AEMC OX5042 w/ MN379T Kit
Catalog #: 2150.23
Handscope Model OX5042 Kit (2-Channel, 40MHz, MN379T, MiniFlex® 3000-24-1-1, BNC Lead)
- Overview
- Specifications
- Summary
Product Highlights
- Handscope Model OX5042 Kit (2-Channel, 40MHz, MN379T, MiniFlex® 3000-24-1-1, BNC Lead)
- 3.5" color LCD screen LED backlighting technology
- Integrated interactive multilingual help function
- 2MB recording data
- Store graphic recordings of 2700 measurements (5 min to 1 month)
- Communication via isolated USB SCPI protocol
- Two isolated channels
- Three instruments in one - 40MHz oscilloscope - Double 8000-count TRMS multimeter / Power analyzer - Harmonic analyzer
Each Unit Includes
- Meter
- Field case (IP67)
- BNC adapter
- USB cable and driver
- 1 10:1 600V/BNC-M probe
- US wall plug
- Set of 2 10 ft. color-coded (Rd/Bk) leads
- Alligator clips and test probes
- AC Current Probe Model MN379T (5A, 200nV/A & 100A, 10mV/A, 10ft. BNC Lead)
- MiniFlex® 3000-24-1-1 (3000A, 1mV/A, 24" MiniFlex® sensor, 10 ft. BNC connector)
- 6 1.2V NiMH rechargeable batteries
- Quick start guide
- USB drive with software
- User manual
General Specifications |
Interface |
Display |
3.5" color TFT LCD screen; Resolution 320 x 240 – LED backlighting |
Commands |
Direct adjustments on front panel & on-screen menus via browser (principal & secondary without “hidden menus”) |
Display Mode |
2500 real acquisition points on screen |
Display of Curves on Screen |
2 curves + 2 references + memory trace or mathematical calculation |
Integrated Interactive Help Function |
11 languages: French, English, German, Spanish, Italian, Swedish, Romanian, Russian, Finnish, Polish, Dutch |
Oscilloscope mode |
Vertical Deflection |
Bandwidth |
40MHz |
Bandwidth Limiter |
1.5MHz, 5kHz |
Number of Channels |
2 totally isolated channels |
Input Impedance |
1MΩ ±0.5%, approx. 17pF |
Maximum Input Voltage |
600V CAT III – Derating -20dB per decade from 100kHz |
Vertical Sensitivity |
5mV to 200V/div |
Horizontal deflection |
Sweep Speed |
25ns/div to 200s/div – Roll Mode from 100ms to 200s/div |
Horizontal Zoom |
Zoom factor: x1, x2, x5 |
Triggering |
Mode |
Automatic, triggered, one-shot & triggered Roll |
Type |
Edge, pulse width (20ns – 20s) |
Coupling |
AC or DC (depending on the coupling of the triggering channel) HF, LF or noise rejection |
Sensitive |
≤ 1.2 divisions p-p up to 40MHz |
Digital memory |
Maximum Sampling Rate |
2GS/s in ETS mode – 50MS/s in one-shot mode on each channel |
Vertical Resolution |
9 bits |
Memory Depth |
2500 points per channel |
User Storage |
2MB for storing files: trace (.trc), text (.txt), configuration (.cfg), image files (.bmp) |
Glitch Mode |
Duration ≥ 20ns – 1250 min/max pairs |
Display Modes |
Envelope, Averaging (factors 2 to 64) and XY (vector) |
Other Functions |
Math Functions |
Channel inversion, addition, subtraction, multiplication and division (adjustable scaling) |
Cursor Measurement |
2 cursors: V, T, dV, dt simultaneously – 4-digit display resolution |
Automatic Measurement |
18 time or level measurements and phase measurement |
Multimeter mode |
General Specifications |
2 channels, 8000-count display + min/max bargraph – Graphic recording of 2700 measurements (5min to 1 month) |
Operating Modes |
Absolute or relative display (absolute, deviation, ref, ref%) – Monitoring (instantaneous, min, max, Avg) |
AC, DC & AC+DC Voltages |
Ranges from 600mV to 600Vrms, 800mV to 800Vdc – accuracy for Vdc ±1% reading+20D –50kHz bandwidth |
Resistance |
Range from 80Ω to 32MΩ - accuracy ±2% reading + 10D –10ms quick continuity test |
Capacitance |
Ranges from 5nF to 5mF – basic accuracy ±2% reading + 10D |
Other Measurements |
Frequency, rotation speed, 3.3V diode test, temperature measurement (with K-type thermocouple or infrared probe) |
Power |
Measurements |
Single-phase and balanced three-phase active power values (with or without neutral), simultaneous display of current |
Harmonic analyzer mode |
Multi-Channel Analysis |
2 channels, 31 orders, fundamental frequency from 40 to 450Hz |
Simultaneous Measurements |
Total VRMS, THD and selected order (% fundamental, phase, frequency, Vrms) |
General |
Screenshots |
Up to 100 files in standard “.bmp” format, viewable on the instrument |
PC Communication |
isolated optical USB interface “SX-Metro” PC application software (included) |
Power Supply |
6 LR6 or 6AA NiMh batteries – Battery life up to 8hrs 30min
Universal line adapter isolated from the channels – Quick charging in 2hrs 30min |
Safety/EMC |
Safety according to IEC61010-1 Ed3 – 600V CAT III, EMC according to EN61000-3, 2001 & EN61326-1, 2006 |
Oscilloscopes/Portable Oscilloscopes Template |
Bandwidth |
40 Mhz |
Channels |
2 |
Sampling Rate |
2 GS/S (2000 MS/S) |
Screen Type (Oscilloscopes) |
TFT/LCD |
Isolated Inputs |
Yes |
Screen Size |
3.5 IN |
Color Screen |
Yes |
|
|
|
|