•Extra heavy-duty, replaceable test leads for more flexibility and durability
•CAT IV 600 V, CAT III 1000 V rated for added user protection
•Continuity beeper
•Bright LED flashlight for work in poorly lit areas
•GFCI Trip
•On/Off switchable beeper, selectable according to your environment
•Compliant with latest NFPA 70E recommendations*
•Replaceable test probes for added flexibility and convenience
•Convenient probe storage on the back
•Probe holder for easier testing
•Hazardous voltage warning light for added user protection
|
| Warranty |
2 YEARS |
| Calibration Included |
None |
| Power Supply Voltage |
Battery Powered |
| Safety Approval |
CSA |
| Data Logging |
No |
| Interfaces I/O |
Analog Output, Analog Input |
| Product Weight |
0.62 LBS |
| Battery Type |
AAA |
| Product Height |
1.3 IN |
| Product Length |
7.6 IN |
| Product Width |
2.15 IN |
| Shipping Weight |
0.66 LBS |
| ECCN Number |
3A992 |
| Country of Origin |
China |
| Shipping Height |
2 IN |
| Shipping Length |
8 IN |
| Shipping Width |
3 IN |
| UPC |
095969327923 |
|
|
|
|