				Amprobe ALC-110
                
                
                
 			 
            
			
				Catalog #: 4930876
 True-RMS AC Leakage Current Clamp with Mechanical Lock Jaw, 6000 Counts Digit Large Scale
			 
			 
              
            
                
                    - Overview
 
                    - Specifications
 
                    - Summary
 
                    
                    
                    
                 
                	
                    
				        
                        Product Highlights
    - Low influence of      external low frequency magnetic fields: @ IN: 3.500 mA - 600.0 mA ≤ 30      A/m, operating class 2
 
    - True-rms      measurements for accuracy when measuring complex, non-sinusoidal waveforms
 
    - Mechanical jaw lock      - jaw opening 1.2 in (30 mm)
 
    - Highest resolution      of 0.001 mA, measure up to 60 A
 
    - Broad frequency      range 15 Hz to 1 kHz
 
    - Selectable filters:
    
        - Low Pass 50/60Hz       filter to perform measurements on equipment driven by Variable Frequency       Drives (VFDs) or affected by high frequency noise
 
        - Appliance Filter       to conduct leakage current measurements on appliances
 
        - No filter
 
     
     
    - Selectable limits:      0.25 mA, 0.5 mA, 3.5 mA, 10 mA, 12 mA
 
    - Max readings and      hold function
 
    - High safety rating:      CAT III 600 V
 
    - Battery-saving      design with an auto backlight off and auto power off
 
 
Applications
    - Measure:
    
        - Earth and       differential leakage currents
 
        - Leakage currents       through the earth (PE) conductor
 
        - Appliance current       consumption without interruptions to the circuit
 
     
     
 
       
    - Trace the source of      earth leakage current
 
    - Identify      intermittent GFCI trips without switching equipment off
 
    - Check a system for      an electrical break of insulation where current is flowing to the ground
 
    - Where industrial      leakage current testing is required
 
 
                        Each Unit Includes
    - 2 - 1.5 V AAA batteries
 
    - 1 - User manual
 
    - 1 - Soft carrying case
 
 
                            
                    
                          
    
        
            | AC current [1] [2] [3] | 
         
        
            | Range | 
            Resolution | 
            Accuracy | 
         
        
            | 15 Hz to 40 Hz | 
            > 40 Hz to 50 Hz | 
            > 50 Hz to 60 Hz | 
            > 60 Hz to 1 kHz | 
         
        
            | 6.000 mA | 
            0.001 mA | 
            ±(5.0%+5D) | 
            ±(2.0%+5D) | 
            ±(1.0%+5D) | 
            ±(2.0%+5D) | 
         
        
            | 60.00 mA | 
            0.01 mA | 
            ±(5.0%+5D) | 
            ±(2.0%+5D) | 
            ±(1.0%+5D) | 
            ±(2.0%+5D) | 
         
        
            | 600.0 mA | 
            0.1 mA | 
            ±(5.0%+5D) | 
            ±(2.0%+5D) | 
            ±(1.0%+5D) | 
            ±(2.0%+5D) | 
         
        
            | 6.000 A | 
            0.001 A | 
            Unspecified | 
            ±(2.0%+5D) | 
            ±(1.0%+5D) | 
            ±(2.0%+5D) | 
         
        
            | 60.00 A | 
            0.01 A | 
            Unspecified | 
            ±(2.0%+5D) | 
            ±(1.0%+5D) | 
            ±(2.0%+5D) | 
         
        
            [1] Crest Factor (C.F.) may be up to 3.0 as 3000 counts. For non-sinusoidal waveforms: Add 1.0% for C.F. 1.0 to 2.0 / Add 2.5% for C.F. 2.0 to 2.5 / Add 4.0% for C.F. 2.5 to 3.0. Position error of clamp: +/- 1% of LCD reading. 
            [2] Minimum reading is 0.010 mA. 
            [3] When operating in magnetic fields up to ≤ 30 A/m, add ±0.3 mA error to accuracy | 
         
    
 
  
    
        
            | General Specifications | 
         
        
            | Complies with IEC/EN 61557-13 | 
            • | 
         
        
            | Built according IEC/EN 61010-2-032 | 
            • | 
         
        
            | Low frequency magnetic fields | 
            ≤ 30 A/m, operating class 2 @ IN : 3.500 mA to 600.0 mA / 40 Hz to 1 kHz | 
         
        
            | Safety, measurement category | 
            CAT III 600 V | 
         
        
            | True-rms | 
            • | 
         
        
            | AC frequency | 
            15 Hz to 1 kHz | 
         
        
            | Low pass filter | 
            50 Hz to 60 Hz, for appliance measuring acc. EN61557-16 amendment A, no filter | 
         
        
            | Limit judgement | 
            0.25 mA, 0.5 mA, 3.5 mA, 10 mA, 12 mA | 
         
        
            | Jaw opening | 
            1.2 in (30 mm) max. | 
         
        
            | Jaw locking | 
            • | 
         
        
            | Data hold | 
            • | 
         
        
            | Backlight function | 
            • | 
         
        
            | Overload protection | 
            60 A | 
         
        
            | Auto power off Idle | 
            20 minutes | 
         
        
            | Auto ranging | 
            • | 
         
        
            | Max hold | 
            • | 
         
        
            | Display | 
            Digital: 6000 counts, updates 5/sec | 
         
        
            | Range | 
            Auto ranging | 
         
        
            | Over range indication | 
            OL or -OL | 
         
        
            | Operating temperature | 
            32 °F to 86 °F (0 °C to 30 °C), ≤ 80% RH 
            86 °F to 104 °F (30 °C to 40 °C), ≤ 75% RH 
            104 °F to 122 °F (40 °C to 50 °C), ≤ 45% RH | 
         
        
            | Operating altitude | 
            ≤ 2000 m | 
         
        
            | Storage temperature | 
            -4 °F to 140 °F (-20 °C to 60 °C) | 
         
        
            | Pollution degree | 
            2 | 
         
        
            | Temperature coefficient | 
            0.1 x (specified accuracy) / °C (<21 °C, >25 °C) | 
         
        
            | Vibration requirement | 
            acc. IEC 61557-1 clause 4.10 | 
         
        
            | Drop proof | 
            4 ft (1.2 m) | 
         
        
            | Battery | 
            2 x batteries 1.5 V IEC LR03 AAA | 
         
        
            | Battery life | 
            60 hours typical | 
         
        
            | Low battery indication | 
            (- +) | 
         
        
            | Safety compliance | 
            IEC/EN 61010-1, IEC/EN 61010-2-032, IEC/EN 61557-13 | 
         
        
            | EMC compliance | 
            IEC/EN 61326-1, IEC/EN 61326-2-2 | 
         
        
            | Agency approvals | 
            CE | 
         
        
            | Dimensions (H x W x L) | 
            8.7 x 3.5 x 1.8 in (221 x 89 x 48 mm) | 
         
        
            | Weight | 
            0.9 lb (410 g) with batteries installed | 
         
    
 
                     
                      
    
        
            | Clamp Meters/Current Clamp Adaptors / Current Clamps Template | 
         
        
            | CAT Rating | 
            III | 
         
        
            | CAT Voltage Rating (V) | 
            600V | 
         
        
            | Battery Powered | 
            Yes | 
         
        
         
        
            | Safety Approval | 
            CE | 
         
        
            | Product Weight | 
            0.90 LBS | 
         
        
            | Product Height | 
            8.7 IN | 
         
        
            | Product Length | 
            1.8 IN | 
         
        
            | Product Width | 
            3.5 IN | 
         
        
            | HTS/Schedule B Number | 
            9030310000 | 
         
        
            | ECCN Number | 
            3A992 | 
         
        
            | Battery Type | 
            AAA | 
         
        
            | Power Supply Voltage | 
            Battery Powered | 
         
        
            | Country of Origin | 
            Taiwan | 
         
        
            | Shipping Height | 
            3.80 IN | 
         
        
            | Shipping Length | 
            12.50 IN | 
         
        
            | Shipping Width | 
            7.00 IN | 
         
    
  
                    
                    
                    
                   
                        
              
		 | 
	 
 
				 
				
					
				 
				
					
				 
				
				 
				
			 
		 | 
	 
 
    
     
    
								 | 
							 
						 
					 |