Fluke T+PRO-1AC KIT
Catalog #: 2796187
Electrical Tester and AC Voltage Detector Kit
- Overview
- Specifications
- Summary
Product Highlights
Fluke T+Pro:
- Safer than traditional solenoid testers
- 3 forms of ac/dc voltage detection: lights, beeper, vibration for added user protection and convenience
- Still indicates live voltage without battery power for added user protection
- Backlit LCD display for easier viewing
- Resistance, Rotary Field Indication and Display Hold
- Extra-heavy-duty, replaceable test leads for added durability
- CAT IV 600V, CAT III 1000V rated for added user protection
- Continuity beeper, GFCI Trip, Flashlight
- Replaceable test probes for added convenience
- Probe storage on back for added convenience
- Probe holder for easier testing
- Hazardous voltage warning light for added user protection
- Test lead strap included for better test lead management
- AC/DC Voltage: 12 V-600 V on LED bar, 10.2 V-600 V on LCD
- LCD Resolution: 0.1 V for voltages < 50 V, 1V for voltages >= 50 V off to save battery power
- 2-year warranty
Fluke 1AC-II:
- Voltbeat technology and continuous self-test — so you always know it’s working
- Upon detection, tip glows and beeper sounds
- CAT IV 1000 V for added protection
- Expanded range: 90 V to 1000 V AC or 200 V to 1000 V AC depending on model
- 20 V to 90 V AC control circuit model also available
- Two-year warranty
| T+ Pro |
| Temperature |
Operating: -10 C to 55 C (14 F to 131 F)
Storage: -30 C to 60 C (- 22 F to 140 F) |
| Relative humidity |
0 C to 30 C (3 F to 86 F): 90 %
30 C to 40 C (86 F to 104 F): 75 %
40 C to 50 C (104 F to 1 F): 45 % |
| Altitude |
Operating: 2,000 m (approx. 6,561.6 ft
Storage: 10,000 m (approx. 3 ,808.4 ft) |
| Battery type/life |
AAA (2); 40 hours |
| Shock, vibration |
Sinusoidal vibration per MIL-PRF- 8800F for a Class instrument |
| Safety |
ISA-8 .0 .01 (IEC 61010-1 Mod)
Second Edition, CAN/CSA-C . No. 61010-1
Second Edition, IEC 61010 - 1 to 1000 V
CAT III/600 V CAT IV
Compliance to NFPA 70E1 |
| AC Bandwidth |
45 Hz to 66 Hz |
| Maximum working voltage |
1000 V AC/DC |
| Maximum measurable voltage |
600 V AC/DC |
| Duty cycle |
Indefinitely for voltages up to 240 V.
For voltages between 40 V and 600 V the duty cycle is 30 s on / 300 s off.
For voltages above 40 V the tester must connect to a voltage source only for a MAXIMUM of 30 s and then disconnect for a MINIMUM of 300 s. |
| Voltage hazard LED |
LEDs turn on at voltages > 30 V ac/dc + 35 % |
| LED voltage indication levels |
1 V, 4 V, 48 V, 1 0 V, 08 V, 40 V, 77 V, 480 V, 600 V |
| LED voltage indication levels for Canadian version |
1 V, 4 V, 48 V, 1 0 V, 08 V, 40 V, 347 V, 480 V, 600 V |
| LEDs |
LEDs turn on between 70 % and 85 % of the indicated voltage on the LED, except for the 1 V LED which turns on between 50 % and 100 %. |
| Accuracy |
AC voltage: + (3 % rdg + digits)
DC voltage: + (2 % rdg + digits)
Resistance: + (5 % rdg + 3 digits) |
| LCD Resolution |
0.1 V for voltages < 50 V, 1 V for voltages > 50 V
0.01 k ¸ for resistance measurement (For T+PRO Only) |
| GFCI Test current |
100 V - 00 V at 0 mA - 35 mA for 1 s |
| Standard input test current |
< 5 mA |
| Size (H x W x L) |
1.3 in x .15 in x 7.6 in (3.3 cm x 5.46 cm x 19.3 cm ) |
| Weight |
9.9 oz (0.28 kg) |
| 1AC-II |
| Operating principle |
Senses the steady state electrostatic ?eld produced by ac voltage through insulation without requiring contact to the bare conductor. A red glow at the tip and a beeping noise (if not switched OFF) indicates the presence of voltage. |
| Voltage sensing ranges |
Nominally, 90 V AC to 1000 V AC or 200 V AC to 1000 V AC depending on model, 45 Hz to 405 Hz; also a 20 V to 90 V control circuit model |
| Detector tip style |
Blade or round, depending on model |
| Light source |
One high intensity red LED |
| Agency Approvals |
c CSA us, CE, TUV, C-Tick |
| Safety Rating |
1000 V, CAT IV |
| IP Rating |
IP 40 |
| Operating temperature |
-10 °C to 50 °C |
| Operating humidity ranges |
0 % to 95 % (0 °C to 30 °C)
0 % to 75 % (30 °C to 40 °C)
0 % to 45 % (40 °C to 55 °C) |
| Operating Altitude |
3000 meters |
| Batteries |
2 AAA alkaline batteries included |
| Voltage / Continuity and Non-Contact Testers/Voltage and Continuity Testers Template |
| Type (Voltage Testers) |
Contact, Non-Contact |
| Style (Voltage Testers) |
Hand Held |
| Voltage Tested |
AC, DC |
| AC Voltage |
1000 VAC |
| DC Voltage |
1000 VDC |
| Continuity |
Yes |
| Solenoid Tester |
No |
| Current Measurement |
Yes |
| Resistance Measurement |
Yes |
| Polarity Indication |
No |
| Vibration Indiciation |
Yes |
| Diode Testing |
No |
| Visual Alarm |
Yes |
| Audible Alarm |
Yes |
| CAT Voltage Rating |
I, II, III, IV |
| CAT Voltage Rating (V) |
1000V, 600V |
| Warranty |
2 YEARS |
| Power Supply Voltage |
Battery Powered |
| Safety Approval |
CSA |
| Data Logging |
No |
| Battery Type |
AAA |
| Country of Origin |
N/A |
|
|
|
|