|
|
Additel ADT878PC-700-B-110V
Catalog #: ADT878PC-700-B-110V
Reference Dry Well Calibrator
- Overview
- Specifications
- Summary
Product Highlights
- Temperature ranges:
- 160: -40 to 320°F
- 425: 91.4 to 797°F
- 700: 91.4 to 1292°F
- Accuracy:
- 160: ±0.1°C at full range
- 425: ±0.2°C at Full Range
- 700: ±0.20°C at 33°C/425°C and ±0.25°C at 660°C
- Full HART communicator
- Wi-Fi and Bluetooth capable
- Color touch screen display
- Quick-Push connectors (PC Option)
- Set point control by reference
- Self calibration
- Built-in automatic annealing (ADT878-700 only)
Each Unit Includes
- Dry block and selected insert
- Power cable
- USB cable
- Insert removal tool
- Certificate of calibration
- CD manual
Temperature Range at 23°C |
33°C to 700°C |
Display Accuracy |
±0.20°C at 33°C
±0.20°C at 425°C
±0.25°C at 660°C |
Stability (30 min) |
±0.005°C at 100°C
±0.015°C at 425°C
±0.030°C at 700°C |
Axial Uniformity at 60 mm (2.4 in) |
±0.10°C at 100°C
±0.25°C at 425°C
±0.40°C at 700°C |
Axial Uniformity at 80 mm (3.15 in) |
±0.15°C at 100°C
±0.30°C at 425°C
±0.60°C at 700°C |
Radial Uniformity |
±0.025°C at 100°C
±0.040°C at 425°C
±0.060°C at 700°C |
Lading Effect |
±0.02°C at 100°C
±0.05°C at 425°C
±0.15°C at 700°C
±0.01°C at 100°C
±0.02°C at 425°C
±0.03°C at 700°C |
Hysteresis (Display Sensor) |
0.07°C |
Environmental Conditions |
8°C to 38°C guaranteed accuracy
0°C to 50°C, 0% to 90% RH non-condensing |
Storage Conditions |
-20°C to 60°C |
IP Rating |
IP20 |
Immersion Depth |
193 mm (7.60 in) |
Insert OD |
30.8 mm (1.21 in) |
Heating Time |
25 min: 23°C to 700°C |
Cooling Time |
30 min: 700°C to 100°C
15 min: 100°C to 50°C |
Typical Time to Stability |
10 min |
Resolution |
0.001°C |
Units |
°C, °F, and K |
Display |
6.5 in (165 mm) color touch screen |
Size (H x W x D) |
170 x 345 x 330 mm (6.69 x 13.58 x 13.0 in) |
Weight |
9.7 kg (21.4 lbs) |
Power Requirements |
90-254 VAC, 45-65 Hz, 1400 W |
Communication |
USB A, USB B, RJ45, WiFi, Bluetooth |
Localization |
English, Chinese, Japanese, Russian, German, French, Italian, and Spanish |
Warranty |
1 year |
Input Specifications (Process Calibrator [PC] Option) |
Readout Accuracy for 100 ohm PRT (Probe Accuracy Not Included) |
±0.006°C at 0°C
±0.008°C at 50°C
±0.009°C at 100°C
±0.011°C at 160°C
±0.015°C at 300°C
±0.019°C at 425°C
±0.026°C at 660°C
±0.028°C at 700°C |
Readout Resolution |
0.1 mΩ |
Reference Resistance Range |
-200Ω to 926Ω |
Reference Resistance Accuracy |
0Ω to 50Ω: ±1.25mΩ
50Ω to 400Ω: ±0.0025% RD |
Reference Characterizations |
ITS-90, CVD, IEC-751 |
Reference Measurement Capability |
4-wire PRT |
Reference Probe Connection |
6-pin lemo smart connector and Quick-Push connectors to accept banana, mini-banana, large & small spade lug and bare wire connections |
RTD Channels |
2 |
RTD Measurement Accuracy (excl sensor) Compliance |
0Ω to 50Ω: ±2.5mΩ
50Ω to 4000Ω: ±0.005% RD |
RTD Measurement Resolution |
0.1mΩ |
RTD Measurement Resistance Range |
0Ω to 4KΩ |
RTD Characterizations |
PT10, PT25, PT50, PT100, PT200, PT500, PT1000, CU10, CU50, CU100, NI100, NI120 |
RTD Connection |
Quick-Push connectors accept banana, mini-banana, large & small spade lug and bare wire connections |
RTD Channels |
2 channels. Both accept 2, 3, or 4-wire RTDs |
TC Channel |
2 |
TC Measurement Channels |
Accepting S, R, K, B, N, E, J, T, C, D, G, L, and U |
TC Range |
-75 mV to 75 mV |
TC Resolution |
0.1µV |
TC Voltage Accuracy |
0.01% RD + 5 µV |
Internal CJC Accuracy |
±0.2°C (ambient from 0°C to 50°C) |
Current Range |
-30 mA to 30 mA |
Current Accuracy |
0.01% RD + 2 µA |
Current Resolution |
0.1 µA, Input Impedance: < 10Ω |
Voltage Range |
-30 V to 30 V |
Voltage Accuracy |
±0.01% RD + 0.6 mV |
Voltage Resolution |
0.1 mV; Input impedance: >1MΩ |
Switch Test |
Mechanical or Electrica |
DC 24V Output |
24 V ±0.5 V, MAX 60 mA |
Hart Communicator |
Read, configure and calibrate HART devices - DD files updated periodically Optional - (order ADT875PC) |
Documentation |
Up to 1,000 tasks which store up to 10 results each containing as found and as left data. Snap shot feature allows for screen captures. Records auto step and ramp functions. |
Temperature Coefficient 0℃ to 13℃ and 33℃ to 50℃ |
ADT878 (PC)-160: ±0.005°C/°C
ADT878 (PC)-425/700: ±0.005°C/°C
Ref Readout: ±1 ppm FS/°C
RTD Readouts: ±1 ppm FS/°C
TC Readouts: ±5 ppm FS/°C
Current: ±5 ppm FS/°C
Voltage: ±5 ppm FS/°C |
TC Measurement Specification and Calculation (Process Calibrator [PC] Option) |
TC Type |
Temperature (°C) |
Error (°C) [1] |
B |
250 |
±1.99 |
300 |
±1.65 |
425 |
±1.18 |
660 |
±0.81 |
700 |
±0.77 |
1768 |
±0.56 |
K |
-200 |
±0.29 |
-40 |
±0.13 |
0 |
±0.13 |
160 |
±0.14 |
300 |
±0.15 |
425 |
±0.16 |
660 |
±0.18 |
700 |
±0.19 |
1000 |
±0.31 |
E |
-200 |
±0.16 |
-40 |
±0.09 |
0 |
±0.09 |
160 |
±0.08 |
300 |
±0.09 |
425 |
±0.10 |
660 |
±0.12 |
700 |
±0.13 |
1000 |
±0.17 |
J |
-210 |
±0.22 |
-40 |
±0.10 |
0 |
±0.10 |
160 |
±0.11 |
300 |
±0.12 |
425 |
±0.13 |
660 |
±0.14 |
700 |
±0.14 |
1000 |
±0.21 |
T |
-200 |
±0.28 |
-40 |
±0.14 |
0 |
±0.13 |
160 |
±0.11 |
300 |
±0.11 |
400 |
±0.11 |
N |
-200 |
±0.46 |
-40 |
±0.20 |
0 |
±0.19 |
160 |
±0.17 |
300 |
±0.17 |
425 |
±0.17 |
660 |
±0.19 |
700 |
±0.19 |
1000 |
±0.27 |
S |
-50 |
±1.25 |
-40 |
±1.17 |
0 |
±0.93 |
160 |
±0.63 |
300 |
±0.57 |
425 |
±0.55 |
660 |
±0.54 |
700 |
±0.53 |
1768 |
±0.66 |
R |
-50 |
±1.33 |
-40 |
±1.23 |
0 |
±0.95 |
160 |
±0.61 |
300 |
±0.54 |
425 |
±0.51 |
660 |
±0.48 |
750 |
±0.18 |
1768 |
±0.58 |
[1] Excluding cold junction compensation errors. |
HTS/Schedule B Number |
9025.80.10 |
|
|
|
|