Fluke 1550C FC Kit w/IR3000
Catalog #: 4977457
5kV Insulation Resistance Tester KIT w/IR3000
- Overview
- Specifications
- Summary
- Accessories
Product Highlights
Fluke 1550C Kit
- Test voltages up to 10 kV provides solutions for all applications
- CAT III 1000 V, CAT IV 600 V safety rating
- Voltage breakdown detection alerts the user that voltage is present and gives the voltage reading up to 600 V ac or dc for increased user safety
- Selectable test voltages in 50 V steps from 250 to 1000 V, and 100 V steps above 1000 V
- Measurements can be stored in up to 99 memory locations, with each location assigned a unique, user defined, label for easy recall
- Long battery life gives the user over 750 tests between charges
- Automatic calculation of Dielectric Absorption (DAR) and Polarization Index (PI) with no additional setup
- Guard system eliminates the effect of surface leakage current on high-resistance measurements
- Large digital/analog LCD for easy viewing
- Capacitance and leakage current measurement
- Ramp function for breakdown testing
- Resistance measurements up to 2TΩ
- Timer settings up to 99 minutes for timed tests
Fluke IR3000FC
- Fluke Connect IR 3000 Connector allows you to wirelessly transfer data from your existing Fluke tools to your smart phone
- Fits over the IR port of your existing Fluke tools
- Upgradeable by USB
- Immediately enables you to graph, save, and share the tool’s readings with your team from your smart phone
Each Unit Includes
Fluke 1550C Insulation Tester Kit
- Test cables with alligator clips (red, black, green)
- Infrared adapter with interface cable
- FlukeView® Forms Basic CD-ROM
- AC power cord
- IHard Canvas Carrying Case
- English manual
- User's manual on CD-ROM
- Quick reference card
- Software license agreement
- Registration card
- FlukeView® Forms installation guide
- USB-IR cable installation guide
- Certificate of Calibration
- Ruggedized Alligator Clips
- Fluke IR3000FC Fluke Connect IR 3000 Connector
Insulation resistance measurement |
Test voltage (dc) |
Range (dc) |
Accuracy (? reading) |
250 V |
< 200 kΩ
200 kΩ to 5 GΩ
5 GΩ to 50 GΩ
> 50 GΩ |
unspecified
5 %
20 %
unspecified |
500 V |
< 200 kΩ
200 kΩ to 10 GΩ
10 GΩ to 100 GΩ
> 100 GΩ |
unspecified
5 %
20 %
unspecified |
1000 V |
< 200 kΩ
200 kΩ to 20 GΩ
20 GΩ to 200 GΩ
> 200 GΩ |
unspecified
5 %
20 %
unspecified |
2500 V |
< 200 kΩ
200 kΩ to 50 GΩ
50 GΩ to 500 GΩ
> 500 GΩ |
unspecified
5 %
20 %
unspecified |
5000 V |
< 200 kΩ
200 kΩ to 100 GΩ
100 GΩ to 1 TΩ
> 1 TΩ |
unspecified
5 %
20 %
unspecified |
10000 V |
< 200 kΩ
200 kΩ to 200 GΩ
10 GΩ to 2 TΩ
> 2 TΩ |
unspecified
5 %
20 %
unspecified |
|
Bar graph range |
0 to 1 TΩ |
Insulation test voltage accuracy |
-0 %, +10 % at 1 mA load current |
Induced ac mains current rejection |
2 mA maximum |
Charging rate for capacitive load |
5 seconds per °F |
Discharge rate for capacitive load |
1.5 s/°F |
|
|
Range |
Accuracy |
Leakage current measurement |
1 nA to 2 mA |
± (5 % + 2 nA) |
Capacitance measurement |
0.01 uF to 15.00 °F |
± (15 % rdg + 0.03 °F) |
Timer |
0 to 99 minutes |
Resolution
Setting: 1 minute
Indication: 1 second |
Live circuit warning |
Warning range
30 V to 660 V ac/dc, 50/60 Hz |
Voltage accuracy
? (15 % + 2 V) |
General specifications |
Display |
75 mm x 105 mm |
Power |
12 V lead-acid rechargeable battery, Yuasa NP2.8-12 |
Charger Input (AC) |
85 V ac 50/60 Hz 20 VA |
This Class II (double insulated) instrument is supplied with a Class 1 (grounded) power cord. The protective earth terminal (ground pin) is not connected internally. The extra pin is for added plug retention only. |
Dimensions |
170 mm x 242 mm x 330 mm (6.7 in x 9.5 in x 13 in) |
Weight |
3.6 kg (7.94 lb) |
Temperature (operating) |
-20 °C to 50 °C (-4 °F to 122 °F) |
Temperature (storage) |
-20 °C to 65 °C (-4 °F to 149 °F) |
Humidity |
80 % to 31 °C decreasing linearly to 50 % at 50 °C |
Altitude |
2000 m |
Enclosure sealing |
IP40 |
Input overload protection |
1000 V ac |
Electromagnetic compatibility |
EN 61326 |
Safety compliance |
CAT III 1000 V, CAT IV 600 V |
Pollution degree |
2 |
FLUKE IR3000FC Specifications |
Battery type |
Two AA Alkaline batteries, NEDA 15A IEC LR6 |
Battery life |
6 hours of continuous transmission |
RF communications |
2.4 GHz ISM Band |
RF communication range |
20 meters |
Temperature |
Operating: -10 °C to 50 °C
Storage: -20 °C to 60 °C |
Certifications |
CSA, FCC, CE, IC |
Warranty |
Three years |
Weight |
80 g |
Size (HxWxL) |
3.2 cm x 7.6 cm x 6.4 cm (1.25 in x 3.0 in x 2.5 in) |
Micro / Milli / Meg Ohmmeters/Megohmmeter / Insulation Resistance Testers Template |
Type |
Battery |
IR Test Voltage |
1,000 V, 2,500 V, 250 V, 5,000 V, 500 V |
Maximum Insulation Resistance |
2 G Ohms |
Minimum Insulation Resistance |
200 K Ohms (0.0002 G Ohms) |
Variable Incremental Voltage |
Yes |
Display (Megohmmeter) |
Digital |
Continuity Test |
No |
Live Circuit Voltage Detection |
Yes |
Automated Test Results |
Dielectric Absorption Ratio, Other |
Power Supply |
Battery |
Timer |
Yes |
CAT Rating |
IV |
CAT Voltage |
1,000 V, 600 V |
Unique Features |
Measurements can be stored in up to 99 memory locations, with each location assigned a unique, user defined, label for easy recall. Long battery life gives the user over 750 tests between charges. Ramp function for breakdown testing. |
Warranty |
3 YEARS |
Calibration Included |
None |
Power Supply Voltage |
120V/220V Universal, Battery Powered |
Safety Approval |
CSA |
Data Logging |
Yes |
Interfaces I/O |
IR, USB |
IP Rating |
IP40 |
Product Weight |
8.2 LBS |
Battery Type |
Other |
Product Height |
6.3 IN |
Product Length |
10.6 IN |
Product Width |
10.9 IN |
ECCN Number |
3A992 |
HTS/Schedule B Number |
9030.33.0040 |
Country of Origin |
United States |
Other Information |
Display: 75 mm x 105 mm
Power: 12 V lead-acid rechargeable battery, Yuasa NP2.8-12
Charger Input (AC): 85 V ac 50/60 Hz 20 VA
|
|
Accessories
Product |
Price |
|
Fluke FVF-UG
Catalog #: 1576741
FlukeView Software
|
$184.24
|
|
Fluke TL1550EXT
Catalog #: 2032761
Extended Test Lead Set - 25 foot
|