|
|
Fluke MDA-550-III
Catalog #: 5282560
Motor Drive Analyzer 550, 4-channel color, PRO
- Overview
- Specifications
- Cases
- Software
- Probes
- Clamp Meters
- Accessories
Product Highlights
- Motor Drive Analyzer, 4 Channel, 500 MHz with motor shaft and harmonics
- Guided testing with graphical step-by-step voltage and current connection diagrams makes setup and connection to variable frequency drives easier than ever
- Preset measurement profiles collect data based on the chosen test procedure and reduce the need for complex configuration
- Built-in report writing capabilities make it easy to produce professional as-found and as-left motor-drive troubleshooting reports
Each Unit Includes
- (1) BP 291 li-ion battery pack
- (1) BC190 charger/power adapter
- (3) VPS 100:1 high voltage probes with alligator clips
- (1) VPS410-II-R 10:1 500MHz voltage probe
- (3) i400s ac current clamp
- (1) C1740 carrying case
- (1) 2 GB USB drive with manuals and FlukeView™ 2 software
- (1) SVS-500 shaft voltage set (3x brush, probe holder, two-piece extension rod and magnetic base)
Measurement Function |
DC voltage (V dc) |
Maximum voltage with 10:1 or 100:1 probe |
1000 V |
Maximum resolution with 10:1 or 100:1 probe |
1 mV |
Full scale reading |
999 counts |
Accuracy at 4 s to 10 us/div |
±(3 % + 6 counts) |
AC voltage (V ac) |
Maximum voltage with 10:1 or 100:1 probe |
1000 V |
Maximum resolution with 10:1 or 100:1 probe |
1 mV |
Full scale reading |
999 counts |
50 Hz |
±(3 % + 10 counts) - 0.6 % |
60 Hz |
±(3 % + 10 counts) - 0.4 % |
60 Hz to 20 kHz |
±(4 % + 15 counts) |
20 kHz to 1 MHz |
±(6 % + 20 counts) |
1 MHz to 25 MHz |
±(10 % + 20 counts) |
True-rms voltage (V ac+dc) |
Maximum voltage with 10:1 or 100:1 probe |
1000 V |
Maximum resolution with 10:1 or 100:1 probe |
1 mV |
Full scale reading |
1100 counts |
DC to 60 Hz |
±(3 % + 10 counts) |
60 Hz to 20 kHz |
±(4 % + 15 counts) |
20 kHz to 1 MHz |
±(6 % + 20 counts) |
1 MHz to 25 MHz |
±(10 % + 20 counts) |
PWM voltage (V pwm) |
Purpose |
To measure on pulse width modulated signals, like motor drive inverter outputs |
Principle |
Readings show the effective voltage based on the average value of samples over a whole number of periods of the fundamental frequency |
Accuracy |
As Vac+dc for sinewave signals |
Peak voltage (V peak) |
Modes |
Max peak, min peak, or pk-to-pk |
Maximum voltage with 10:1 or 100:1 probe |
1000 V |
Maximum resolution with 10:1 or 100:1 probe |
10 mV |
Accuracy |
Max peak, min peak |
±0.2 division |
Pk-to-pk |
±0.4 division |
Full scale reading |
800 counts |
General Specification |
Current (AMP) with current clamp |
Ranges |
Same as V ac, Vac+dc or V peak |
Scale Factors |
0.1 mV/A, 1 mV/A, 10 mV/A, 20 mV/A, 50mV/A, 100 mV/A, 200 mV/A, 400 mV/A |
Accuracy |
Same as Vac, Vac+dc or V peak (add current clamp accuracy) |
Frequency (Hz) |
Range |
1.000 Hz to 500 MHz |
Full scale reading |
999 counts |
Accuracy |
±(0.5 % + 2 counts) |
Voltage/Herz ratio (V/Hz) |
Purpose |
To show the measured V PWM value (see V PWM) divided by the fundamental frequency on variable ac motor speed drives |
Accuracy |
% Vrms + % Hz |
Voltage unbalance drive input |
Purpose |
To show the highest percentage difference of one of the phase vs average of the 3 true-rms voltages |
Accuracy |
Indicative percentage based on Vac+dc values |
Voltage unbalance drive output and motor input |
Purpose |
To show the highest percentage difference of one of the phase vs average of the 3 PWM voltages |
Accuracy |
Indicative percentage based on V PWM values |
Current unbalance drive input |
Purpose |
To show the highest percentage difference of one of the phase vs average of the 3 AC current values |
Accuracy |
Indicative percentage based on Aac+dc values |
Current unbalance drive output and motor input |
Purpose |
To show the highest percentage difference of one of the phase vs average of the 3 AC current values |
Accuracy |
Indicative percentage based on A ac values |
Rise and fall time |
Readings |
Voltage difference (dV), time difference (dt), voltage vs time difference (dV/dt), overshoot |
Accuracy |
As oscilloscope accuracy |
Harmonics and spectrum |
Harmonics |
DC to 51st |
Spectrum ranges |
1…9 kHz, 9-150 kHz (20 MHz filter on), up to 500 MHz (voltage modulation) |
Shaft voltage |
Events / second |
Indicative percentage based on rise and fall time (Impulse discharges) measurements |
Report data capture |
Number of screens |
Typical 50 screens can be saved in reports (depends on compression ratio) |
Transfer to PC |
Using 2 GB USB stick or mini-USB to USB cable and FlukeView™ 2 for ScopeMeter™ test tool |
Probe settings |
Voltage probe |
1:1, 10:1, 100:1, 1000:1, 20:1, 200:1 |
Current clamp |
0.1 mV/A, 1 mV/A, 10 mV/A, 20 mV/A, 50 mV/A, 100 mV/A, 200 mV/A, 400 mV/A |
Shaft voltage probe |
1:1, 10:1, 100:1 |
|
Cases
Software
Probes
Product |
Price |
|
Fluke VPS410-II-R
Catalog #: 4276928
Industrial Voltage Probe Set 500MHZ 10:1 Red
|
$262.24
|
Clamp Meters
Product |
Price |
|
Fluke I400S
Catalog #: 2277202
Current Probe
|
$364.24
|
Accessories
Product |
Price |
|
Fluke BP291
Catalog #: 3894688
Li-Ion Double Capacity Battery Pack
|
$463.24
|
|
Fluke SB-500
Catalog #: 5011046
Replacement brushes for SVS-500 and MDA-500
|
$389.24
|
|
Fluke SVS-500
Catalog #: 5011031
Shaft Voltage Set and Magnetic Base
|
$514.24
|
|
|
|