				Amprobe ACDC-100 TRMS
                
                
                
 			 
            
			
				Catalog #: 2740465
 600V/800A AC/100A DC TRMS AC/DC Clamp Meter with Capacitance and Resistance
			 
			 
              
            
                
                    - Overview
 
                    - Specifications
 
                    - Summary
 
                    
                    
                    
                 
                	
                    
				        
                        Product Highlights
    - True-rms
 
     
    - Measures AC current to 800A and DC current to 1000A,      AC/DC voltage to 600V, plus capacitance, and resistance
 
     
    - Continuity beeper quickly identifies shorts and opens
 
     
    - Relative zero mode displays the difference between the      actual reading and a stored reference value and may be used with any      function or range
 
     
    - Data hold freezes the reading on the display for      further analysis
 
     
    - Diode test quickly finds voltage drops
 
     
    - MAX capture function measures inrush current (30 mS      response)
 
     
    - Combines user friendly features such as a large, easy      to read backlit digital display, auto power-off to conserve battery life,      and a "third hand" test probe holder
 
     
    - Rubber over-molded case absorbs shock and provides      built-in probe storage
 
     
    - Accommodates conductors up to 2.0" (50mm) in      diameter
 
     
    - CAT III, 600V rated
 
 
                        Each Unit Includes
    - 1 - Deluxe carrying case
 
    - 1 - test leads
 
    - 1 - batteries (installed)
 
    - 1 - users manual
 
 
                            
                    
                          
    
        
            | General Specifications | 
         
        
            | Display | 
            3-3/4 digits 4000 counts LCD display | 
         
        
            | Update Rate | 
            3 per second nominal | 
         
        
            | Polarity | 
            Automatic | 
         
        
            | Low Battery | 
            Below approx. 2.4V | 
         
        
            | Operating Temperature | 
            0C to 40C | 
         
        
            | Relative Humidity | 
            Maximum relative humidity 80% for temperature up to 31C decreasing linearly to 50% relative humidity at 40C | 
         
        
            | Altitude | 
            Operating below 2000m | 
         
        
            | Storage Temperature | 
            -20C to 60C, < 80% R.H. (with battery removed) | 
         
        
            | Temperature Coefficient | 
            nominal 0.15 x (specified accuracy)/ C @(0C -18C or 28C -40C), or otherwise specified | 
         
        
            | Sensing | 
            True RMS | 
         
        
            | Safety | 
            Meets EN61010-1:2001; IEC61010-2-032(2002), EN61010-2-032(2002), UL61010B-2-032(2003) Category III 600 Volts AC & DC. | 
         
        
            | Transient protection | 
            6.5kV (1.2/50μs surge) for all models | 
         
        
            | Pollution degree | 
            2 | 
         
        
            | E.M.C. | 
            Meets EN61326-1 | 
         
        
            | Overload Protections | 
         
        
            | Clamp-on jaws | 
            DC 1000A or AC 800A rms continuous + & COM terminals (all functions) : 600VDC/VAC rms | 
         
        
            | Power Supply | 
            standard 1.5V AAA Size (NEDA 24G or IEC R03) battery X 2; or 1.5V AAA Size (NEDA 24A or IEC LR03) alkaline battery X 2 | 
         
        
            | Power Consumption | 
            typical 11mA for ACA/DCA and 2.9mA for other functions | 
         
        
            | APO Timing | 
            Idle for 30 minutes | 
         
        
            | APO Consumption | 
            typical 190μA | 
         
        
            | Dimension | 
            L227mm X W78mm X H40mm | 
         
        
            | Weight | 
            290 gm approx | 
         
        
            | Jaw opening & Conductor diameter | 
            50mm max | 
         
    
 
    
        
            | Function | 
            Range | 
            Accuracy | 
         
        
            | Electrical Specifications | 
            Accuracy is ±(% reading digits + number of digits) or otherwise specified, at 23? ± 5? & less than 75% R.H. | 
         
        
            | DC Voltage | 
         
        
            |   | 
            400.0 mV | 
            0.3% + 3d | 
         
        
            |   | 
            4.000V, 40.00V, 400.0V | 
            0.5% + 3d | 
         
        
            |   | 
            600V | 
            1.0% + 4d | 
         
        
            | NMRR : | 
            >50dB @ 50/60Hz | 
              | 
         
        
            | CMRR : | 
            >120dB @ DC, 50/60Hz, Rs=1kΩ | 
              | 
         
        
            | Input Impedance : | 
            10MΩ, 30pF nominal (1000MΩ for 400.0mV range) | 
              | 
         
        
            | AC Voltage | 
         
        
            | 50Hz ~ 500Hz | 
            400.0mV 1) | 
            4.0% + 4d | 
         
        
            | 50Hz ~ 60Hz | 
            4.000V, 40.00V, 400.0V | 
            1.0% + 4d | 
         
        
            | 60Hz ~ 500Hz | 
            4.000V, 40.00V, 400.0V | 
            1.5% + 4d | 
         
        
            | 50Hz ~ 500Hz | 
            600V | 
            2.0% + 4d | 
         
        
            | CMRR : | 
            >60dB @ DC to 60Hz, Rs=1kΩ | 
              | 
         
        
            | Input Impedance: | 
            10MΩ, 30pF nominal | 
              | 
         
        
            | ACDC-100 TRMS Crest Factor: | 
            < 1.6 : 1 at full scale & < 3.2 : 1 at half scale | 
              | 
         
        
            | 1) Selection by RANGE button manually, and is specified AC 60mV and up | 
         
        
            | Resistance | 
         
        
            |   | 
            400.0Ω | 
            0.8% + 6d | 
         
        
            |   | 
            4.000kΩ, 40.00kΩ, 400.0kΩ | 
            0.6% + 4d | 
         
        
            |   | 
            4.000MΩ | 
            1.0% + 4d | 
         
        
            |   | 
            40.00MΩ | 
            2.0% + 4d | 
         
        
            | Open Circuit Voltage : | 
            0.4VDC typical | 
              | 
         
        
            | Audible Continuity Tester | 
         
        
            | Open Circuit Voltage: | 
            0.4VDC typical | 
              | 
         
        
            | Range: 400.0Ω; Accuracy: | 
            1.5% + 6d | 
              | 
         
        
            | Audible threshold: | 
            between 10Ω and 120Ω. | 
              | 
         
        
            | Diode Tester | 
         
        
            | Open Circuit Voltage | 
            Test Current (Typical) | 
              | 
         
        
            | < 1.6 VDC | 
            0.4mA | 
              | 
         
        
            | Capacitance | 
         
        
            |   | 
            500.0nF, 5.000μF, 50.00μF, 
            500.0μF, 3000μF 1) | 
            3.5% + 6d2) 3) | 
         
        
            1) Additional 50.00nF range accuracy is not specified 
            2) Accuracies with film capacitor or better 
            3) Specified with battery voltage above 2.8V (approximately half full battery). Accuracy decreases gradually to 12% at low battery 
            warning voltage of approximately 2.4V | 
         
        
            | DC Current (Clamp-on) | 
         
        
            | 400.0A | 
            0.0A ~ 400.0A | 
            1.5% + 4d 1) 2) | 
         
        
            | 1000A | 
            400A ~ 800A | 
            1.5% + 4d 1) 2) | 
         
        
            |   | 
            800A ~ 900A | 
            2.0% + 4d 1) 2) | 
         
        
            |   | 
            900A ~ 1000A | 
            5.0% + 30d 1) 2) | 
         
        
            1) Induced error from adjacent current-carrying conductor: < 0.01A/A 
            2) Δ Zero mode must be applied to zero the unit before measurement to ensure accuracy. This is particularly important below 20A. | 
         
        
            | AC Current (Clamp-on) | 
         
        
            | 400.0A | 
              | 
              | 
         
        
            |   | 
            15Hz ~ 40Hz | 
            2.0% + 5d 1) 2) 3) | 
         
        
            |   | 
            40Hz ~ 200Hz | 
            1.5% + 5d 1) 2) | 
         
        
            |   | 
            200Hz ~ 400Hz @ <50A 4) | 
            1.5% + 5d 1) 2) | 
         
        
            |   | 
            400Hz ~ 1kHz @ <50A 4) | 
            2.0% + 5d 1) 2) | 
         
        
            | 800A | 
              | 
              | 
         
        
            |   | 
            15Hz ~ 40Hz @ 400A ~ 600A | 
            2.0% + 5d 1) 2) 3) | 
         
        
            |   | 
            40Hz ~ 100Hz @ 400A ~ 600A | 
            1.5% + 4d 1) 2) | 
         
        
            |   | 
            15Hz ~ 60Hz @ 600A ~ 800A | 
            5.0% + 30d 1) 2) | 
         
        
            1) Induced error from adjacent current-carrying conductor: < 0.01A/A 
            2) ACDC-100 TRMS crest Factor: < 1.6 : 1 at full scale & < 3.2 : 1 at half scale 
            3) 4.0% + 5d for ACDC-100 TRMS 
            4) Accuracy is specified at <50A in this frequency bandwidth due to limited calibrator output capability for testing | 
         
    
 
                     
                      
    
        
            | Clamp Meters/Clamp Meters Template | 
         
        
            | Type | 
            Standard Style | 
         
        
            | True RMS | 
            Yes | 
         
        
            | Maximum Current AC | 
            800 A | 
         
        
            | Minimum Current AC | 
            0.1 A (100 mA) | 
         
        
            | Maximum Current DC | 
            1000 A | 
         
        
            | Minimum Current DC | 
            0 A (0 mA) | 
         
        
            | Maximum Voltage AC | 
            600 V | 
         
        
            | Minimum Voltage AC | 
            0.1 mV | 
         
        
            | Maximum Voltage DC | 
            600 V | 
         
        
            | Minimum Voltage DC | 
            0.1 mV | 
         
        
            | Basic Voltage Accuracy | 
            ACV: ± 2% Rdg + 4D; DCV: ± 1% Rdg + 4D | 
         
        
            | Digits Display | 
            3.75 | 
         
        
            | Counts | 
            4000 . | 
         
        
            | Resolution AC Volts | 
            0.1 mV (0.0001 V) | 
         
        
            | Resolution DC Volts | 
            0.1 mV (0.0001 V) | 
         
        
            | Resolution AC Current | 
            0.1 A | 
         
        
            | Resolution DC Current | 
            0 A | 
         
        
            | Maximum Conductor Size | 
            2 IN | 
         
        
            | Auto Ranging/Manual | 
            Both | 
         
        
            | Auto Power Off | 
            Yes | 
         
        
            | Detachable Jaw | 
            No | 
         
        
            | Rotating Jaw / Swivel | 
            No | 
         
        
            | Peak Hold | 
            No | 
         
        
            | Min/Max | 
            No | 
         
        
            | In-Rush Current | 
            Yes | 
         
        
            | Dual Display | 
            No | 
         
        
            | Analog Bargraph on Display | 
            No | 
         
        
            | Backlight | 
            Yes | 
         
        
            | Remote Display | 
            No | 
         
        
            | Resistance | 
            Yes | 
         
        
            | Frequency | 
            No | 
         
        
            | Continuity | 
            Yes | 
         
        
            | Capacitance | 
            Yes | 
         
        
            | Temperature (K T/C) | 
            No | 
         
        
            | Temperature (IR Sensor) | 
            No | 
         
        
            | Diode Testing | 
            Yes | 
         
        
            | CAT Rating | 
            III | 
         
        
            | Overload Protector | 
            Yes | 
         
        
            | True Power (KW) | 
            No | 
         
        
            | Apparent Power (VA) | 
            No | 
         
        
            | Power Factor (PF) | 
            No | 
         
        
            | Crest Factor | 
            Yes | 
         
        
            | Energy (KWh) | 
            No | 
         
        
            | Reactive Power (KVAR) | 
            No | 
         
        
            | Source/Simulate (Process Clamp) | 
            No | 
         
        
         
        
            | Unique Features | 
            Relative Zero Mode, Third Hand Test Probe Holder | 
         
        
            | Warranty | 
            1 YEARS | 
         
        
            | Warranty Details | 
            1 Year from the Date of Purchase, This Warranty Does Not Cover Fuses, Disposable Batteries or Damage from Accident, Neglect, Misuse, Alteration, Contamination or Abnormal Conditions of Operation or Handling | 
         
        
            | Additional Info/Comments | 
            Line splitter (Energizer), 3000A AC Flexible Clamp-on Attachment, Single Input Thermocouple Temperature Attachment, Test Lead Kit | 
         
        
            | Product Weight | 
            290 GRAMS (0.639 LBS) | 
         
        
            | Product Height | 
            40 MM (1.57 IN) | 
         
        
            | Product Length | 
            227 MM (8.94 IN) | 
         
        
            | Product Width | 
            78 MM (3.07 IN) | 
         
        
            | Data Logging | 
            No | 
         
        
            | Calibration Included | 
            Factory Calibration | 
         
        
            | Battery Type | 
            AAA | 
         
        
            | Power Supply Voltage | 
            Battery Powered  | 
         
        
            | Country of Origin | 
            Taiwan  | 
         
        
            | Shipping Height | 
            3.50 IN  | 
         
        
            | Shipping Length | 
            12.00 IN  | 
         
        
            | Shipping Width | 
            7.25 IN  | 
         
        
            | Other Information | 
            
             Display: 3-3/4 digits 4000 counts LCD display 
            Update Rate: 3 per second nominal 
            Polarity: Automatic 
            Low Battery: Below approx. 2.4V 
            Operating Temperature: 0C to 40C 
            Relative Humidity: Maximum relative humidity 80% for temperature up to 31C decreasing linearly to 50% relative humidity at 40C 
            Altitude: Operating below 2000m 
            Storage Temperature: -20C to 60C, 80% R.H. (with battery removed) 
            Temperature Coefficient: nominal 0.15 x (specified accuracy)/ C @(0C -18C or 28C -40C), or otherwise specified 
            Sensing: True RMS 
            Safety: Meets EN61010-1:2001; IEC61010-2-032(2002), EN61010-2-032(2002), UL61010B-2-032(2003) Category III 600 Volts AC & DC. 
            Transient protection: 6.5kV (1.2/50µs surge) for all models 
            Pollution degree: 2 
            E.M.C.: Meets EN61326-1 
            Clamp-on jaws: DC 1000A or AC 800A rms continuous + & COM terminals (all functions) : 600VDC/VAC rms 
            Power Supply: standard 1.5V AAA Size (NEDA 24G or IEC R03) battery X 2; or 1.5V AAA Size (NEDA 24A or IEC LR03) alkaline battery X 2 
            Power Consumption: typical 11mA for ACA/DCA and 2.9mA for other functions 
            APO Timing: Idle for 30 minutes 
            APO Consumption: typical 190µA 
            Dimension: L227mm X W78mm X H40mm 
            Weight: 290 gm approx 
            Jaw opening & Conductor diameter: 50mm max 
            Electrical Specifications 
             | 
            Accuracy is ±(% reading digits + number of digits) or otherwise specified, at 23℃ ± 5℃ & less than 75% R.H. | 
         
        
            | DC Voltage | 
         
        
            |  : 400.0 mV | 
            0.3% + 3d
               
            AC Voltage 
             | 
         
        
            | 50Hz ~ 500Hz: 400.0mV 1) | 
            4.0% + 4d
               
            Resistance 
             | 
         
        
            |  : 400.0O | 
            0.8% + 6d
               
            Audible Continuity Tester 
             | 
         
        
            | Open Circuit Voltage:: 0.4VDC typical | 
             
               
            Diode Tester 
             | 
         
        
            | Open Circuit Voltage: Test Current (Typical) | 
             
               
            Capacitance 
             | 
         
        
             : 500.0nF, 5.000µF, 50.00µF, 
            500.0µF, 3000µF 1) | 
            3.5% + 6d2) 3)
               
            DC Current (Clamp-on) 
             | 
         
        
            | 400.0A: 0.0A ~ 400.0A | 
            1.5% + 4d 1) 2)
               
            AC Current (Clamp-on) 
             | 
         
        
            | 400.0A:   | 
              | 
         
    
  
                    
                    
                    
                   
                        
              
		 |