Fluke Networks FTK1475
Catalog #: 4812160
Simplifiber Singlemode 1310/1550, Multimode 850/1300 nm Verification Kit with FI-500 and VisiFault VFL
- Overview
- Specifications
- Summary
- Adapters
- Accessories
Product Highlights
- Fiber optic cable test kit with SimpliFiber Pro meter, single and multimode light sources, and other tools for verification and inspection of cabling in multimode and single mode fiber networks
- SimpliFiber Pro
- Optical power meter with both multimode and singlemode light sources measures power and loss using dual-wavelength testing, which simultaneously transmits 850 nm and 1300 nm wavelengths for the multimode source and 1310 nm and 1550 nm for the singlemode source
- Fiber Optic Inspection Scope
- includes a handheld color display, auto-focus inspection scope and 4 tips for LC and SC style bulkhead and 1.25 and 2.50mm patch cords.
- The patented scope includes PortBright to illuminate and easily connect in dark places
- VisiFault VFL
- Uses a bright red laser to trace fibers, checks continuity and polarity, and help find breaks in multimode and singlemode fiber
Each Unit Includes
- 1 - FI-500 FiberInspector
- 1 - SimpliFiber Pro Multimode & Singlemode PMLS
- 1 - VisiFault
- 2 - FindFibers
- 1 - Cleaning kit (NFC-KIT-BOX)
- 1 - 1.25 mm Swabs
- 1 - FindFiber remote ID
- 3 - power meter adapters (SC, ST, and LC)
- 1 - USB interface cable
- 1 - Quick reference guide
- 1 - Carrying Case
Temperature range |
Operating: -10 0C to 50 0C
Storage: -20 0C to 50 0C |
Humidity range |
95% (10 0C to 35 0C) non-condensing;
75% (35 0C to 40 0C) non-condensing;
uncontrolled <10 0C |
Certifications |
CE, CSA, N10140, Class 1 laser-safe |
Dimensions |
Power meter: 6.4 in x 3.2 in x 1.5 in (16.5 cm x 8.0 cm x 3.9 cm)
MM/SM sources: 5.6 in x 3.2 in x 1.6 in (14.2 cm x 8.1 cm x 4.1 cm) |
Weight |
Power meter: 11.5 oz (325 g)
MM/SM sources: 9.8 oz (278 g) |
Optical Sources |
Optical output connector |
Fixed SC |
Emitter type |
850/1300: LED
1310/1550: FP Laser
FindFiber: Laser |
Emitter wavelengths |
850, 1300, 1310, 1490, 1550, 1625 |
Power output (minimum) |
MM: ≥ -20 dBm
SM: ≥ 8 dBm minimum;
-7 dBm nominal |
Power output stability(8 hours) |
MM: +/- 0.1 dB over 8 hours
SM: +/- 0.25 dB over 8 hours |
MM battery life (2 x AA IEC LR6) |
40 hours typical |
SM battery life (2 x AA IEC LR6) |
30 hours typical |
FindFiber battery life (2 x AA IEC LR6) |
80 hours typical |
Optical Power Meter |
Power measurement accuracy |
+/-0.25 dB |
Optical connector |
Removable adapter; SC adapter standard;
Optional adapters include LC, ST |
Detector type |
InGaAs |
Calibrated wavelengths |
850, 1300, 1310, 1490, 1550, 1625 |
Power measurement range |
850: 10 to -52 dBm
1300, 1310, 1490, 1550, 1625: 10 to -60 dBm |
Power measurement linearity |
850 nm: +/- 0.2 dB; +/- 0.2 dB for power from 0 dBm to -45 dBm, +/- 0.25 dB for power < -45 dBm; 1300 nm, 1310 nm, 1490 nm, 1550 nm, 1625 nm: +/- 0.1 dB; +/- 0.1 dB for power from 0 dBm to -55 dBm, +/- 0.2 dB for power > 0 dBm and < -55 dBm |
Resolution |
0.01 dB |
Battery life |
>50 hours typical |
Memory |
1000 loss or power measurements |
Serial communication physical interface |
USB |
Product Height |
8.50 IN |
Product Length |
15.75 IN |
Product Width |
11.00 IN |
HTS/Schedule B Number |
9030.40.0000 |
ECCN Number |
3A992 |
Country of Origin |
United States |
Shipping Height |
8.50 IN |
Shipping Length |
15.75 IN |
Shipping Width |
11.00 IN |
|
|
|
|