				Extech HD780
                
                
                
 			 
            
			
				Catalog #: HD780
 Dual-Input Digital Manifold/Pressure Gauge, Heavy Duty with Type-K Inputs
			 
			 
              
            
                
                    - Overview
 
                    - Specifications
 
                    - Summary
 
                    
                    
                    
                 
                	
                    
				        
                        Product Highlights 
    - Dual differential inputs for pressure and temperature
 
    - Displays 5 types of pressure units
 
    - For use with R22 and R410A refrigerants
 
    - Standard 1/4 NPT male flare fittings
 
    - Large backlit LCD displays P1, P2, P1-P2, T1, T2, T1-T2, Ambient Temperature, plus Min/Max/Avg
 
    - Dual Type K inputs with Electronic Offset adjustment to compensate for thermocouple differences
 
    - Large multi-line backlit LCD display
 
    - Data Hold plus Auto power off
 
 
                        Each Unit Includes 
    - 2 - Heavy Duty Pressure Hoses
 
    - 1 - Protective Rubber Holster
 
    - 2 - Type K Temperature Clamp Probes
 
    - 2 - General Purpose Type K Bead Wire Temperature Probes
 
    - 1 - Universal AC Adaptor with Plugs (US, EU, UK, AUS)
 
    - 1 - 9V Battery
 
    - 1 - Hard Case
 
 
                            
                    
                          
    
        
            | Pressure/Vacuum | 
            Range | 
            Resolution | 
            Basic Accuracy | 
         
        
            | psi | 
            -14 to 500psi | 
            0.1psi | 
            ±1psi | 
         
        
            | bar | 
            -0.96 to 34.47bar | 
            0.01bar | 
            ±0.1bar | 
         
        
            | kPa | 
            -96 to 3447kPa | 
            1kPa | 
            ±7kPa | 
         
        
            | inHg | 
            -28 to 999.9inHg | 
            0.1inHg | 
            ±2inHg | 
         
        
            | cmHg | 
            -72 to 2585cmHg | 
            1cmHg | 
            ±5cmHg | 
         
        
            | Temperature (Type K) | 
            -76°F to 999.9°F (-60°C to 537.0°C) | 
            0.1°F/°C | 
            ±(0.15%rdg + 1.8°F/1°C) | 
         
        
            | Temperature (Ambient - NTC) | 
            32.0°F to 122.0°F (0°C to 50.0°C) | 
            0.1°F/°C | 
            ±2°F/1°C | 
         
        
            | Maximum Overload Pressure | 
            800psi | 
            ±(4.0%+20d) | 
            - | 
         
        
            | Dimensions | 
            8.3 x 3.1 x 2" (212 x 78 x 51mm) | 
         
        
            | Weight | 
            11.9oz (338g) | 
         
    
 
                     
                      
    
        
            | ECCN Number | 
            EAR99 | 
         
        
            | Country of Origin | 
            China | 
         
    
  
                    
                    
                    
                   
                        
              
		 | 
	 
 
				 
				
					
				 
				
					
				 
				
				 
				
			 
		 | 
	 
 
    
     
    
								 | 
							 
						 
					 |