Specifications |
Maximum voltage between any terminal and earth ground |
600 V |
Surge protection |
6 kV peak per IEC 61010–1 600 VCAT III, Pollution Degree 2 |
Fuse for A input |
11 A, 1000 V FAST Fuse (Fluke PN 803293) |
Display |
Digital: 6,000 counts, updates 4 per second |
Bar graph |
33 segments, updates 32 per second |
Operating temperature |
-10°C to +50°C |
Storage temperature |
-40°C to +60°C |
Battery type |
9 volt Alkaline, NEDA 1604A / IEC 6LR61 |
Battery life |
400 hours typical, without backlight |
Accuracy Specifications |
DC millivolts |
Range/resolution |
600.0 mV / 0.1 mV |
Accuracy |
±([% of reading] + [counts]): 0.5% + 2 |
DC volts |
Range/resolution |
6.000 V / 0.001 V |
60.00 V / 0.01 V |
600.00 V / 0.1 V |
Accuracy |
±([% of reading] + [counts]): 0.5% + 2 |
Auto volts |
Range/resolution |
600.0 V / 0.1 V |
Accuracy |
2.0% + 3 (DC, 45 Hz to 500 Hz) |
4.0% + 3 (500 Hz to 1 kHz) |
AC millivolts¹ True RMS |
Range/resolution |
600.0 mV / 0.1 mV |
Accuracy |
1.0% + 3 (DC, 45 Hz to 500 Hz) |
2.0% + 3 (500 Hz to 1 kHz) |
AC volts¹ True RMS |
Range/resolution |
6.000 V / 0.001 V |
60.00 V / 0.01 V |
600.0 V / 0.1 V |
Accuracy |
1.0% + 3 (DC, 45 Hz to 500 Hz) |
2.0% + 3 (500 Hz to 1 kHz) |
Continuity |
Range/resolution |
600 O / 1 O |
Accuracy |
Beeper on < 20 O, off > 250 O detects opens or shorts of |
500 µs or longer. |
Ohms |
Range/resolution |
600.0 O / 0.1 O |
6.000 kO / 0.001 kO |
60.00 kO / 0.01 kO |
600.0 kO / 0.1 kO |
6.000 MO / 0.001 MO |
Accuracy |
0.9% + 1 |
Range/resolution |
40.00 MO / 0.01 MO |
Accuracy |
5% + 2 |
Diode test |
Range/resolution |
2.00 V / 0.001 V |
Accuracy |
0.9% + 2 |
Capacitance |
Range/resolution |
1000 nF / 1 nF |
10.00 µF / 0.01 µF |
100.0 µF / 0.1 µF |
9999 µF / 1 µF |
100 µF to 1000 µF |
Accuracy |
1.9% + 2 |
Range/resolution |
> 1000 µF |
Accuracy |
5% + 20% |
Lo-Z capacitance |
Range |
1 nF to 500 µF |
Accuracy |
10% + 2 typical |
AC amps True RMS (45 Hz to 500 Hz) |
Range/resolution |
6.000 A / 0.001 A |
10.00 A / 0.01 A |
Accuracy |
1.5% + 3 |
20 A continuous overload for 30 seconds max |
DC amps |
Range/resolution |
6.000 A / 0.001 A 10.00 A / 0.01 A |
Accuracy |
1.0% + 3 |
20 A continuous overload for 30 seconds max |
Hz (V or A input)² |
Range/resolution |
99.99 Hz / 0.01 Hz |
999.99 Hz / 0.1 Hz |
9.999 Hz / 0.001 Hz |
50.00 Hz / 0.01 Hz |
Accuracy |
0.1% + 2 |
1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V. |
2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe. |
2. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current. |
2. Temperature Range/Resolution: -40°F to 752°F / 0.2°F. |
Mechanical and General Specifications |
Size |
167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in) |
Weight |
550 g |
Warranty |
3 years |