Fluke 1777/BASIC
Catalog #: 5272819
Three-Phase Power Quality Analyzer with Hard Carrying Case (No I17XX-FLEX1500 24 Probe)
- Overview
- Specifications
- Summary
- Accessories
Product Highlights
- Three-phase power quality analyzer
- Does not Includes I17XX-FLEX1500 24 Probe and
- Includes Hard Carrying Case
- Automatically measure power and power quality parameters
- Critical power quality data captured as soon as users begin sessions, without extensive setup or selections
- Intuitive user interface streamlined to makes it easy to navigate between measurement parameters like V/A/Hz, power, dips and swells, harmonics, or power quality health, with single push of button
- High-speed voltage transient captures damaging high-speed transients so users can mitigate their effects before equipment fails
- Analysis and reporting comes standard with Fluke Energy Analyze Plus software, giving users ability to create customized reports, or leverage built-in one-click reporting to industry standards, like EN 50160, IEEE 519 and GOST 33073
- Energy studies: Get detailed power and energy consumption profiles during energy audits and pinpoint savings opportunities
- Basic harmonics study: Discover source of distortion in user installation, to filter loads or move them to separate circuits
- Advanced harmonics study: If distorting loads are causing problems during installation, users need comprehensive data to identify source in order to create solutions
- Basic industrial PQ troubleshooting: When troubleshooting in field, graphical data enables users to trace source of problems at hand
- Advanced PQ troubleshooting: Complex installations often require deeper dive into measurement data; multiple loads may be interacting randomly to cause single problem
- Inrush: Discover peak current from load switching
- Flicker: Measure effects of disturbing switching equipment
- Transients: Capture high speed voltage waveform caused by switching or network disturbances
- Mains signaling: Monitor signals on the network that are used for network wide equipment control
- Event waveform capture: Visualization of dips and swells to identify cause of the events
- Interfaces:
- USB
- Ethernet
- Wi-Fi
- Bluetooth
- Wireless download
- Safety: 600 V/CAT IV; 1000 V/CAT III; Power from measurement line
Applications
- Energy surveys and load testing
- Harmonic surveys
- Nuisance circuit breaker tripping
- Power utility power quality surveys
- Discovery of equipment failures caused by transients
Each Unit Includes
- 1 - 1777 Three-Phase Power Quality Analyzer
- 1 - Flat Cable, Voltage Test Lead, 3-PHASE+N
- 4 - AC285, Black Alligator Clips
- 1 - AC285, Green Alligator Clip
- 1 - Black USB-C Cable, 1m
- 1 - Line Cord
- 1 - Test Lead Set, Nonstack/Stack, 0.18m
- 1 - Green Test Lead
- 1 - Magnet Probe, 3 Red / 1 Black Magnet Probes for 4mm Banana
- 1 - Hanger Kit
- 1 - WIFI/BLE Module
- 1 - Colored Cable Marker Set for Voltage and Current
- 1 - Wall Outlet Adapter
- 1 - Certificate of Calibration
- 1 - Hard Carrying Case
Voltage inputs |
Number of inputs |
4 inputs, 3 phases and neutral referenced to PE (5 connectors) |
Measurement category |
1000 V CAT III / 600 V CAT IV |
Maximum input voltage |
1000 V rms / 1000 V dc (1700 Vpk) Nominal voltage range Wye and single phase: variable (50 V - 1000 V)
Delta: Variable (100 V - 1000 V)
IEC 61000-4-30 Class A compliance for the nominal voltages (Vdin) 100 V - 690 V |
Input impedance |
10 MΩ between P-P and P-N, 5 MΩ between P-PE and N-PE |
Bandwidth |
DC to 30 kHz for PQ measurements, excluding transients |
Resolution |
24-bit synchronous sampling |
Sampling frequency |
80 kS/s at 50/60 Hz |
Scaling |
1:1, variable for use of potential transformers |
Voltage transients |
Measurement range |
±8 kV |
Sampling rate |
1775: 1 MS/s |
1777: 1 MS/s, 20 MS/s |
Bandwidth |
DC to 1 MHz |
Trigger |
Adjustable trigger level. Triggers on high-frequency components > 1.5 kHz |
Resolution |
14-bit synchronous sampling |
Current inputs |
Number of inputs |
4 inputs 3 phases and Neutral, range selected automatically to attached sensor |
Range |
AC |
1 A to 1500 A with i17XX-FLEX1500 12
1 A to 1500 A with i17XX-FLEX1500 24
3 A to 3000 A with i17XX-FLEX3000 24
6 A to 6000 A with i17XX-FLEX6000 36
40 mA to 40 A with clamp i40s-EL
4 A to 400 A with clamp i400s-EL |
DC |
20 A to 2000 A with 80i-2010-EL clamp |
Bandwidth |
DC to 30 kHz |
Resolution |
24-bit synchronous sampling |
Sampling frequency |
80 kS/s at 50/60 Hz |
Scaling |
1:1, variable |
Input voltage |
Clamp: 50 mV / 500 mV rms; CF 2.8
Rogowski Coil: 15 mV / 150 mV rms at 50 Hz, 18 mV / 180 mV rms at 60 Hz
CF 4 all at nominal probe range |
Input impedance |
11 kΩ |
Standard compliance |
Power |
IEEE 1459 |
Harmonics |
IEC 61000-4-7: Class 1
IEEE 519 (short time and very short time harmonics) |
Flicker |
IEC 61000-4-15 Class F1 |
Power quality |
IEC 61000-4-30 Class A, IEC 62586 PQI-A-PI |
Power quality compliance |
EN 50160 + GOST + NEQUAL + NETCODE + FOL |
Interfaces |
Ethernet |
1 Gbit/s 1000BASE-T |
USB type A |
USB 2.0 high speed for USB flash drives to transfer measurement data, firmware updates and license installation. Max. supply current: 500 mA |
USB-C |
USB 2.0 high speed for data download to PC and calibration (requires USB type A to USB-C or USB-C to USB-C cable)
Auxiliary power supply for the Analyzer (requires USB C power adapter PD 2.0 or higher with 9 V 1.8 A support)
USB 3.0 super-speed for USB-C flash drives to transfer measurement data, firmware updates and license installation. Max. supply current: 900 mA |
WiFi/BLE module1 |
802.11 ac 2.4 GHz / 5 GHz, support for concurrent access point and client mode
Bluetooth 5.0/BLE
Antenna: Internal and external2 |
LTE/4G module3 |
LTE-A Cat 12
Worldwide LTE-A and UMTS/HSPA+ coverage
Antenna: External2 |
GPS |
MCX connector to attach a GNSS antenna for GPS/GLONASS2 |
- Not in 177X/BASIC versions
- Requires 5m extension cable, Fluke p/n 5263915
- Availability and supported providers vary by country. Check with your local Fluke representative
|
Power Measurement/Power Quality Analyzer Template |
Type (Power Quality) |
3 Phase |
Maximum Current AC |
6000 A |
Maximum Current DC |
2000 A |
True Power / Work ( W) |
Yes |
Apparent Power (VA) |
Yes |
Reactive Power (VAR) |
Yes |
Current Input Channels |
4 |
Voltage Input Channels |
4 |
Measurement Frequency (Power Quality) |
50 Hz, 60 Hz |
Display (Power Quality) |
Digital |
Transient Capture |
Yes |
Displays Waveform |
Yes |
Energy |
Yes |
Phasor Diagrams |
No |
Maximum Harmonics Range |
50 |
Class A Compliant |
Yes |
Crest Factor |
No |
CAT Rating |
IV |
CAT Voltage Rating (V) |
600V |
GPS Location |
Yes |
Warranty |
2 YEARS |
Interfaces I/O |
LAN / Ethernet, Wifi, USB, USB-C, WWAN |
Storage |
Internal Memory, Micro SD |
IP Rating |
IP50 |
Product Weight |
4.6 LBS |
Product Height |
2.4 IN |
Product Length |
11 IN |
Product Width |
7.5 IN |
Shipping Weight |
5.29 LBS |
Data Logging |
Yes |
Battery Type |
Li-ion |
|
Accessories
Product |
Price |
|
Fluke 177X LI-ION BATTERY
Catalog #: 5272862
Li-Ion Battery for 177X Series Units, 3.56V, 4000 mAh
|
$142.24
|
|
Fluke C1777 HARD CASE
Catalog #: 5307460
IP67 Rated Hard Carrying Case with Wheels for 1777 Units
|
$1,012.24
|
|
Fluke C177X
Catalog #: 5307472
Soft Carrying Case for 177X Series and NORMA 6000 Series Units (Black)
|
$416.24
|
|
Fluke I17XX-FLEX1500 24
Catalog #: 5171005
iFlex Flexible Current Probe for 17XX Series Units, 1500A, 24 in.
|
$290.24
|
|
|
|