|
|
Fluke Calibration 2271A-N-G7M
Catalog #: 4917857
Pressure Calibrator with Module, NPT,PM200-G7M,7 MPA(1000 PSI)
- Overview
- Specifications
- Summary
Product Highlights
2271A Industrial Pressure calibrator
- Calibrate a wide range of gauges and sensors with a single instrument
- Wide measurement range from -100 kPa to 20 MPa (-15 to 3000 psi)
- Removable pressure measurement modules make it easy to change or add measurement ranges
- Integrated electrical measurement module with HART communication provides a complete solution for calibrating pressure transmitters
- Built-in dual test ports enable you to connect multiple devices under test (DUTs)
- 0.02 % FS pressure measurement uncertainty
- Localized graphical user interface in choice of ten languages
PM200 Pressure Measurement Module
- Range (SI Units): 0 MPa to 7 MPa
- Range (Imperial Units): 0 psi to 1000 Psi
- 0.02% FS specification makes it ideal for calibrating or testing pressure dial gauges, lower accuracy transmitters, or pressure switches
- Rugged silicon pressure sensor design allows for faster control
- Economic price point helps facility the purchase of backup modules, making sure you are never down for calibration
Each Unit Includes
- 2271A Main Chassis
- Pressure Measurement Module, 0 MPa to 7 MPa (0 psi to 1000 psi), Gauge (PM200-G7M)
- Electrical Measurement Module
- User Manual
- 4x NPT Female Adapters (1/8, 1/4, 3/8, 1/2 )
- 4x BSP Female Adapters (1/8, 1/4, 3/8, 1/2 )
- M14 Female Adapter
- Test Lead Set
- US Power Cord
General specifications |
Power requirements |
0 V ac to 240 V ac, 47 Hz to 63 Hz |
Fuse |
T2A 250 V ac |
Max power consumption |
100 W |
Operating ambient temperature range |
15 °C to 35 °C |
Storage temperature |
-20 °C to 70 °C |
Relative humidity |
Operating: <80 % to 30 °C, <70 % to 35 °C
Storage: <95 %, non-condensing. A power stabilization period of four days may be required after extended storage at high temperature and humidity. |
Vibration |
MIL-T-28800D CLASS 3 |
Altitude (Operation) |
<2000 m |
Ingress protection |
IEC 60529: IP20 |
Safety |
IEC 61010-1, Installation Category II, Pollution degree 2 |
Warmup time |
15 minutes typical |
Weight (chassis only) |
15 kg (33.06 lbs) |
Control specifications |
Control Precision (Dynamic Mode) |
PM200-BG2.5K |
Control turndown |
10:1 (Typical) |
Low control point |
1 kPa (0.15 psi) absolute |
Fluke PM200 Modules Specification |
Model |
Range (SI Units) |
Range (Imperial Units) |
Measurement Mode 1 |
1-Year Instrumental Uncertainty % FS |
Precision Uncertainty % FS |
PM200-BG2.5K |
-2.5 kPa to 2.5 kPa |
-10 inH2O to 10 inH2O |
bi-directional gauge |
0.2 |
0.055 |
PM200-BG35K |
-35 kPa to 35 kPa |
-5 psi to 5 psi |
bi-directional gauge |
0.05 |
0.015 |
PM200-BG40K |
-40 kPa to 40 kPa |
-6 psi to 6 psi |
bi-directional gauge |
0.05 |
0.015 |
PM200-BG60K |
-60 kPa to 60 kPa |
-8.7 psi to 8.7 psi |
bi-directional gauge |
0.05 |
0.015 |
PM200-BG100K |
-100 kPa to 100 kPa |
-15 psi to 15 psi |
gauge |
0.02 |
0.01 |
PM200-A100K |
2 kPa to 100 kPa |
0.3 psi to 15 psi |
absolute |
0.1 |
0.02 |
PM200-A200K |
2 kPa to 200 kPa |
0.3 psi to 30 psi |
absolute |
0.1 |
0.02 |
PM200-BG200K |
-100 kPa to 200 kPa |
-15 psi to 30 psi |
bi-directional gauge |
0.02 |
0.01 |
PM200-BG250K |
-100 kPa to 250 kPa |
-15 psi to 36 psi |
bi-directional gauge |
0.02 |
0.01 |
PM200-G400K |
0 kPa to 400 kPa |
0 psi to 60 psi |
gauge |
0.02 |
0.01 |
PM200-G700K |
0 kPa to 700 kPa |
0 psi to 100 psi |
gauge |
0.02 |
0.01 |
PM200-G1M |
0 MPa to 1 MPa |
0 psi to 150 psi |
gauge |
0.02 |
0.01 |
PM200-G1.4M |
0 MPa to 1.4 MPa |
0 psi to 200 psi |
gauge |
0.02 |
0.01 |
PM200-G2M |
0 MPa to 2 MPa |
0 psi to 300 psi |
gauge |
0.02 |
0.01 |
PM200-G2.5M |
0 MPa to 2.5 MPa |
0 psi to 360 psi |
gauge |
0.02 |
0.01 |
PM200-G3.5M |
0 MPa to 3.5 MPa |
0 psi to 500 psi |
gauge |
0.02 |
0.01 |
PM200-G4M |
0 MPa to 4 MPa |
0 psi to 580 psi |
gauge |
0.02 |
0.01 |
PM200-G7M |
0 MPa to 7 MPa |
0 psi to 1000 psi |
gauge |
0.02 |
0.01 |
PM200-G10M |
0 MPa to 10 MPa |
0 psi to 1500 psi |
gauge |
0.02 |
0.01 |
PM200-G14M |
0 MPa to 14 MPa |
0 psi to 2000 psi |
gauge |
0.02 |
0.01 |
PM200-G20M |
0 MPa to 20 MPa |
0 psi to 3000 psi |
gauge |
0.02 |
0.01 |
Notes
- Gauge mode modules (PM200-GXXX or PM200-BGXXX) with ranges of 100 kPa (15 psi) or greater will support absolute mode measurement when used with a Barometric Reference Module.
- For temperatures from 15 °C to 18 °C and 28 °C to 35 °C, add 0.003 % FS/°C.
- Uncertainty for gauge mode modules assumes routine zeroing. Uncertainty for absolute-mode modules includes 1-year zero stability. This specification can be reduced to 0.05 % FS if the PM200 module is zeroed on a continuing basis to remove the 1-year zero stability component.
- Instrumental measurement uncertainty for gauge mode modules used in absolute mode by addition of a barometric reference module is calculated as the uncertainty of the gauge mode module plus the uncertainty of the Barometric Reference Module.
|
ECCN Number |
EAR99 |
Country of Origin |
China |
|
|
|
|