| General Specifications |
| |
Ti480 PRO |
Ti450 PRO |
| Key features |
| Detector resolution |
640 x 480 (307,200) or 1280 x 960 with SuperResolution |
320 x 240 (76,800 pixels) or 640 x 480 with SuperResolution |
| SuperResolution |
Yes, in software. Captures and combines 4x the data to create a 1280 x 960 image |
Yes, in software. Captures and combines 4x the data to create a 640 x 480 image |
| IFOV with standard lens (spatial resolution) |
0.93 mRad, D:S 1065:1 |
1.31 mRad, D:S 753:1 |
| Field of view |
34 °H x 24 °V |
24 °H x 17 °V |
| Minimum focus distance |
15 cm (approx. 6 in) |
| MultiSharp™ Focus |
Yes, focused near and far, throughout the field of view |
| LaserSharp® Auto Focus |
Yes, for consistently in-focus images. Every. Single. Time. |
| Laser distance meter |
Yes, calculates distance to the target for precisely focused images and displays distance on screen |
| Advanced manual focus |
Yes |
| Wireless connectivity |
Yes, to PC, iPhone® and iPad® (iOS 4s and later), Android™ 4.3 and up, and WiFi to LAN (where available) |
| Fluke Connect® app compatible |
Yes*, connect your camera to your smartphone, and images taken automatically upload to the Fluke Connect app for saving and sharing |
| Fluke Connect® Assets optional software |
Yes*, assign images to assets and create work orders. Easily compare measurement types in one location. |
| Fluke Connect® Instant Upload |
Yes*, connect your camera to your building’s WiFi network, and images taken automatically upload to the Fluke Connect system for viewing on your smartphone or PC |
| Fluke Connect® tool compatible |
Yes*, connects wirelessly to select Fluke Connect enabled tools and displays measurements on camera screen. |
| IR-Fusion® technology |
Yes, adds the context of the visible details to your infrared image |
| AutoBlend mode |
Min, Mid, Max IR plus full visible on camera; continously variable in software |
| Picture-In-Picture (PIP) |
Yes |
| Ruggedized touchscreen display |
3.5 inch (landscape) 640 x 480 LCD |
| Rugged, ergonomic design for one-handed use |
Yes |
| Thermal sensitivity (NETD)** |
≤ 0.05 °C at 30 °C target temp (50 mK) |
≤ 0.025 °C at 30 °C target temp (25 mK) |
| Level and span |
Smooth auto and manual scaling |
| Fast auto toggle between manual and auto modes |
Yes |
| Fast auto-rescale in manual mode |
Yes |
| Minimum span (in manual mode) |
2.0 °C (3.6 °F) |
| Minimum span (in auto mode) |
3.0 °C (5.4 °F) |
| Built-in digital camera (visible light) |
5MP |
| Frame rate |
60 Hz or 9 Hz versions |
| Laser pointer |
Yes |
| LED light (torch) |
Yes, improved output torch |
| Digital zoom |
2x and 4x |
| Data storage and image capture |
| Extensive memory options |
Removable 4 GB micro SD memory card, 4 GB internal flash memory, save to USB flash drive capability, upload to for permanent storage |
| Image capture, review, save mechanism |
One-handed image capture, review, and save capability |
| Image file formats |
Non-radiometric (.bmp) or (.jpeg) or fully-radiometric (.is2); no analysis software required for non-radiometric (.bmp, .jpg and .avi) files |
| Memory review |
Thumbnail and full screen review |
| Software |
SmartView® software—full analysis and reporting software |
| Export file formats with Fluke Connect® desktop software |
Bitmap (.bmp), GIF, JPEG, PNG, TIFF |
| Voice annotation |
60 seconds maximum recording time per image; reviewable playback on camera, optional bluetooth headset available but not required |
| IR-PhotoNotes |
Yes (5 images) |
| Text annotation |
Yes |
| Video recording |
Standard and radiometric |
| File formats video |
Non-radiometric (MPEG - encoded .AVI) and fully-radiometric (.IS3) |
| Remote display viewing |
Yes, see the live stream of the camera display on your PC, smartphone, or TV monitor. Via USB, WiFi hotspot, or WiFi network to SmartView® software on a PC; via WiFi hotspot to the Fluke Connect® app on a smartphone; or via HDMI to a TV monitor |
| Remote control operation |
Yes, through SmartView® software or Fluke Connect® mobile app |
| Auto capture (temperature and interval) |
Yes |
| Battery |
| Batteries (field-replaceable, rechargeable) |
Two lithium ion smart battery packs with five-segment LED display to show charge level |
| Battery life |
2-3 hours per battery (*Actual life varies depending on settings and usage) |
3-4 hours per battery (*Actual life varies depending on settings and usage) |
| Battery charge time |
2.5 hours to full charge |
| Battery charging system |
Two-bay battery charger or in-imager charging. Optional 12 V automotive charging adapter |
| AC operation |
AC operation with included power supply (100 V AC to 240 V AC, 50/60 Hz) |
| Power saving |
User selectable sleep and power off modes |
*Fluke Connect analysis and reporting software is available in all countries but Fluke Connect is not. Please check availability with your authorized Fluke distributor.
** Best possible |
| |
Ti480 PRO |
Ti450 PRO |
| Temperature measurement |
| Temperature measurement range (not calibrated below -10 °C) |
≤ -10 °C to +1000 °C (-14 °F to 1832 °F) |
-10 °C to 1500 °C (14 °F to 2732 °F) |
| Accuracy |
± 2 °C or 2 % (at 25 °C nominal, whichever is greater) |
| On-screen emissivity correction |
Yes (both value and table) |
| On-screen reflected background temperature compensation |
Yes |
| On-screen transmission correction |
Yes |
| Live line marker |
Yes |
| Color palettes |
| Standard palettes |
9: Rainbow, Ironbow, Blue-Red, High Contrast, Amber, Amber Inverted, Hot Metal, Grayscale, Grayscale Inverted |
| Ultra Contrast palettes |
9: Rainbow, Ironbow, Blue-Red, High Contrast, Amber, Amber Inverted, Hot Metal, Grayscale, Grayscale Inverted |
| Specification |
| Color alarms (temperature alarms) |
High temperature, low temperature, and isotherms (within range) |
| Infrared spectral band |
7.5 μm to 14 μm (long wave |
| Operating temperature |
-10 °C to +50 °C (14 °F to 122 °F) |
| Storage temperature |
-20 °C to +50 °C (-4 °F to 122 °F) without batteries |
| Relative humidity |
10 % to 95 % non-condensing |
| Center-point temperature measurement |
Yes |
| Spot temperature |
Hot and cold spot markers |
| User-definable spot markers |
3 user-definable spot markers |
| Center box |
Up to 3 expandable-contractible measurement box with MIN-MAX-AVG temp display |
| Safety |
IEC 61010-1: Overvoltage category II, Pollution Degree 2 |
| Electromagnetic compatibility |
IEC 61326-1: Basic EM environment. CISPR 11: Group 1, Class A |
| Australian RCM |
IEC 61326-1 |
| US FCC |
CFR 47, Part 15 Subpart C Sections 15.207, 15.209, 15.249 |
| Vibration |
0.03 g2/Hz (3.8 g), 2.5 g IEC 68-2-6 |
| Shock |
25 g, IEC 68-2-29 |
| Drop |
Engineered to withstand 2 meter (6.5 feet) drop with standard lens |
| Size (H x W x L) |
27.7 cm x 12.2 cm x 16.7 cm (10.9 in x 4.8 in x 6.5 in) |
| Weight (battery included |
1.04 kg (2.3 lb) |
| Enclosure rating |
IEC 60529: IP54 (protected against dust, limited ingress; protection against water spray from all directions) |
| Warranty |
Two-years (standard), extended warranties are available |
| Recommended calibration cycle |
Two-years (assumes normal operation and normal aging) |
| Supported languages |
Czech, Dutch, English, Finnish, French, German, Hungarian, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, and Turkish |
| RoHS compliant |
Yes |