Megger MIT410/2
Catalog #: 1004-735
50V/100V/250V/500V/1000V 600V CATIV Insulation and Continuity Tester + PI, DAR
- Overview
- Specifications
- Summary
- Accessories
Product Highlights
- MIT410/2 - 50 V, 100 V, 250 V, 500 V, 1000 V insulation tester + PI & DAR + CAT IV 600 V
- Stabilized insulation test voltage (New)
- Single range, faster continuity testing from 0.01 O to 1 MO (New)
- 600 V Trms AC and DC voltage measurement
- Live circuit detection and protection
- User variable insulation test voltage from 100V to 1000V (depending on model)
- Test result storage and Bluetooth® downloading, (depending on model)
- Rechargeable options for mains and car charging (depending on model)
- CAT IV 600 V & IP54
Each Unit Includes
-
- Hard carry case
- Red/black test lead set with clips
- 6 AA (LR6) batteries fitted
- Warranty card
- Owners CD manual
- Quick start guide
- SP5 remote switched probe
- Factory (non-NIST) Calibration Certificate
*All quoted accuracies are at +20° C. |
Insulation Nominal test voltages |
50 V, 100 V, 250 V, 500 V, 1000 V |
Insulation resistance range |
100 GΩ |
Range Full Scale Accuracy |
1000 volts ±3% ±2 digits ±0.2% per GΩ
500 volts ±3% ±2 digits ±0.4% per GΩ
250 volts ±3% ±2 digits ±0.8% per GΩ
100 volts ±3% ±2 digits ±2.0% per GΩ
50 volts ±3% ±2 digits ±4.0% per GΩ |
Analog range |
1 GΩ full scale |
Short Circuit Current |
2 mA +0% -50% |
Terminal voltage |
-0% +20% ±1 V |
Test Current on load |
1 mA at min. pass value of insulation specified in BS7671, HD384and IEC364, 2 mA max. |
EN61557 Operating range |
0.10 M½ to 1.00 GΩ |
Leakage Current |
10% ±3 digits |
Voltage display |
3% ±3 digits ±0.5% of rated voltage |
Polarization Index (PI) |
10 min/1 minute ratio |
Dielectric Absorption Ratio (DAR) |
60 sec/30 sec ratio |
Notes |
(1) All ranges measure from 0.00 M½ upwards.
(2) Above specifications only apply when high quality silicone leadsare being used. |
Continuity |
Measurement |
0.01 ½ to 99.9 ½ (0 to 100 ½ on analog scale) |
Accuracy |
±3% ±2 digits (0 to 100 Ω) |
Open circuit voltage |
5 V ±1 V |
Test current |
200 mA (–0 mA +20 mA)
(0.01 ½ to 9.99 Ω)
20mA (±1 mA )
(10.0 ½ to 99.9 Ω) |
Zero offset at probe tips |
0.10Ω typical |
Lead resistance zeroing |
Up to 9.00 Ω |
Buzzer |
Variable limit 1Ω, 2Ω, 5Ω,10Ω, 20Ω |
Resistance |
Measurement |
0.01 kΩ to 1000 kΩ
(0 to 1 MΩ on analog scale) |
Accuracy |
±3% ±2 digits
Open circuit voltage 5 V ±1 V
Short circuit current 20 µA ± 5 µA |
Voltage range |
0 to 600 V d.c. ±2% ±2 digits
10 mV to 600 V TRMS sinusoidal (40 to 400 Hz) ±2% ±2 digits
0 to 1000 V on Analog scale
Unspecified input level 0 - 10 mV (40 to 400 Hz)
For non-sinusoidal waveforms additional specification apply:
±3% ±2 digits 101 mV to 600 V TRMS and ±8% ±2 digits 10 mV to 100 mV TRMS |
Default Voltmeter |
Operates at >25 V a.c. or d.c. on any range except OFF |
Frequency |
40 - 450 Hz (40 Hz - 99.9 Hz)
±0.5% ±1 digit (100 Hz to450 Hz) |
Result storage |
Capacity |
>1000 test results |
Download |
Bluetooth wireless |
Bluetooth Class |
Class II |
Range |
up to 10 m |
Power |
Power Supply |
5 x 1.5 V cells type IEC LR6 (AA, MN1500, HP7, AM3 R6HP) Alkaline NiMH rechargeable cells may be used.
Battery life: 2200 insulation tests with duty cycle of 5 sec ON /55 sec OFF @ 1000 V into 1 MΩ |
Dimensions |
Instrument |
220 x 92 x 50 mm (8.66 in. x 3.63 in. x 1.97 in.) |
Instrument and case |
456 x 178 x 89 mm (18 in. x 7 in. x 3.5 in.) |
Weight |
Instrument only |
590 gms (20.73 oz.), 775 gms (27.22 oz.) with boot |
Instrument and case |
1.75kg (3.86 lb) |
Fuse |
Use only a 500 mA (FF) 1000 V 32 x 6 mm ceramic fuse of highbreaking capacity HBC 50 kA minimum. Glass fuses MUST NOT be fitted. |
Safety Protection |
The instruments meet EN 61010-1 (1995) to 600 V phase to earth, Category IV. Refer to safety warnings supplied. |
E.M.C. |
In accordance with IEC 61326 including amendment No.1 |
Temperature effects |
Temperature coefficient |
<0.1&Omega per °C up to 1 G&Omega |
Environmental |
Operating range |
-10 to +55° C |
Operating humidity |
90% RH at 40° C max. |
Storage temperature range |
-25 to +70° C |
Calibration Temperature |
+20° C |
Maximum altitude |
2000 m |
Dust and water protection |
IP54 Protected against dust and splashing water |
Micro / Milli / Meg Ohmmeters/Megohmmeter / Insulation Resistance Testers Template |
Type |
Battery |
IR Test Voltage |
1,000 V, 100 V, 250 V, 50 V, 500 V |
Maximum Insulation Resistance |
200 G Ohms |
Minimum Insulation Resistance |
0.01 Ohms (0.00000000001 G Ohms) |
Variable Incremental Voltage |
Yes |
Display (Megohmmeter) |
Digital |
Continuity Test |
Yes |
Live Circuit Voltage Detection |
Yes |
Automated Test Results |
Dielectric Absorption Ratio, Dielectric Discharge, Leakage Current, Other, Step Voltage |
Power Supply |
Battery |
Timer |
Yes |
CAT Rating |
IV |
CAT Voltage |
600 V |
Unique Features |
True RMS voltage measurement
– allows accurate voltage
measurement on noisy lines
Auto ranging voltage measurement
– automatically adjusts
range from millivolts to 600 V AC or DC, eliminating the
need to keep changing ranges
Live circuit warning
– automatically warns of contact to a
live circuit, voltage is displayed and testing is inhibited
Auto fuse warning
– warns of fuse failure automatically.
No need to test the fuse manually.
Buzzer select button
– enable or disable buzzer as required
with resistance also displayed on the screen |
Warranty |
3 YEARS |
Warranty Details |
Years 2 and 3 require free registration of the unit. |
Calibration Included |
Factory Calibration |
Power Supply Voltage |
Battery Powered |
Data Logging |
No |
IP Rating |
IP54 |
Product Weight |
27.22 OUNCES (1.70 LBS) |
Battery Type |
AA |
Product Height |
2.32 IN |
Product Length |
9.00 IN |
Product Width |
4.25 IN |
Shipping Weight |
32 OUNCES (2 LBS) |
ECCN Number |
EAR99 |
Country of Origin |
United Kingdom |
Shipping Height |
5 IN |
Shipping Length |
20 IN |
Shipping Width |
9 IN |
|
Accessories
Product |
Price |
|
Megger 1007-157
Catalog #: 1007-157
SP5 Remote Switch Probe CATIV 600V
|
$215.23
|
|
Megger 1007-160
Catalog #: 1007-160
Carry and Pouch Test
|
$122.23
|
|
Megger 1007-464
Catalog #: 1007-464
Mains Charger Kit (MIT400/2 series Mk 2)
|
$153.23
|
|
Megger 1007-637
Catalog #: 1007-637
Replacement lead set 2.50 kV (Red/Black/Blue)
|
$230.23
|
|
Megger 1007-780
Catalog #: 1007-780
Lead Set Unfused (Red/Black/Green) for MIT481/2 and MIT485/2
|
$230.23
|
|
Megger 1007-781
Catalog #: 1007-781
Replacement lead set unfused (R/Blk/G)
|
$230.23
|
|
Megger 1007-887
Catalog #: 1007-887
For MIT400/2 Series Test and Carry Pouch
|
$230.23
|
|
|
|