|
|
Fluke 80i-2010s/3PK
Catalog #: 5125587
AC/DC Current Clamp, 2000 AAC rms, ± 2000 ADC (Pack of 3)
- Overview
- Specifications
- Summary
Product Highlights
- Three (3) lamp-on current probes
- Modules: 80i-2010s
- Dimensions: 110 mm x 270 mm x 46mm
- Weight: 0.710 kg (1.6 lbs), including battery
- Output cable: 1.5 m (60 in) Shielded Coaxial cable with BNC plug
- Maximum conductor: Size 52.0 mm (2.05 in)
- Maximum jaw opening: 81.5 mm
- Output to zero: Auto adjustment with Zero button
- Temperature operating: -10 °C to 50 °C (14 °F to 122 °F)
- Storage (battery removed): -30 °C to +60 °C (-22 °F to +140 °F)
- Operating humidity: ≤ 90 % RH (at 10 °C to 30 °C) ≤ 75 % RH (at 30 °C to 40 °C) ≤ 45 % RH (at 40 °C to 50 °C)
- Altitude: Operating 2,000 m (6560 ft)
- Storage: 12,000 m (40,000 ft)
- Demagnetize clamp: Open and close the Clamp jaws several times with soft click, use of clamp on uninsulated conductors is limited to 1000 Vac rms or DC and frequencies 1 kHz or less
- Safety: IEC 61010-1, Pollution Degree 2, IEC 61010-2-032: CAT III 1000 V /CAT IV 600 V
- Ingress: Protection IEC 60529, IP40
- Power supply: Type 2 x AA alkaline battery, IEC LR6
- Battery life: 150 hours (typically)
- Low battery indicator: Yes
General Specifications |
Modules |
80i-2010s |
Dimensions |
110 mm x 270 mm x 46mm |
Weight |
0.710 kg (1.6 lbs), including battery |
Output Cable |
1.5 m (60 in) Shielded Coaxial cable with BNC plug |
Maximum Conductor Size |
52.0 mm (2.05 in) |
Maximum Jaw Opening |
81.5 mm |
Output to Zero |
Auto adjustment with Zero button |
Temperature Operating |
-10 °C to 50 °C (14 °F to 122 °F) |
Storage (battery removed) |
-30 °C to +60 °C (-22 °F to +140 °F) |
Operating Humidity |
≤ 90 % RH (at 10 °C to 30 °C) ≤ 75 % RH (at 30 °C to 40 °C) ≤ 45 % RH (at 40 °C to 50 °C) |
Operating Altitude |
2,000 m (6560 ft) |
Storage Altitude |
12,000 m (40,000 ft) |
Demagnetize Clamp |
Open and close the Clamp jaws several times with soft click, use of the clamp on uninsulated conductors is limited to 1000 Vac rms or DC and frequencies 1 kHz or less. |
Safety |
IEC 61010-1, Pollution Degree 2, IEC 61010-2-032: CAT III 1000 V /CAT IV 600 V |
Ingress Protection |
IEC 60529, IP40 |
Power Supply Type |
2 x AA alkaline battery, IEC LR6 |
Battery Life |
150 hours (typically) |
Low battery indicator |
Yes |
Electrical Specifications |
Current Range |
2000 A ac rms, ± 2000 A dc |
Output Sensitivity |
01 mV/A |
Accuracy |
± 0.8 % of reading ± 0.2 % of range |
Bandwidth for Accuracy Specification |
DC to 400 Hz |
Load impedance |
>1 MΩ and <10 pF |
Frequency Response (small signal) |
DC to 20 kHz (-3 dB) |
Temperature Coefficient |
0.1 x specified accuracy for each degree C above 28 °C or below 18 °C |
Working Voltage |
1000 V AC RMS or DC |
Clamp Meters/Current Clamp Adaptors / Current Clamps Template |
|
2000 A |
AC/DC Current |
Yes |
Current Accuracy |
± 0.8 |
Maximum Conductor Size Fixed |
2.05 IN |
|
III |
Battery Powered |
Yes |
Warranty |
1 YEARS |
|
IP40 |
Product Weight |
4.8 LBS |
Product Height |
10.63 IN |
Product Length |
1.81 IN |
Product Width |
4.33 IN |
Shipping Weight |
6 LBS |
HTS/Schedule B Number |
9030.90.8931 |
ECCN Number |
3A992 |
Country of Origin |
China |
Shipping Height |
9.00 IN |
Shipping Length |
10.00 IN |
Shipping Width |
9.00 IN |
|
|
|
|