Fluke 190-202-III-S
Catalog #: 5282442
2-Channel Color ScopeMeter with DMM/External Input and SCC-293 Kit, 200 MHz

  • Overview
  • Specifications
  • Summary
  • Probes
  • Accessories

Product Highlights

  • CAT III 1000 V/CAT IV 600 V rated portable oscilloscopes
  • Connect-and-View™ triggering automatically displays waveforms without having to adjust amplitude, timebase and trigger settings
  • Large, bright color display for easy in-the-field viewing and both USB and Wi-Fi data download options for analyzing data with FlukeView® software

Oscilloscope modes

  • Number of channels: Two (2)
  • Bandwidth: 200 MHz
  • Rise time: 1.7 ns
  • Number of scope inputs: 2 input channels plus external trigger
  • Channel architecture: All inputs fully insulated from each other and from ground; Inputs may be activated in any combination
  • Input coupling: AC or DC, with ground level indicator
  • Input sensitivity: With 10:1 probe, 20 mV to 1000 V/div; With 100:1 probe, 200 mV to 10 kV/div; Direct (1:1), 2 mV to 100 V/div
  • Bandwidth limiter: 20 MHz and 10 kHz
  • Polarity: Normal, Inverted, Variable
  • Vertical resolution: 8 bit
  • Accuracy at 4 s to 10 μs/div: 5 mV/div to 100 V/div, ±(1.5 % + 6 counts); 2 mV/div, ±(1.5 % + 10 counts)
  • Input impedance: 1 MΩ (± 1 %) // 15 pF (± 2.25 pF)
  • Horizontal
    • Maximum realtime sample rate (sampled simultaneously): 2.5 GS/s (each channel)
    • Record length: Up to 10,000 samples per channel
    • Time base range: 2 ns/div to 4 s/div; Time base in a 1-2-4-sequence; Slower time/division settings using ScopeRecord™ Roll mode
    • Maximum record length: 10,000 samples per channel in scope mode; 30,000 points per channel in ScopeRecord™ Roll mode
    • Timing accuracy: ± (0.01 % of reading + 1 pixel)
    • Glitch capture: 8 ns (10 μs/div to 2 min/div)
  • Display and acquisition
    • Display: 133 mm x 90 mm (5.3 in x 3.5 in) full-color high brightness LCD
    • Display modes: Any combination of channels; average on/off; replay
    • Visible screen width: 12 divisions horizontally in scope mode
    • Digital persistence modes: Off, short, medium, long, infinite and envelope mode
    • Waveform mathematics: One (190-xx2) or two (190-x04) mathematical operations on 2 input channels (A and B, C and D): add, subtract, multiply; X-Y-mode; Frequency Spectrum using FFT
    • Acquisition modes: Normal, Averaged, Auto, Single Shot, ScopeRecord™ roll, glitch capture, waveform compare with automatic "Pass/Fail testing"; Replay
  • Trigger and delay
    • Source: Input A, B or External (via meter input)

Each Unit Includes

  • 1 - 190-202-III 2-Channel Color ScopeMeter with DMM/External Input, 200 MHz
  • 1 - BC190/830 Power Adapter
  • 1 - Power Cord Set
  • 1 - BP290 Li-ion Battery Pack
  • 1 - TL175 Test Lead Set
  • 2 - VPS410-II Probes
  • 1 - Hanging Strap
  • 1 - USB-Cable
  • 1 - CXT293 Carrying Case
  • 1 - DWA-131 WiFi Dongle
  • 1 - FlukeView Activation Instructions
  • 1 - User Manual

 

Oscilloscope Modes
  190-062 190-102 190-202 190-502 190-104 190-204 190-504
Vertical deflection
Number of channels 2 2 2 2 4 4 4
Bandwidth 60 MHz 100 MHz 200 MHz 500 MHz 100 MHz 200 MHz 500 MHz
Rise time 5.8 ns 3.5 ns 1.7 ns 0.7 ns 3.5 ns 1.7 ns 0.7 ns
Number of scope inputs 2 input channels plus external trigger 4 input channels
Channel architecture All inputs fully insulated from each other and from ground. Inputs may be activated in any combination.
Input coupling AC or DC, with ground level indicator
Input sensitivity With 10:1  probe, 20 mV  to 1000 V/div
With 100:1  probe, 200 mV to 10 kV/div
Direct (1:1),  2 mV  to 100 V/div
Bandwidth limiter 20 MHz and 10  kHz
Polarity Normal,  Inverted, Variable
Input voltage CAT III 1000 V/CAT IV 600 V rated, see General specifications for further details
Vertical resolution 8 bit
Accuracy at 4 s to 10 μs/div 5 mV/div to 100 V/div, ±(1.5 % + 6 counts)
2 mV/div, ±(1.5  % + 10 counts)
Input impedance 1 MΩ (± 1 %) //  15  pF (± 2.25  pF)
Horizontal
Maximum real- time sample rate (sampled simultaneously) 625 MS/s
(each channel)
1.25 GS/s (each channel) 2.5 GS/s (each channel) 5 GS/s (single channel) or
2.5 GS/s (dual channel)
1.25 GS/s (each channel) 2.5 GS/s (2ch)
1.25 GS/s (4ch)
5 GS/s (single ch) or 2.5 GS/s (2ch) or 1.25 GS/s (4ch)
Record length Up to 10,000 samples per  channel
Time base range 10 ns/div
to 4 s/div
5 ns/div
to 4 s/div
2 ns/div
to 4 s/div
1 ns/div
to 4 s/div
5 ns/div
to 4 s/div
2 ns/div
to 4 s/div
1 ns/div
to 4 s/div
Time base in a 1-2-4-sequence
Slower time/division settings using ScopeRecord™ Roll mode (see ‘Recorder mode’)
Maximum record length 10,000 samples per channel in scope mode
30,000 points per channel in ScopeRecord™ Roll mode (see ‘Recorder mode’)
Timing accuracy ± (0.01 % of reading + 1  pixel)
Glitch capture 8 ns (10  µs/div to 2 min/div)
Display and acquisition
Display 133 mm x 90 mm (5.3 in x 3.5 in) full-color high brightness LCD
Display modes Any combination of channels; average on/off; replay.
Visible screen width 12  divisions horizontally in scope mode
Digital persistence modes Off, short, medium, long, infinite and envelope mode
Waveform mathematics One (190-xx2) or two (190-x04) mathematical operations on 2 input channels (A and B, C and D): add, subtract, multiply; X-Y-mode; Frequency Spectrum using FFT
Acquisition modes Normal, Averaged, Auto, Single Shot, ScopeRecord™ roll, glitch capture, waveform compare with automatic “Pass/Fail testing”; Replay
Trigger and delay
Source Input A, B or External (via meter input) Input A, B, C or  D
Modes Automatic, Edge, Pulse Width, N-Cycle, External (190-xx2)
Connect-and- View™ Advanced automatic triggering that recognizes signal patterns, automatically sets up and continuously adjusts  triggering, time base and amplitude. Automatically displays stable waveforms of complex and dynamic signals like motor drive and control signals. Can be switched off if preferred.
Pulse width triggering (on channel A) Pulse width qualified by time
Allows for triggering <t, >t, =t, ≠ t, where t is selectable in minimum steps of 0.01 div or 50 ns
Time delay 1 full screen of pre-trigger view or up to 100 screens (=1,200 divisions) of post-trigger delay
Dual slope triggering Triggers on both rising and falling edges alike
N-cycle triggering Triggers on N-th occurrence of a trigger event; N to be set in the range 2 to 99
Automatic capture of 100 screens
When in oscilloscope mode, the instrument ALWAYS memorizes the last 100 screens—no specific user setup required. When an anomaly is seen, the REPLAY button can be pressed to review the full sequence of screen events over and over. Instrument can be set up for triggering on glitches or intermittent anomalies and will operate in “baby-sit” mode capturing 100 specified events.
Replay Manual or continuous replay. Displays the captured 100 screens as a “live” animation, or under manual control. Each screen has date and time-stamp.
Replay storage Ten sets of 100 screens each can be saved internally for later recall and analysis. Direct storage of additional sets on external flash memory drive through USB host port.
FFT—frequency spectrum analysis
Shows frequency content of oscilloscope waveform using Fast Fourier Transform
Window Automatic, Hamming, Hanning or None
Automatic window Digitally re-samples acquired waveform to get optimum frequency resolution in FFT resultant.
Vertical scale Linear/Logarithmic (in volts or amps)
Frequency axis Frequency range automatically set as a function of timebase range of oscilloscope
Waveform compare and pass/fail testing
Waveform compare Provides storage and display of a reference waveform for visual comparison with newly acquired waveforms. Reference is derived from an acquired waveform and can be modified in the oscilloscope.
Pass/Fail testing In waveform compare mode, the oscilloscope can be set up to store only matching (“Pass”) or only non-matching (“Fail”) acquired waveforms in the replay memory bank for further analysis.
Automatic scope measurements
V dc, V ac rms, V ac+dc, Vpeak max, Vpeak min, Vpeak to peak, A ac, A dc, A ac+dc, frequency (in Hz), rise time (using cursors), fall time (using cursors), Power Factor (PF), Watts, VA, VA  reactive, phase (between 2 inputs A&B or C&D), pulse width (pos./neg.), duty cycle (pos./ neg.), temperature °C, temperature °F (not for Japan), dBV, dBm into 50 Ω and 600 Ω, VPWM ac and VPWM(ac+dc) for measurement on pulse width modulated motor drives and frequency inverters, V/Hz ratio;
Advanced power and motor drive functions V/Hz ratio, Power Factor (PF), Watts, VA, VA reactive, V-PWM (ac) and V-PWM (ac+dc) for measure- ment on pulsewidth modulated motordrives and frequency inverters
Cursor measurements
Source On any input waveform or on mathematical resultant waveform (excl. X-Y-mode)
Dual horizontal lines Voltage at cursor 1 and at cursor 2, voltage between cursors
Dual vertical lines Time between cursors, 1/T between cursors (in Hz), voltage between markers, risetime with markers, falltime with markers; Vrms between cursors, Watts between cursors.
Single vertical line Min-Max and Average voltage at cursor position; frequency and rms-value of individual frequency component in the FFT Resultant
Advanced functions mA*s (current-over-time, between cursors); V*s (voltage-over-time, between cursors); W*s (energy, between cursors)
ZOOM Ranges from full record overview to zoom in up to sample level, at any record length.

 

Meter modes
  190-062 190-102 190-202 190-502 190-104 190-204 190-504
Meter inputs Via 4 mm banana inputs, fully isolated from scope inputs and scope ground Via BNC scope inputs
Number of readings One at a time via DMM input Up to 4 automatic scope measurements simultaneously
Maximum resolution 5,000 counts ± 999 counts
(frequency: 9999 counts)
Input impedance 1 MΩ (± 1 %) // 14 pF (± 1.5 pF) 1 MΩ (± 1 %) // 15 pF (± 2.25 pF)
Advanced meter functions Auto/manual ranging, relative measurements (Zero reference), TrendPlot™ recording
  The specified accuracy is valid over the temperature range 18 °C to 28 °C Add 10 % of specified accuracy for each degree C below 18 °C or above 28 °C
Voltage
V dc accuracy ± (0.5 % + 6 counts) ± (1.5 % + 6 counts)
V ac true rms accuracy
15 Hz to 60 Hz ± (1 % + 10 counts) ± (1.5 % + 10 counts)
60 Hz to 1 kHz ± (2.5 % + 15 counts)
60 Hz to 20 kHz ± (2.5 % + 15 counts)
V ac+dc true rms accuracy
15 Hz to 60 Hz ± (1 % + 10 counts) ± (1.5 % + 10 counts)
60 Hz to 1 kHz ± (2.5% + 15 counts)
60 Hz to 20 kHz ± (2.5 % + 15 counts)
Voltmeter ranges 500 mV, 5 V, 50 V, 500 V, 1,100 V  
Resistance
Ranges 500 Ω, 5 kΩ, 50 kΩ, 500 kΩ, 5 MΩ, 30 MΩ
Accuracy ± (0.6 % + 6 counts)
Other meter functions
Continuity Beeper on < 50 Ω (± 30 Ω)
Diode test Up to 2.8 V
Current (A) A dc, A ac, A ac+dc using an optional current clamp or shunt Scaling factors: 0.1 mV/A, 1 mV/A to 100 V/A and 400 mV/A
Temperature With optional accessories. Scale factors 1mV/°C or 1mV/°F

 

Recorder mode
  190-062 190-102 190-202 190-502 190-104 190-204 190-504
ScopeRecord™ Roll Mode
Dual or multiple input waveform storage mode, using deep memory
Source and display Input A, Input B,  Dual
All channels sampled simultaneously
Any combination of inputs, up to 4 channels.
All channels sampled simultaneously
Memory depth 30,000 data points per channel, each holding min/max pair of information
Min/max values Min/max values are created at samples that are measured at high sample rate ensuring capture and display of glitches.
Recording modes Single sweep, continuous roll; Start-on-Trigger (through external); Stop-on-Trigger (through external) Single sweep, continuous roll; Start-on-Trigger (through any channel); Stop-on-Trigger (through any channel)
Stop-on-trigger ScopeRecord mode can be stopped by an individual trigger event, or by an interruption
of a repetitive trigger signal, through any input channel (through External on 190-XX2 Series)
Horizontal scale Time from start, time of  day
Zoom Ranges from full record overview to zoom in up to sample level
Memory Two multiple input ScopeRecord waveforms can be saved internally for later recall and analysis.
ScopeRecord™ Roll mode sample rate and recording timespan
Time base range 4 ms/div to 2 min/div
Recorded timespan 4.8 sec to 40 hr
Time/division in ‘view all’ mode 0.4 s/div to 4 h/div
Glitch capture 8 ns
Sample rate 125 MS/s
Resolution 160 μsec ~ 4.8 sec
Trendplot™ Recording
Multiple channel electronic paperless recorder. Graphically plots, displays and stores results of up to four automatic scope measurements or a DMM-reading over time.
Source and display Any combination of scope measurements, made on any of the input channels, or DMM reading (2-channel instruments)
Memory depth 19,200 points (sets) per recording. Each recorded sample point contains a minimum, a maximum and an average value, plus a date- and time-stamp.
Ranges Normal view: 5 s/div to 30 min/div; In view-all mode: 5 min/div to 48 hr/div (overview of total record)
Recorded time span Up to 22 days, with a resolution of 102 seconds; up to 5.5 days for 4 readings.
Recording mode Continuous recording, starting at 5 s/div with automatic time-scale compression
Measurement speed Three automatic measurements per second or more
Horizontal scale Time from start, time of day
Zoom Up to 64x zoom-out for full record overview, up to 10x zoom-in for maximum detail
Memory Two multiple input TrendPlot records can be saved internally for later recall and analysis.
Cursor measurements—all recorder modes
Source Any waveform trace in any waveform display mode (Scope, ScopeRecord or TrendPlot)
Dual vertical lines Cursors may be used to identify Min, Max or Average value of any datapoint in a record, with time between cursors, time from start or absolute time.

 

General specifications
Input voltage range
Rated maximum floating voltage CAT III 1000 V / CAT IV 600 V (maximum voltage between any contact and earth-ground voltage level)
Probe input voltage VPS410-II CAT III 1000 V / CAT IV 600 V (Maximum voltage between standard 10:1 probe tip and reference lead)
Probe input voltage VPS421 CAT III 1000V / CAT IV 600V (Maximum voltage between probe tip or reference lead to GND, 2000V max between probe tip and reference lead)
Maximum BNC input voltage CAT IV 300 V (maximum voltage on BNC input directly)
Maximum volt- age on meter input CAT III 1000 V / CAT IV 600 V
(safety designed banana input connectors)
Memory save and recall
Memory loca- tions (internal) 30 waveform memories plus 10 recording memories plus 9 screen copy memories
30 waveform memories Each memory can contain up to 2 or 4 waveforms plus corresponding setups.
10 recording memories Each may contain: a 100 Screen Replay sequence, or a ScopeRecord Roll-mode recording (2 or 4 traces), or a TrendPlot recording of up to 4 measurements
External data storage On PC, using FlukeView™-2 Software, or direct storage on external flash memory drive (maximum 32 GB) through USB host port
Screencopies On PC, using FlukeView™-2  Software, or internally (in instrument) which can be copied on to external flash memory drive as .BMP-file, through USB host port
Volatility Saving is done in non-volatile Flash-ROM and all data is secured, independent of battery or power status.
Real-time clock Provides date and time stamp information for ScopeRecord, for 100 Screen Replay sequences and for TrendPlot recordings.
Case
Design Rugged, shock-proof with integrated protective holster. Handstrap and hangstrap included as standard.
Kensington lock supported to lock down instrument when left unattended.
Drip and dust proof IP 51  according to IEC60529
Shock and vibration Shock 30 g, vibration (sinusoidal) 3 g / 0.03 g2/Hz (Random), according to MIL-PRF-28800F Class 2
Display size 133 mm x 90 mm (5.3 in x 3.5 in) LCD
Resolution 1120  pixels x 765 pixels
Brightness User-adjustable, up to 300  cd/m2
Mechanical data
Size 265 mm x 192 mm x 70 mm (10.5 in x 7.6 in x 2.8 in)
Weight (including battery) 2.1 kg (4.6 lb) 2.2 kg (4.8 lb)
Power
Line power Universal mains adapter/battery charger BC190/830 included, with detachable 2-wire power cords 100 Vac to 240 Vac, ±10 %, 50-60 Hz
Battery power Re-chargeable Li-Ion battery (included). Battery swappable through easily accessible battery door at the rear of the instrument
Battery type (incl.) and capacity [+opt. battery] BP290: 10.8V, 2500 mAh
[BP291 (5000 mAh) optional]
BP291: 10.8V, 5000 mAh
Battery charge indicator Battery has built-in status indicator for use with external charger, next to battery status indicator on instrument screen.
Battery operat- ing time (with backlight low) Up to 3.5 using BP290  (included), up to 7 hours using BP291 (optional) Up to 7 hours using BP291 (included)
Battery charging time 2½ hours using BP290; 5 hours using BP291 Five hours for BP291
Battery power saving functions Auto ‘power down’ with adjustable power down time. Automatic ‘display off’ with adjustable power down time.
On-screen battery power indicator
Safety
Compliance EN61010-1,  Pollution Degree 2;
IEC 61010-2-030: CAT IV 600 V / CAT III 1000 V
Environmental
Operating temperature Battery discharging: 0 °C to 40 °C (32 °F to 104 °F)
Battery charging: 0 °C to 40 °C (32 °F to 104 °F)
Storage temperature -20  °C to 60 °C (-4 °F to 140  °F)
Humidity 0 °C to 10 °C (32 °F to 50 °F): noncondensing
10 °C to 30 °C (50 °F to 86 °F): 95 % (±5 %)
30 °C to 40 °C (86 °F to 104 °F): 75 % (±5 %)
40 °C to 50 °C (104 °F to 122 °F): 45 % (±5 %)
Maximum operating altitude CAT IV 600 V, CAT III 1000 V: up to 2000 m (6 600 feet)
CAT IV 300 V, CAT III 600 V, CAT II 1000 V: up to 4000 m (13 000 feet)
Maximum storage altitude 12  km (40,000 ft)
Electro-Magnetic Compatibility (EMC) IEC 61326-1: Industrial;
CISPR 11:  Group 1,  Class A;
Korea (KCC): Class A Equipment (Industrial Broadcasting and Communication Equipment);
USA (FCC): 47 CFR 15 subpart C.
Interfaces Two USB-ports provided. Ports are fully insulated from instrument’s floating measurement circuitry.
USB-host port directly connects to external flash memory drive (up to 32 GB) for storage of waveform data, measurement results, instrument settings and screen copies. Alternatively, this USB-A port may be used to connect a WiFi Adapter for wireless PC connectivity. A mini-USB-B is provided which allows for interconnection to PC for remote control and data transfer under PC-control using FlukeView-2.
Probe calibration output Dedicated probe-cal output with reference contact provided, fully insulated from any measurement input channel.
Generator Output: 1.225 Vpp / 500 Hz square wave
Warranty 3 years on main instrument, 1 year on battery and accessories
Included accessories
Battery charger/ mains adapter BC190/830
Li-Ion battery pack BP290 (10.8V, 2500 mAh) BP291 (10.8V, 5000 mAh)
Voltage probe sets. Each set includes ground lead, hook clip; ground spring and probe tip insulation sleeve with VPS410-II-x. 2 pcs VPS421-x, ruggedized industrial-grade probes, 100:1, 150MHz with shrouded 4mm banana tip and large jaw alligator clips (one red, one blue) 2 pcs VPS410-II-x, 10:1 voltage probes, 500 MHz, (one red, one blue) 4 pcs VPS421-x, ruggedized probes, 100:1, 150 MHz, (red, blue, grey, green) 4 pcs VPS410-II-x, 10:1 voltage probes, 500 MHz, (one red, one grey, one blue, one green)
Test leads TL175 (one red, one black) with test pins
Other Li-Ion battery (BP290 or BP291,  see above), Battery charger (BC190) with universal power cord set, Hangstrap, Handstrap (user selectable for left- or right hand use), download information for user manual and FlukeView®-2 demo package (with restricted functionality), and USB interface cable for PC connectivity. Feedthrough cable terminator, 50 Ω (one per channel, 190-50x only).
Optional configuration Each model is available as a ‘boxed’ version, described above, or with the optional SCC293 set included. SCC293 comprises: CXT293 rugged protective carrying case, full-version FlukeView PC software (activation code) and a WiFi dongle for wireless PC-connectivity using FlukeView-2 software.
Optional accessories SCC293, VPS101 - 1:1 voltage probe; VPS510-x - wide bandwidth compact probes; i400s–current clamp; HH290–hanging hook; CXT293–protective carrying case; TRM50–BNC Feedthrough cable terminator, 50 Ω, safety designed; EBC290–battery charging bay

 

Oscilloscopes/Portable Oscilloscopes Template
Bandwidth 100 MHz
Channels 4
Sampling Rate 1.25 GS/S (1250 MS/S)
Screen Type (Oscilloscopes) LCD
Isolated Inputs Yes
Screen Size 5.3 IN
Color Screen Yes
Rise Time 3.5 ns
Memory 10000 Points (0.00098 kB)
Product Weight 4.8 LBS
Shipping Weight 5.52 LBS
MEMBER PRICE: INACTIVE
List price:   $5,825.24
Notify me when price changes $

Related products

Probes

Accessories

Recently viewed products

  • Catalog #: 5282442 2-Channel Color ScopeMeter with DMM/External Input and SCC-293 Kit, 200 MHz

    $5,825.24
We Ship Worldwide
Australia
Write us quote request in any language and then immediately translate it to English on our site.
Brazil
Envíenos su solicitud en cualquier idioma, que luego se traducen automáticamente en Inglés en nuestro sitio web.
Chile
Envíenos su solicitud en cualquier idioma, que luego se traducen automáticamente en Inglés en nuestro sitio web.
China
您的要求发送给我们以任何语言,它会自动翻译成英文在我们的网站。
France
Envoyez-nous votre demande dans n'importe quelle langue, qui seront ensuite automatiquement traduites en anglais sur notre site.
Germany
Schreiben Sie uns Ihre Anfrage in jeder beliebigen Sprache, diese wird dann auf unserer Website automatisch ins englische übersetzt.
India
हमें किसी भी भाषा में आपके अनुरोध है, जो स्वचालित रूप से हमारी वेबसाइट पर अंग्रेजी में अनुवाद हो जाएगा भेजें.
Italy
Inviaci la tua richiesta in qualsiasi lingua, che sarà automaticamente tradotto in inglese sul nostro sito web.
Japan
任意の言語で、その後は自動的に英語に当社のウェブサイト上に翻訳されますあなたのリクエストを送ってください。
Mexico
Envíenos su solicitud en cualquier idioma, que luego se traducen automáticamente en Inglés en nuestro sitio web.
Norway
Send oss din forespørsel på alle språk, som deretter automatisk oversatt til engelsk på våre nettsider.
Philippines
Ipadala sa amin ang inyong kahilingan sa kahit anong wika, na awtomatikong masasalin sa Ingles sa aming website.
Portugal
Envíenos su solicitud en cualquier idioma, que luego se traducen automáticamente en Inglés en nuestro sitio web.
Russian Federation
Отправьте нам свой запрос на любом языке, который будет автоматически переведен на английский на нашем сайте.
Spain
Envíenos su solicitud en cualquier idioma, que luego se traducen automáticamente en Inglés en nuestro sitio web.
United Kingdom
Write us quote request in any language and then immediately translate it to English on our site.
Quote Request
Portuguese Spanish German Hindi Italian Russian
English
Write us quote request in any language and then immediately translate it to English on our site
We Accept Payments
Usamultimeters.com BBB Business Review
Copyright © 2008-2024 usamultimeters.com All Rights Reserved
Products Manufactures Quote Request Resources Cart