AEMC 6422
Catalog #: 2135.55
Digital, 3-Point Ground Resistance Tester
- Overview
- Specifications
- Summary
- Accessories
Product Highlights
- Simple, one button operation - eliminates errors in testing
- Test button turns green when measurement is stable
- 2P resistance/ 3P ground resistance measurement up to 50kΩ for highly resistive terrain
- Large back lit digital display - easier to read in all lighting conditions
- Automatic hold function - retains last measurement after the reading stabilizes
- Automatic test frequency selection between 128 and 256 Hz
- Powers up in 2 pole mode - automatically checks the injector lead connection when connected to the H auxiliary rod
- Convenient storage of the three measurements along with the average and % deviation
- Built in test lead compensation capability
- CAT IV 600V rated for a high level of operator safety
- Color coded leads and terminals provide fast, error-free connection hook-up
- Detects and prohibits hazardous voltage measurement
- Direct access to all functions, even when wearing work gloves
- Rugged water resistance case, for all terrain use
- Built-in display stand to prop up instrument for seeing the display better when placed on the ground
Each Unit Includes
- 1 - 6422 (2135.55) Ground Tester
- 6 - AA Alkaline Batteries
- 1 - Soft Carrying bag
- 1 - User Manual
MODELS |
6422 |
6424 |
ELECTRICAL |
Voltage |
|
Range |
- |
0.1-600Vac/dc |
Resolution |
|
0.1V |
Accuracy |
|
±(1%R + 1ct) |
Current |
Range |
- |
0.5-60.00Aac (requires optional MN72 probe) |
Resistance (2P Mode) |
Measurement Range |
0.05-99.99Ω, 80.0-999.9Ω , 0.800-9.999kΩ, 8.00-50.00kΩ |
Resolution |
0.01Ω, 0.1Ω, 1Ω, 10Ω |
Intrinsic Uncertainty |
± (2%R + 10 ct), ± (2%R + 2 ct), ±(2%R + 1 ct), ±(2%R + 1 ct) |
Ground Resistance (3P Mode) |
Measurement Range |
0.50-99.99Ω |
80.0-999.9Ω |
0.800-2.000kΩ |
0.50-99.99Ω |
80.0-999.9Ω |
0.800-9.999kΩ |
8.00-50.000kΩ |
Resolution |
0.01Ω |
0.1Ω |
1Ω |
0.01Ω |
0.1Ω |
1Ω |
10Ω |
Intrinsic Uncertainty |
± (1%R + 10ct) |
± (1%R + 2ct) |
± (1%R + 1ct) |
± (1%R + 10ct) |
± (1%R + 2ct) |
± (1%R + 1ct) |
Measurement Frequency |
128Hz or 256Hz (automatically selected) |
No-load Voltage |
±10 V peak |
Maximum Test Current |
20mA |
Measurement Mode |
One shot or continuous |
Data Storage |
- |
Stores the 52%, 62% and 72% 3P resistance measurements |
Calculation |
- |
Calculates average and % deviation of the three saved readings |
GENERAL |
Display |
Backlit LCD |
Measurement Mode |
2P (Ω), 3P (Ω) |
V, I, 2P (Ω), 3P (Ω) |
Power Supply |
(6) AA Alkaline batteries |
(6) NiMH rechargeable batteries, charging time approx. 6 hrs |
Battery Life |
> 2,000 x 3P earth measurements at 100 Ω |
>1,500 x 3P earth measurements at 100 Ω |
Dimensions |
8.78 x 4.96 x 2.75" (223 x 126 x 70mm) |
|
|
|
|