|
|
Fluke Networks OFP2-100-MI
Catalog #: 4955271
OptiFiber Pro Multi-Mode OTDR, 850/1300 nm with Inspection Kit, Wi-Fi Adapter
- Overview
- Specifications
- Summary
- Accessories
Product Highlights
- Includes Multi-mode OTDR Modules, FiberInspector Pro, and a WiFi adapter to connect the Versiv 2 Mainframe to Linkware Live
- SmartLoop OTDR enables automated testing and analysis of two fibers in a single test, eliminating the need to travel to the far end of the connection to perform tests.
- Taptive user interface puts advanced data analysis and easy set-up and operation at the fingertips of of technicians of all skill levels.
- Linkware Live enables to easily track job progress, get real-time access to test results to quickly fix problems in the field, and easily transfer and consolidate test results from the tester to LinkWare PC Cable Test Management Software.
Performance:
- Test times as short as two seconds in Quick Test mode
- Quickly test datacenter fiber with pre-programmed settings
- Troubleshoot datacenter fiber links with short patch cables and many connectors because of ultra short dead zones
- Easily characterize all connectrs, splices and areas of high loss with graphical EventMap view
- Pass/Fail certification of fiber optic connector endfaces
- ProjX management system increases return on investment by enabling OTDR
- Reduce network downtime by quickly and precisely identifying faults on all fiber types
- Built-in Visual Fault Locator (VFL) easily identifies damaged fibers.
Standards:
- Full OTDR capability that certifies fiber performance based on industry standards or customer specifications
- Complaint with ISO and TIA standards
Each Unit Includes
- 1 - Versiv 2 Mainframe
- 1 - OptiFiber Pro Multi-mode OTDR module
- 1 - WiFi Adapter for Versiv 2 Mainframe
- 1 - Shoulder Strap
- 1 - USB Interface Cable
- 1 - Versiv 2 Open Source Software CD
- 1 - AC Charger
- 2 - Quick Cleaners (1.25/2.50 mm)
- 2 - SC/LC Multi-mode Launch Cables-50 µm
- 2 - OTDR source port interchangeable LC adapters
- 1 - USB Fiber Inspection Video Probe with 4 Tips
- 1 - SC/SC Simplex Adaptor
- 2 - Launch Fiber Hanging straps and magnets
- 1 - Statement of Calibration and Getting Started Guides
Key OTDR specifications |
|
Multimode module |
Singlemode module |
Quad module |
Wavelengths |
850 nm +/- 10 nm
1300 nm +35/-15 nm |
1310 nm +/- 25 nm
1550 nm +/- 30 nm |
850 nm +/- 10 nm
1300 nm +35/-15 nm
1310 nm +/- 25 nm
1550 nm +/- 30 nm |
Compatible fiber types |
50/125 µm
62.5/125 µm |
Singlemode |
50/125 µm
62.5/125 µm
Singlemode |
Event dead zone 1 |
850 nm: 0.5 m typical
1300 nm: 0.7 m typical |
1310 nm: 0.6 m typical
1550 nm: 0.6 m typical |
850 nm: 0.5 m typical
1300 nm: 0.7 m typical
1310 nm: 0.6 m typical
1550 nm: 0.6 m typical |
Attenuation dead zone 2 |
850 nm: 2.5 m typical
1300 nm: 4.5 m typical |
1310 nm: 3.6 m typical
1550 nm: 3.7 m typical |
850 nm: 2.5 m typical
1300 nm: 4.5 m typical
1310 nm: 3.6 m typical
1550 nm: 3.7 m typical |
Dynamic range 3, 5, 6 |
850 nm: 28 dB typical
1300 nm: 30 dB typical |
1310 nm: 32 dB typical
1550 nm: 30 dB typical |
850 nm: 28 dB typical
1300 nm: 30 dB typical
1310 nm: 32 dB typical
1550 nm: 30 dB typical |
Max distance range setting |
40 km |
130 km |
MM: 40 km
SM: 130 km |
Distance measurement range 4, 5, 7, 8, 9, 10 |
850 nm: 9 km
1300 nm: 35 km |
1310 nm: 80 km
1550 nm: 130 km |
850 nm: 9 km
1300 nm: 35 km
1310 nm: 80 km
1550 nm: 130 km |
Reflectance range 4, 5 |
850 nm: -14 dB to -57 dB (typical)
1300 nm: -14 dB to -62 dB (typical) |
1310 nm: -14 dB to -65 dB (typical)
1550 nm: -14 dB to -65 dB (typical) |
850 nm: -14 dB to -57 dB (typical)
1300 nm: -14 dB to -62 dB (typical)
1310 nm: -14 dB to -65dB (typical)
1550 nm: -14 dB to -65 dB (typical) |
Sample resolution |
3 cm to 400 cm |
3 cm to 400 cm |
3 cm to 400 cm |
Pulse widths (nominal) |
850 nm: 3, 5, 20, 40, 200 ns
1300 nm: 3, 5, 20, 40, 200, 1000 ns |
1310/1550 nm: 3, 10, 30, 100, 300, 1000, 3000, 10000, 20000 ns |
850 nm: 3, 5, 20, 40, 200 ns
1300 nm: 3, 5, 20, 40, 200, 1000 ns
1310/1550 nm: 3, 10, 30, 100, 300, 1000, 3000, 10000, 20000 ns |
Test time (per wavelength) |
Auto setting: 5 sec (typical) |
Auto setting: 10 sec (typical) |
Auto setting:
MM - 5 sec (typical)
SM - 10 sec (typical) |
Quick test setting:
2 sec (typical) |
Quick test setting:
5 sec (typical) |
Quick test setting:
MM - 2 sec (typical)
SM - 5 sec (typical) |
Best resolution setting:
2 to 180 sec |
Best resolution setting:
5 to 180 sec |
Best resolution setting:
MM - 2 to 180 sec M
SM - 5 to 180 sec |
FaultMap setting:
2 sec (typical), 180 sec (max) |
FaultMap setting:
10 sec (typical), 180 sec (max) |
FaultMap setting:
MM - 2 sec (typical), MM - 180 sec (max)
SM - 10 sec (typical), SM - 180 sec (max) |
DataCenter OTDR setting:
1 sec (typical at 850 nm), 7 sec (max) |
DataCenter OTDR setting:
20 sec (typical), 40 sec (max) |
DataCenter OTDR setting:
MM - 1 sec (typical at 850 nm) MM - 7 sec (max)
SM - 20 sec (typical) SM - 40 sec (max) |
Manual setting:
3, 5, 10, 20, 40, 60, 90, 120, 180 sec |
Manual setting:
3, 5, 10, 20, 40, 60, 90, 120, 180 sec |
Manual setting:
-3, 5, 10, 20, 40, 60, 90, 120, 180 sec SM - 3, 5, 10, 20, 40, 60, 90, 120, 180 sec |
- Measured at 1.5 dB below non-saturating reflection peak with the shortest pulse width. Reflection peak < -40 dB for multimode and < - 50 dB for singlemode.
- Measured at +/- 0.5 dB deviation from backscatter with the shortest pulse width. Reflection peak < -40 dB for multimode and < - 50 dB for singlemode.
- For typical backscatter coefficient for OM1 fiber: 850: -65 dB, 1300: -72 dB.
- Typical backscatter and attenuation coefficients for OM2-OM4 fiber: 850 nm: -68 dB; 2.3 dB/km: 1300 nm: -76 dB; 0.6 dB/km.
- Typical backscatter and attenuation coefficients for OS1-OS2 fiber: 1310nm : -79 dB; 0.32 dB/km; 1550 nm: -82 dB; 0.19 dB/km.
- SNR = 1 method, 3 minute averaging, widest pulse width.
- 850 = 9 km typical to find the end or 7 km typical to find a 0.1 dB event (with a maximum of 18 dB attenuation prior to the event).
- 1300 = 35 km typical to find the end or 30 km typical to find a 0.1 dB event (with a maximum of 18 dB attenuation prior to the event).
- 1310 = 80 km typical to find the end or 60km typical to find a 0.1 dB event (with a maximum of 20 dB attenuation prior to the event).
- 1550 = 130 km typical to find the end or 90 km typical to find a 0.1 dB event (with a maximum of 18 dB attenuation prior to the event).
- Does not include index of refraction error and does not include automatic event location error.
- dB variation per 1 dB step.
- Applies along the trace backscatter within the distance range in which the OTDR can find a 0.1 dB event.
FiberInspector probe specifications |
Magnification |
~ 200X with OptiFiber Pro Display |
Light source |
Blue LED |
Power source |
TFS mainframe |
Field of View (FOV) |
Horizontal: 425 µm, Vertical: 320 μm |
Minimum detectable particle size |
0.5 µm |
Dimensions |
Approximately 6.75 in x 1.5 in (1175 mm x 35 mm) without adapter tip |
Weight |
200 g |
Temperature range |
Operating: 32°F to 122°F (0 °C to +50 °C), Storage: -4°F to +158°F (-20°C to +70°C) |
Product Height |
9.00 IN |
Product Length |
17.00 IN |
Product Width |
11.00 IN |
Country of Origin |
United States |
Shipping Height |
9.00 IN |
Shipping Length |
17.00 IN |
Shipping Width |
11.00 IN |
|
|
|
|