Fluke Calibration 9103-DW-156
Catalog #: 3015831
Dry-Well, -25C FIELD, No Insert
- Overview
- Specifications
- Summary
- Inserts
- Cases
- Accessories
Product Highlights
- Convenient handle
- RS-232 interface
- Universal AC input
- Built in programmable features include:
- Temperature scan rate control
- Temperature switch hold
- Eight set-point memory
- Adjustable readout in °C or °F
Each Unit Includes
- 9103 Dry-well
- Power Cord
- 9930 Software
- Serial Cable
- Manual
- NIST Traceable Calibration Certificate
Specifications |
|
9103 |
9140 |
9141 |
Range |
–25 °C to 140 °C
(–13 °F to 284 °F)
at 23 °C ambient |
35 °C to 350 °C
(95 °F to 662 °F) |
50 °C to 650 °C
(122 °F to 1202 °F) |
Accuracy |
± 0.25 °C (holes greater than 1/4" [6.35 mm]: ± 1 °C) |
± 0.5 °C (holes greater than 1/4" [6.35 mm]: ± 1 °C) |
± 0.5 °C to 400 °C;
± 1.0 °C to 650 °C
(holes greater than 6.35 mm: ± 2 °C) |
Stability |
± 0.02 °C at –25 °C
± 0.04 °C at 140 °C |
± 0.03 °C at 50 °C
± 0.05 °C at 350 °C |
± 0.05 °C at 100 °C
± ± 0.12 °C at 500 °C
± 0.12 °C at 650 °C |
Well-to-Well Uniformity |
± 0.1 °C between similarly sized wells |
± 0.1 °C with similarly sized wells |
± 0.1 °C below 400 °C,
± 0.5 °C above 400 °C
with similarly sized wells |
Heating Times |
18 minutes from ambient to 140 °C |
12 minutes from ambient to 350 °C |
12 minutes from ambient to 650 °C |
Cooling Times |
20 minutes from ambient to –25 °C |
15 minutes from 350 °C to 100 °C |
25 minutes from 650 °C to 100 °C |
Stabilization Time |
7 minutes |
Immersion Depth |
124 mm (4.875") |
Inserts |
Insert A, B, C, or D included (specify when ordering) |
Outside Insert Dimensions |
31.8 mm dia. x 124 mm (1.25 x 4.88 in) |
28.5 mm dia. x 124 mm (1.12 x 4.88 in) |
Computer Interface |
RS-232 included with free Interface-it software (Model 9930) |
Power |
115 V ac (± 10 %), 1.3 A or 230 V ac (± 10 %), 0.7 A, switchable, 50/60 Hz, 150 W |
115 V ac (± 10 %), 4.4 A or 230 V ac (± 10 %), 2.2 A, switchable, 50/60 Hz, 500 W |
115 V ac (± 10 %), 8.8 A or 230 V ac (± 10 %), 4.4 A, switchable, 50/60 Hz, 1000 W |
Size (WxHxD) |
143 x 261 x 245 mm
(5.63 x 10.25 x 9.63 |
152 x 86 x 197 mm
(6 x 3.375 x 7.75 in) |
109 x 236 x 185 mm
(4.3 x 9.3 x 7.3 in) |
Weight |
5.7 kg (12 lb) |
2.7 kg (6 lb) |
3.6 kg (8 lb) |
NIST-Traceable Certificate |
Data at –25 °C, 0 °C, 25 °C, 50 °C, 75 °C, 100 °C, and 140 °C |
Data at 50 °C, 100 °C, 150 °C, 200 °C, 250 °C, 300 °C, and 350 °C |
Data at 100 °C, 200 °C, 300 °C, 400 °C, 500 °C, and 600 °C |
Calibration Baths |
Type |
Dry |
Min Temp (Caiibration Baths) |
-25 C |
Max Temp (Calibration Baths) |
140 C |
Accuracy (Calibration Baths) |
0.25 C |
Voltage (Calibration Baths) |
115 VAC |
Special Features (Calibration Baths) |
Inserts Available (Dry Baths), PC Software |
Unique Features |
No Insert included. Purchase Separately |
Interfaces I/O |
RS-232 |
ECCN Number |
EAR99 |
Country of Origin |
United States |
|
Inserts
Cases
Product |
Price |
|
Fluke Calibration 9316
Catalog #: 1658649
Rugged Carrying Case for Fluke 9103 Dry-Well
|
$1,071.22
|
Accessories
|
|
|