Fluke Calibration 5615-12-D
Catalog #: 3002846
Secondary Reference PRT Probe, 100 OHM (1/4 X 12 INCH), D = 5-pin DIN for Tweener Thermometers
- Overview
- Specifications
- Summary
- Cases
Product Highlights
- 5615-12-D (5-pin DIN for Tweener Thermometers)
- 6.35 mm x 305 mm
- Affordable wide-range accuracy
- Calibrated accuracy ± 0.012 °C at 0 °C
- Reference-grade platinum sensing element
- NVLAP-accredited calibration included, lab code 200706-0
Each Unit Includes
- Coefficient Sheet
- User Manual CD
- Certification Sheets
Specifications |
Temperature range |
and : –200 °C to 420 °C
: –200 °C to 300 °C |
Nominal resistance at 0 °C |
100 Ω ± 0.10 Ω |
Temperature coefficient |
0.0039250 Ω/Ω/°C |
Accuracy[1] |
± 0.024 °C at –200 °C
± 0.012 °C at 0 °C
± 0.035 °C at 420 °C |
Short-term repeatability[2] |
± 0.009 °C at 0.010 °C |
Drift[3] |
± 0.007 °C at 0.010 °C |
Sensor length |
28 mm (1.1 in) |
Sensor location |
6.9 mm ± 3.3 mm from tip (0.27 in ± 0.13 in) |
Sheath dimensions |
: 152 mm x 4.76 mm (6.0 in x 0.188 in)
: 229 mm x 4.76 mm (9.0 in x 0.188 in)
: 305 mm x 6.35 mm (12.0 in x 0.250 in) |
Sheath diameter tolerance |
± 0.127 mm (± 0.005 in) |
Sheath material |
Inconel™ 600 |
Minimum insulation resistance |
1000 MΩ at 23 °C |
Transition junction temperature range[4] |
–50 °C to 200 °C |
Transition junction dimensions |
71 mm x 13 mm dia (2.8 in x 0.5 in) |
Maximum immersion length |
: 102 mm (4 in)
: 178 mm (7 in)
: 254 mm (10 in) |
Response time[5] |
9 seconds typical |
Self heating (in 0 °C bath) |
50 mW/°C |
Lead-wire cable type |
PTFE insulated with PTFE jacket, 22 AWG |
Lead-wire length |
183 cm (72 in) |
Lead-wire temperature range |
–50 °C to 200 °C |
Calibration |
NVLAP-accredited calibration included, lab code 200706-0. Please see calibration uncertainty table and its explanation of changeable uncertainties. |
[1] Includes calibration and 100 hr drift (k=2)
[2] Three thermal cycles from min to max temp, includes hysteresis, 95 % confidence (k=2)
[3] After 100 hrs at max temp, 95 % confidence (k=2)
[4] Temperatures outside this range will cause irreparable damage. For best performance, transition junction should not be too hot to touch.
[5] Per ASTM E 644
|
NVLAP† Calibration Uncertainty |
Temperature |
Expanded Uncertainty (k=2) |
–196 °C |
0.024 °C |
–38 °C |
0.011 °C |
0 °C |
0.010 °C |
200 °C |
0.018 °C |
420 °C‡ |
0.029 °C |
Note: Calibration uncertainties depend on the uncertainties of the lab performing the calibration. Subsequent calibrations of this probe performed with different processes, at different facilities, or with changed uncertainty statements may state different uncertainties. †Lab code 200706-0 ‡5615-6 excluded |
|
Fluke Calibration Platinum Resistance Thermometers (PRTs) |
Model |
Range |
Size |
Basic Accuracy† |
Platinum Resistance Thermometer: Secondary Standard PRT |
5608-9-X |
–200 to 500 °C |
9 in x 1/8 in |
Select from available calibration options |
5608-12-X |
–200 to 500 °C |
12 in x 1/8 in |
5609-12-X |
–200 to 670 °C |
12 in x 1/4 in |
5609-15-X |
–200 to 670 °C |
15 in x 1/4 in |
5609-20-X |
–200 to 670 °C |
20 in x 1/4 in |
5609-300-X |
–200 to 670 °C |
300 mm x 6 mm |
5609-400-X |
–200 to 670 °C |
400 mm x 6 mm |
5609-500-X |
–200 to 670 °C |
500 mm x 6 mm |
5626 |
–200 °C to 661 °C |
305 or 381 x 6.35 mm (12 or 15 x 0.25 in |
±0.007 °C at 0 °C |
Platinum Resistance Thermometer: Secondary Reference PRT |
5616-12 |
–200 °C to 420 °C |
6.35 mm x 298 mm (0.250 x 11.75 in) |
± 0.010 °C at 0.010 °C |
5615-6 |
–200 to 300 °C |
4.76 mm x 152 mm (0.188 x 6.0 in) |
± 0.013 °C at 0.010 °C |
5615-9 |
–200 °C to 420 °C |
4.76 mm x 229 mm (0.188 x 9.0 in) |
± 0.013 °C at 0.010 °C |
>5615-12 |
–200 °C to 420 °C |
6.35 mm x 305 mm (0.250 x 12.0 in) |
± 0.013 °C at 0.010 °C |
Platinum Resistance Thermometer: Precision Industrial PRT |
5627A-6 |
–200 °C to 300 °C |
152 x 4.7 mm (6 x 0.187 in) |
±0.05 °C at 0 °C |
5627A-9 |
–200 °C to 300 °C |
229 x 4.7 mm (9 x 0.187 in) |
±0.05 °C at 0 °C |
5627A-12 |
–200 °C to 420 °C |
305 x 6.35 mm (12 x 0.25 in) |
±0.05 °C at 0 °C |
Platinum Resistance Thermometer: Fast Response PRT |
>5622-05 |
–200 °C to 350 °C |
100 x 0.5 mm |
±0.04 °C at 0 °C |
>5622-10 |
–200 °C to 350 °C |
100 x 1.0 mm |
±0.04 °C at 0 °C |
>5622-16 |
–200 °C to 350 °C |
200 x 1.6 mm |
±0.04 °C at 0 °C |
>5622-32 |
–200 °C to 350 °C |
200 x 3.2 mm |
±0.04 °C at 0 °C |
Platinum Resistance Thermometer: Small Diameter Industrial PRTs |
5618B-6 |
–200 °C to 300 °C |
152 x 3.2 mm (6 x 0.125 in) |
±0.05 °C |
5618B-9 |
–200 °C to 500 °C |
229 x 3.2 mm (9 x 0.125 in) |
±0.05 °C |
5618B-12 |
–200 °C to 500 °C |
305 x 3.2 mm (12 x 0.125 in) |
±0.05 °C |
Platinum Resistance Thermometer: Full Immersion PRTs |
5606 Immersion PRT |
–200 to 160 °C |
50 x 3.1 mm ( 2 x 1/8 in) |
±0.05 °C |
5607 Immersion PRT |
0 to 450 °C |
75 x 3.1 mm (3 x 1/8 in) |
±0.055 °C |
5623B Freezer Probe |
–100 °C to 156 °C |
152 x 6.35 mm (6 x 0.25 in) |
±0.05 °C |
Thermistors |
Thermistor: Standards |
5640 |
0 °C to 60 °C |
229 x 6.35 mm (9 x 0.25 in) |
±0.0015 °C |
5641 |
0 °C to 60 °C |
114 x 3.2 mm (4.5 x 0.125 in) |
±0.001 °C |
5642 |
0 °C to 60 °C |
229 x 3.2 mm (9 x 0.125 in) |
±0.001 °C |
5643 |
0 °C to 100 °C |
114 x 3.2 mm (4.5 x 0.125 in) |
±0.0025 °C |
5644 |
0 °C to 100 °C |
229 x 3.2 mm (9 x 0.125 in) |
±0.0025 °C |
Thermistor: Secondary Probes |
5610 |
0 °C to 100 °C |
152 or 229 x 3.2 mm (6 or 9 x 0.125 in) |
±0.01 °C |
5611A |
0 °C to 100 °C |
1.5 mm (0.06 in) tip dia. |
±0.01 °C |
5611T |
0 °C to 100 °C |
28 x 3 mm (1.1 x 0.12 in) |
±0.01 °C |
†“Basic Accuracy” includes calibration uncertainty and short-term repeatability. It does not include long-term drift.
X = termination. Specify A (INFO-CON for 914X), B (bare wire), D (5-pin DIN for Tweener Thermometers), G (gold pins), I (INFO-CON for 1521 or 1522), J (banana plugs), L (mini spade lugs), M (mini banana plugs), P (INFO-CON for 1523 or 1524), or S (spade lugs). |
Accessories/Probes/Temperature Probes Template |
Application/Properties |
Gas/Air, General, Immersion, Piercing, Pipe, Surface |
Max Temperature |
420 C |
Min Temperature |
-200 C (-328 F) |
Wire Termination |
Other |
Insulation Material |
Other |
Probe Length |
12 IN |
Lead Length |
72 IN (25.40 MM) |
Unique Features |
Temperature range
5615-12 and 5615-9: –200 °C to 420 °C
5615-6: –200 °C to 300 °C
Nominal resistance at 0 °C 100 Ω ± 0.10 Ω
Temperature coefficient 0.0039250 Ω/Ω/°C
Accuracy
± 0.024 °C at –200 °C
± 0.012 °C at 0 °C
± 0.035 °C at 420 °CC
Short-term repeatability[2] ± 0.009 °C at 0.010 °C
Drift ± 0.007 °C at 0.010 °C
Sensor length 28 mm (1.1 in)
Sensor location 6.9 mm ± 3.3 mm from tip (0.27 in ± 0.13 in) |
Warranty |
1 YEARS |
Additional Info/Comments |
Sheath dimensions 5615-6: 152 mm x 4.76 mm (6.0 in x 0.188 in)
5615-9: 229 mm x 4.76 mm (9.0 in x 0.188 in)
5615-12: 305 mm x 6.35 mm (12.0 in x 0.250 in)
Sheath diameter tolerance ± 0.127 mm (± 0.005 in)
Sheath material Inconel™ 600
Minimum insulation resistance 1000 MΩ at 23 °C
Transition junction temperature range –50 °C to 200 °C
Transition junction dimensions 71 mm x 13 mm dia (2.8 in x 0.5 in)
Maximum immersion length
5615-6: 102 mm (4 in)
5615-9: 178 mm (7 in)
5615-12: 254 mm (10 in)
Response time 9 seconds typical
Self heating (in 0 °C bath) 50 mW/°C
Lead-wire cable type PTFE insulated with PTFE jacket, 22 AWG
Lead-wire length 183 cm (72 in)
Lead-wire temperature range –50 °C to 200 °C |
Calibration Included |
NIST Calibration |
Data Logging |
No |
Interfaces I/O |
Other |
Product Weight |
5.07 LBS |
Product Height |
7.01 IN |
Product Length |
17.99 IN |
Product Width |
15 IN |
Shipping Weight |
5.58 LBS |
ECCN Number |
3A992 |
Country of Origin |
United States |
Shipping Height |
3.94 IN |
Shipping Length |
20.87 IN |
Shipping Width |
12.99 IN |
UPC |
095969402422 |
|
|
|
|