Our search by product feature is currently under construction. Please search by manufacturer or using the site search bar. We apologize for the inconvenience. Should you have any questions please feel free to contact us at sales@usamultimeters.com or by calling 888-315-6773
Fluke 1732/EUS
Catalog #: 4706548
Three-Phase Electrical Energy Logger (EU/US Version)

  • Overview
  • Specifications
  • Summary
  • Accessories
  • Current Clamps*Adapters

Product Highlights

  • EU/US Version Three-Phase Electrical Energy Logger (includes current probes)
  • Energy studies: Full range of electrical power and energy parameters
  • Load studies: Simple current only logging for load sizing
  • Comprehensive logging: More than 20 separate logging sessions can be stored on the instruments
  • Optimized user interface: Quick, guided, graphical setup ensures you’re capturing the right data every time, and the intelligent verification function indicates correct connections have been made, reducing user uncertainty
  • Bright, color touch screen: Perform convenient in-the-field analysis and data checks with full graphical display
  • Optimized user interface: Capture the right data every time with quick, guided, graphical setup and reduce uncertainty about your connections with the intelligent verification function
  • Complete “in-the-field” setup through the front panel or Fluke Connect: No need to return to the workshop for download and setup or to take a computer to the electrical panel
  • Energy Analyze Plus application software: Download and analyze every detail of energy consumption with our automated reporting
  • Measure all three phases: With included 3 flexible current probes
  • Fully integrated logging: Connect other Fluke Connect devices to the Fluke 1732/1734 to simultaneously log up to two other measurement parameters, virtually any parameter available on a Fluke Connect wireless digital multimeter or module

Each Unit Includes

  • (1) Three-Phase Electrical Energy Logger (EU/US Version)
  • (1) Voltage Test Lead
  • (1) Dolphin Clip (Black)
  • (3) iFlex Flexible current probe (1500A, 12in)
  • (4) Color-coded Wire Clips
  • (1) Power Cord
  • (2) Red and Black Test lead with stackable plugs (10cm, 3.9in) Red and Black
  • (2) Red and Black Test lead with stackable plugs (1.5m ,5ft)
  • (1) DC Power Cable
  • (1) USB Cable A (Mini-USB)
  • (1) Soft Case
  • (1) Input Connector Decal*
  • (1) Documentation Info Pack
    • Quick Reference Card
    • Safety Information
    • Battery Pack Safety Information
    • iFlex Probe Safety Information
    • i40s-EL Current Clamp Safety Information
  • (1) 4GB USB Flash Drive (includes User’s Manual)
  • ISO 9001 - Statement of Calibration Practices (W/Data)

*The power cord and input connector decal are country-specific and vary according to the order destination

Accuracy
Parameter Range Max. Resolution Intrinsic accuracy at reference conditions
(% of reading + % of full scale)
Voltage: 1000 V 0.1 V ± (0.2 % + 0.01 %)
Current: i17xx-flex 1500 12” 150 A
1500 A
0.1 A
1 A
± (1 % + 0.02 %)
± (1 % + 0.02 %)
i17xx-flex 3000 24” 300 A
3000 A
1 A
10 A
± (1 % + 0.03 %)
± (1 % + 0.03 %)
i17xx-flex 6000 36” 600 A
6000 A
1 A
10 A
± (1.5 % + 0.03 %)
± (1.5 % + 0.03 %)
i40s-EL clamp 4 A
40 A
1 mA
10 mA
± (0.7 % + 0.02 %)
± (0.7 % + 0.02 %)
Frequency: 42.5 Hz to 69 Hz 0.01 Hz ± (0.1 %)
Aux input: ± 10 V dc 0.1 mV ± (0.2 % + 0.02 %)
Voltage min/max: 1000 V 0.1 V ± (1 % + 0.1 %)
Current min/max: defined by accessory defined by accessory ± (5 % + 0.2 %)
THD on voltage: 1000% 0.10% ± 0.5
THD on current: 1000% 0.10% ± 0.5

 

Intrinsic uncertainty ± (% of reading + % of range)1
Parameter Influence quantity iFlex1500-12
150A/1500A
iFlex3000-24
300A/3000A
iFlex6000-36
600/6000A
i40s-EL
4A/40A
Active Power P
Active Energy Ea
PF ≥ 0.99 1.2 % + 0.005 % 1.2 % + 0.0075 % 1.7 % + 0.0075 % 1.2 % + 0.005 %
Apparent Power S
Apparent Energy Eap
0 ≤ PF ≤ 1 1.2 % + 0.005 % 1.2 % + 0.0075 % 1.7 % + 0.0075 % 1.2 % + 0.005 %
Reactive Power Q
Reactive Energy Er
0 ≤ PF ≤ 1 2.5 % of measured apparent power
Additional uncertainty in % of range1 V P-N   > 250 V 0.015 % 0.0225 % 0.0225 % 0.015 %

1Range = 1000 V x Irange
Reference conditions:
•  Environmental: 23°C ± 5°C, instrument operating for at least 30 minutes, no external electrical/magnetic field, RH <65 %
•  Input conditions: Cosϕ/PF=1, Sinusoidal signal f=50 Hz/60 Hz, power supply 120 V/230 V ±10 %.
•  Current and power specifications: Input voltage 1 ph: 120 V/230 V or 3 ph wye/delta: 230 V/400 V Input current: I > 10 % of Irange
•  Primary conductor of clamps or Rogowski coil in center position
•  Temperature coefficient: Add 0.1 x specified accuracy for each degree C above 28°C or below 18°C
 

Electrical specifications
Power supply
Voltage range: 100 V to 500 V using safety plug input when powering from the measurement circuit
100 V to 240 V using standard power cord (IEC 60320 C7)
Power consumption: Maximum 50 VA (max. 15 VA when powered using IEC 60320 input)
Efficiency: ≥ 68.2 % (in accordance with energy efficiency regulations)
Maximum no-load consumption: < 0.3 W only when powered using IEC 60320 input
Mains power frequency: 50/60 Hz ± 15 %
Battery: Li-ion 3.7 V, 9.25 Wh, customer-replaceable
On-battery runtime: Four hours in standard operating mode, up to 5.5 hours in power saving mode
Charging time: < 6 hours
Data acquisition
Resolution: 16-bit synchronous sampling
Sampling frequency: 10.24 kHz at 50/60 Hz, synchronized to mains frequency
Input signal frequency: 50/60 Hz (42.5 to 69 Hz)
Circuit types: 1-ϕ, 1-ϕ IT, split phase, 3-ϕ delta, 3-ϕ wye, 3-ϕ wye IT, 3-ϕ wye balanced, 3-ϕ Aron/Blondel (2-element delta), 3-ϕ delta open leg, currents only (load studies)
Data storage: Internal flash memory (not user replaceable)
Memory size: Typical 10 logging sessions of 8 weeks with 1-minute intervals1
Basic interval
Measured parameters: Voltage, current, aux, frequency, THD V, THD A, power, power factor, fundamental power, DPF, energy
Averaging interval: User selectable: 1 sec, 5 sec, 10 sec, 30 sec, 1 min, 5 min, 10 min, 15 min, 30 min
Averaging time min/max values: Voltage, Current: Full cycle RMS updated every half cycle Aux, Power: 200ms
Demand Interval (Energy Meter Mode)
Measured parameters: Energy (Wh, varh, VAh), PF, maximum demand, cost of energy
Interval: User selectable: 5 min, 10 min, 15 min, 20 min, 30 min, off
Standards compliance
Power: IEEE 1459
Interfaces
USB-A: File transfer via USB flash drive, firmware updates, max. supply current: 120 mA
WiFi: File transfer and remote control via direct connection or WiFi infrastructure
Bluetooth: Read auxiliary measurement data from Fluke Connect® 3000 series modules (requires 1734, or 1732 upgrade option)
USB-mini: Data download device to PC
Voltage inputs
Number of inputs: 4 (3 phases and neutral)
Maximum input voltage: 1000 Vrms, CF 1.7
Input impedance: 10 MΩ
Bandwidth: 42.5 Hz - 3.5 kHz
Scaling: 1:1 and variable
Measurement category: 1000 V CAT III/600 V CAT IV
Current inputs
Number of inputs: 3, mode selected automatically for attached sensor
Input voltage: Clamp input: 500 mVrms/50 mVrms; CF 2.8
Rogowski coil input: 150 mVrms/15 mVrms at 50 Hz, 180 mVrms/18 mVrms at 60 Hz; CF 4; all at nominal probe range
Range: 1 A to 150 A/10 A to 1500 A with thin flexible current probe i17XX-flex1500 12”
3 A to 300 A/30 A to 3000 A with thin flexible current probe i17XX-flex3000 24”
6 A to 600 A/60 A to 6000 A with thin flexible current probe i17XX-flex6000 36”
40 mA to 4 A/0.4 A to 40 A with 40 A clamp i40s-EL
Bandwidth: 42.5 Hz - 3.5 kHz
Scaling: 1:1 and variable
Auxiliary inputs
Number of inputs: 2
Input range: 0 to ± 10 V dc, 1 reading/s
Scale factor: Format: mx + b (gain and offset) user configurable
Displayed units: User configurable (7 characters, for example, °C, psi, or m/s)
Wireless connection
Number of inputs: 2
Supported modules: Fluke Connect ®  3000 series
Acquisition: 1 reading/s
Environmental specifications
Operating temperature: -10 °C to +50 °C (14 °F to 122 °F)
Storage temperature: -20 °C to +60 °C (−4 °F to 140 °F), with battery: -20 °C to +50 °C (−4 °F to 122 °F)
Operating humidity: 10 °C to 30 °C (50 °F to 86 °F) max. 95 % RH
30 °C to 40 °C (86 °F to 104 °F) max. 75 % RH
40 °C to 50 °C (104 °F to 122 °F) max. 45 % RH
Operating altitude: 2000 m (up to 4000 m derate to 1000 V CAT II/600 V CAT III/300 V CAT IV)
Storage altitude: 12,000 m
Enclosure: IP50 in accordance with EN60529
Vibration: MIL-T-28800E, Type 3, Class III, Style B
Safety: IEC 61010-1
IEC Mains Input: Overvoltage Category II, Pollution Degree 2
Voltage Terminals: Overvoltage Category IV, Pollution Degree 2
IEC 61010-2-031: CAT IV 600 V/CAT III 1000 V
Electromagnetic compatibility (EMC): EN 61326-1: Industrial CISPR 11: Group 1, Class A
Korea (KCC): Class A Equipment (industrial broadcasting and communication equipment)
USA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103
Temperature coefficient: 0.1 x accuracy specification/°C
General specifications
Color LCD display: 4.3-inch active matrix TFT, 480 pixels x 272 pixels, resistive touch panel
Warranty: Instrument and power supply: two-years (battery not included)
Accessories: one-year
Calibration cycle: two-years
Dimensions: Instrument: 19.8 cm x 16.7 cm x 5.5 cm (7.8 in x 6.6 in x 2.2 in)
Power supply: 13.0 cm x 13.0 cm x 4.5 cm (5.1 in x 5.1 in x 1.8 in)
Instrument with power supply attached: 19.8 cm x 16.7 cm x 9 cm (7.8 in x 6.6 in x 3.5 in)
Weight: Instrument: 1.1 kg (2.5 lb)
Power supply: 400 g (0.9 lb)
Tamper protection: Kensington lock slot
Input(power loggers) Single Phase, Three Phase
Type(Power loggers) Digital, Portable Hand Held
Maximum Current AC 6000 A 
Maximum Voltage AC 1000 V
True RMS Yes
Power Quality No
Current Input Channels 3
Voltage Input Channels 4
Measurement Frequency 50 Hz, 60 Hz
Display (Energy Management) Digital, Graphical
Transient Capture No
Displays Waveform No
Energy Yes
Phasor Diagrams Yes
Power Factor (Power Quality) Yes
Harmonics No
Total Harmonic Distortion Yes
Current Clamps Included Yes 
Blue Tooth Compatable No
CAT Rating IV
CAT Voltage Rating (V) 600V
 
Unique Features Circuit types: 1-φ, 1-φ IT, Split phase, 3-φ delta, 3-φ wye, 3-φ wye IT, 3-φ wye balanced, 3-φ Aron/Blondel (2-element delta), 3-φ delta open leg, Currents only (load studies)

Measured parameters Voltage, current, aux, frequency, THD V, THD A, power, power factor, fundamental power, DPF, energy
Averaging interval User selectable: 1 sec, 5 sec, 10 sec, 30 sec, 1 min, 5 min, 10 min, 15 min, 30 min
Averaging time min/max values Voltage, Current: Full cycle RMS updated every half cycle Aux, Power: 200ms
Demand Interval (Energy Meter Mode)
Measured parameters Energy (Wh, varh, VAh), PF, maximum demand, cost of energy
Interval User selectable: 5 min, 10 min, 15 min, 20 min, 30 min, off
Warranty 2 YEARS
Warranty Details Instrument and power supply: Two-years (battery not included)
Accessories: one-year
Calibration cycle: two-years
Calibration Included None
Power Supply Voltage 120V 50/60 Hz
Safety Approval CE
Data Logging Yes
Interfaces I/O USB Host, Wifi
Storage Internal Memory
IP Rating IP50
Battery Type Li-ion
MEMBER PRICE: INACTIVE
List price:   $5,004.24
Notify me when price changes $

Related products

Accessories

Current Clamps*Adapters

Recently viewed products

  • Catalog #: 4706548 Three-Phase Electrical Energy Logger (EU/US Version)

    $5,004.24
We Ship Worldwide
Australia
Write us quote request in any language and then immediately translate it to English on our site.
Brazil
Envíenos su solicitud en cualquier idioma, que luego se traducen automáticamente en Inglés en nuestro sitio web.
Chile
Envíenos su solicitud en cualquier idioma, que luego se traducen automáticamente en Inglés en nuestro sitio web.
China
您的要求发送给我们以任何语言,它会自动翻译成英文在我们的网站。
France
Envoyez-nous votre demande dans n'importe quelle langue, qui seront ensuite automatiquement traduites en anglais sur notre site.
Germany
Schreiben Sie uns Ihre Anfrage in jeder beliebigen Sprache, diese wird dann auf unserer Website automatisch ins englische übersetzt.
India
हमें किसी भी भाषा में आपके अनुरोध है, जो स्वचालित रूप से हमारी वेबसाइट पर अंग्रेजी में अनुवाद हो जाएगा भेजें.
Italy
Inviaci la tua richiesta in qualsiasi lingua, che sarà automaticamente tradotto in inglese sul nostro sito web.
Japan
任意の言語で、その後は自動的に英語に当社のウェブサイト上に翻訳されますあなたのリクエストを送ってください。
Mexico
Envíenos su solicitud en cualquier idioma, que luego se traducen automáticamente en Inglés en nuestro sitio web.
Norway
Send oss din forespørsel på alle språk, som deretter automatisk oversatt til engelsk på våre nettsider.
Philippines
Ipadala sa amin ang inyong kahilingan sa kahit anong wika, na awtomatikong masasalin sa Ingles sa aming website.
Portugal
Envíenos su solicitud en cualquier idioma, que luego se traducen automáticamente en Inglés en nuestro sitio web.
Russian Federation
Отправьте нам свой запрос на любом языке, который будет автоматически переведен на английский на нашем сайте.
Spain
Envíenos su solicitud en cualquier idioma, que luego se traducen automáticamente en Inglés en nuestro sitio web.
United Kingdom
Write us quote request in any language and then immediately translate it to English on our site.
Quote Request
Portuguese Spanish German Hindi Italian Russian
English
Write us quote request in any language and then immediately translate it to English on our site
We Accept Payments
Usamultimeters.com BBB Business Review
Copyright © 2008-2024 usamultimeters.com All Rights Reserved
Products Manufactures Quote Request Resources Cart