| Specifications |
| VCHEK1 2 3 |
Range |
6.000 V / 60.00 V / 600.0 V |
| Resolution |
0.001 V / 0.01 V/ 0.1 V |
| Accuracy |
DC, 45 to 500 Hz: 2.0% + 3 |
| 500 Hz to 1 kHz: 4.0% + 3 |
| Diode test4 |
Range |
2.000 V |
| Resolution |
0.001 V |
| Accuracy |
2.0% + 3 |
| Continuity4 |
Accuracy |
Beeper on < 20 O, off > 250 O detects opens or shorts of 500 µs or longer |
| O4 |
Range |
600.0 O / 6.000 kO / 60.00 kO |
| Resolution |
0.1 O / 0.001 kO / 0.01 kO |
| Accuracy |
0.9% + 2 / 0.9% + 1 / 0.9% + 1 |
| Capacitance4 |
Range |
1000 nF / 10.00 µF / 100.0 µF / 9999 µF |
| Resolution |
1 nF / 0.01 µF / 0.1 µF / 1 µF |
| Accuracy |
1.9% + 2 |
| 100 µF - 1000 µF: 1.9% + 2 |
| 1000 µF: 5% + 20 |
| 1. All VChek voltage ranges are specified from 60 counts to 100% of range. Because inputs below 60 counts are not specified, it is possible and normal for this and other true-rms meters to display non-zero readings when the test leads are disconnected from a circuit or are shorted together. |
| 2. Crest factor of = 3 at 4000 counts, decreasing linearly to 1.5 at full scale. |
| 3. Minimum measureable input in VCHEK autorange is 3 VDC. For measurements below 3 VDC, push Range button twice to get to 6 VDC manual range. |
| 4. After measuring voltage, a wait time of 1 minute is required to maintain accuracy of ohms, capacitance, diode test, and continuity. |
| Specifications |
| Maximum voltage between any terminal and earth ground |
600 V |
| Display |
3 3/4-digits, 6000 counts, updates 4/sec |
| Operating temperature |
-10°C to 50°C (14°F to 122°F) |
| Storage temperature |
-40°C to 60°C (-22°F to 140°F) |
| Temperature coefficient |
0.1 x (specified accuracy) / °C (< 18°C or > 28°C) |
| Operating altitude |
2,000 m |
| Storage altitude |
10,000 m |
| Relative humidity |
95% to 30°C |
| 75% to 40°C |
| 45% to 50°C |
| Battery type |
9 Volt Alkaline, ANSI 1604A / IEC 6F22 |
| Battery life |
Alkaline: 300 hours typical, without backlight |
| Shock |
1 Meter drop per IEC 61010–1–2001 |
| Vibration |
Per MIL-PRF-28800 for Class 2 instrument |
| Size (H x W x L) |
167.1 x 85.1 x 46.0 mm (6.58 x 3.35 x 1.81 in) |
| Weight |
13.0 oz (404 g) |
| Safety |
Complies with ANSI / ISA 82.02.01 (61010–1) 2004, CAN / CSA-C22.2 No 61010-1-04, UL 61010–1 (2004) and IEC / EN 61010–1 2nd Edition for measurement Category IV, 600 V, Pollution Degree 2, EMC EN61326–1 |
| EMI regulations |
Complies with FCC Part 15, Class B |
| Specifications |
| VCHEK |
Input impedance (nominal) |
~3 kO < 300 pF |
| VCHEK |
Common mode rejection ratio |
> 60 dB at DC, 50 or 60 Hz |
| (1 kO unbalanced) |
| O |
Open circuit test voltage |
< 2.7 VDC |
| Full scale voltage |
< 0.7 VDC |
| Diode test |
Open circuit test voltage |
2.7 VDC |
| Full scale voltage |
2.000 VDC |
| O |
Short circuit current |
< 350 µA |
| Diode test |
Short circuit current |
< 1.0 mA |