| General Specification |
| Color alarms (temperature alarms) |
High temperature, low temperature, and isotherms (within range) |
| Infrared spectral band |
8 μm to 14 μm (long wave) |
| Operating Temperature |
-10 °C to +50 °C (14 °F to 122 °F) |
| Storage Temperature |
-40 °C to +70 °C (-40 °F to 158 °F) |
| Relative humidity |
95 % non-condensing |
| Center-point temperature |
Yes |
| Spot temperature |
Hot and cold spot markers |
| Safety |
EN 61010-1: CAT none, pollution degree 2, EN 60825-1: Class 2, EN 60529, EN 62133 (lithium battery) |
| Electromagnetic compatibility |
EN301 489-1 V2.1.1 EN301489-17 V3.1.1 |
| US FCC |
CFR, Part 15C |
| Vibration and shock |
2G, IEC 68-2-6 and 25G, IEC 68-2-29 |
| Drop |
1 meter |
| Size (H x W x L) |
8.9cm x 12.7cm x 2.5cm (3.5 in x 5.0 in x 1.0 in) |
| Weight |
0.233 kg (0.514 lb) |
| Enclosure rating |
IP54 |
| Warranty |
Two-years |
| Supported languages |
Czech, Dutch, English, Finnish, French, German, Hungarian, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, and Turkish |
| IFOV (spatial resolution) |
7.6 mRad |
| Infrared resolution |
120 x 90 (10,800pixels) |
| Field of view |
50° H x 38° V |
| Distance to spot |
130:1 |
| Temperature measurement range(not calibrated below -10 °C) |
-20 ° C to 150 ° C |
| Focus system |
Fixed focus, minimum focus distance 22.8 cm |
| USB |
Mini USB used to transfer image to PC |
| Wifi |
Yes |
| Fluke Connect® Instant Upload |
Yes, connect your camera to your building’s WiFi network, and images taken automatically upload to the Fluke Connect® system or your local server for storage and viewing on your PC (802.11 bgn (2.4 GHz)) |
| Image quality |
| IR-Fusion technology |
Yes, adds the context of the visible details to your infrared image |
| AutoBlend mode |
Continuous 0% to 100% |
| Touchscreen display |
3.5" (landscape), 320 x 240 LCD |
| Rugged, ergonomic design |
Yes |
| Thermal sensitivity (NETD) |
60 mK |
| Frame rate |
9 Hz |
| Data storage and image capture |
| Memory |
≥2 GB internal flash memory |
| Image capture, review, save mechanism |
One-handed image capture, review, and save capability |
| Image file formats |
Non-radiometric (jpeg), or fully radiometric (.is2); no analysis software required for non-radiometric (jpeg) files |
| Software |
Fluke Connect® desktop software—full analysis and reporting software with access to the Fluke Connect system |
| Export file formats with software |
JPG, IS2 |
| Measurement Range |
-20 °C~150 °C |
| Battery |
| Batteries (rechargable) |
Internal rechargeable lithium ion battery. |
| Battery life |
≥ 2 hours continuous (without WiFi) |
| Battery charging time |
≤ 1.5 hours |
| Battery charging system |
Micro USB cord from product to PC |
| AC operation |
With separate AC to USB adapter. Not included in box |
| Power saving |
Automatic Shutdown:
5, 10, 15 and 20 minutes or never |
| Temperature measurement |
| Temperature measurement range (not calibrated below -10 °C) |
-20 ° C to 150 ° C |
| Accuracy |
Target temp at or over 0 °C: Accuracy: ± 2° C or ± 2 % |
| On-screen emissivity correction |
Yes |
| On-screen reflected background temperature compensation |
Yes |
| Color palettes |
Standard palettes 6: Ironbow, Blue-Red, High Contrast, Amber, Hot Metal, Grayscale |