Amprobe ACD-23SW
Catalog #: 3804941
600V/400A TRMS AC Auto/Manual Swivel Clamp Meter with Temperature and Voltect
- Overview
- Specifications
- Summary
Product Highlights
- TRMS Measurement
- Temperature measurement
- 180 degree rotating head for the perfect display viewing
- Advanced VoltTect non-contact voltage detection
- Slim jaw design with one hand operation
- Measures AC Current up to 400 ACA, AC/DC, Voltage up to 600V, Resistance and Capacitance
- Audible continuity
- Auto and manual ranging respectively for quick checks and precise measurements
- Auto power off
- Data hold
- Accommodates conductors up to 1.18" (30mm) in diameter
- Safety CAT III 600 V
Each Unit Includes
- 1 - Test leads
- 1 - battery (installed)
- 1 - users manual
- 1 - carrying case
- 1 - type-K thermocouple
ELECTRICAL SPECIFICATIONS |
DC Volts |
Ranges |
400mV, 4V, 40V, 400V, 600V |
Resolution |
0.1mV |
Accuracy |
±(0.5% rdg + 2 dgts) |
Input Impedance |
400mV:>100MΩ; 4V:10MΩ;40V~600V:9.1MΩ |
Overload Protection |
600V DC or AC rms to measure millivolts, use “RANGE “ button to manually select 400mV range |
|
AC Volts (50Hz - 500Hz) |
Ranges |
4V, 40V, 400V, 600V |
Resolution |
1mV |
Accuracy |
±(1.2% rdg + 5 dgts)
±(1.2% rdg + 5 dgts) |
Input Impedance |
4V:10MΩ;40V~600V:9.1MΩ |
Overload Protection |
600V DC or AC rms |
|
AC Current (50Hz - 60Hz) |
Ranges |
40A , 400A |
Resolution |
0.01A |
Accuracy |
±(2.0% rdg + 10 dgts) 50 ~ 60Hz |
Overload Protection |
400A AC |
|
Resistance |
Ranges |
400Ω, 4kΩ, 40kΩ, 400kΩ, 4MΩ, 40MΩ |
Resolution |
0.1Ω |
Accuracy |
±(1.0% rdg + 5 dgts) on 400Ω to 400kΩ ranges |
±(1.5% rdg + 5 dgts) on 4MΩ range |
±(3.0% rdg + 5 dgts) on 40MΩ range |
Open Circuit Volts |
-0.45V DC typical, (-1.2Vdc on 400Ω range) |
Overload Protection |
600V DC or AC rms |
|
Capacitance |
Ranges |
4uF , 40uF , 400uF , 4mF |
Resolution |
1nF |
Accuracy |
±(3.0% rdg + 15 dgts) |
Minimum Input Range |
>100nF |
Overload Protection |
600V DC or AC rms when the capacitor to be tested is connected, if “dsc” symbol is indicated on LCD, it means there is voltage existing in the tested capacitor and needs to be discharged before testing. |
|
Temperature |
Range |
-30°F ~ 400°F, -35°C ~ 400°C |
Resolution |
0.1°F, 0.1°C |
Accuracy |
±(1% + 2°F) 32°F ~ 400°F ±(1% + 1°C) 0°C ~ 200°C
±(2% + 6°F) -30°F ~ 32°F ±(2% +3°C) -35°C ~ 0°C |
Sensor Type |
K-type themocouple |
Overload Protection |
60V DC or 30V AC rms |
|
Continuity |
Range |
400Ω |
Resolution |
1Ω |
Audible Indication |
Less than 25Ω |
Response Time |
500ms |
Overload Protection |
500V DC or AC rms |
|
Non-Contact Voltage Indicator |
Senses voltage 70V to 600VAC (50Hz ~ 60Hz), beeper chirps and big bright red LED comes on, works when meter dial is on any range |
|
Auxiliary Features |
Hold |
Freeze the latest reading on the display |
Range |
Excute manual range mode |
Disable Auto Power Off |
Set the DMM to off position, press (RANGE) button, and hold the (RANGE) button while turning the rotary knob to the desired range position. Release the button when LCD displays normally. Note “APO” annunciator is missing from the LCD. The Auto Power Off mode is activated with an “APO” symbol indicating on LCD. |
Clamp Meters/Clamp Meters Template |
Type |
Standard Style |
True RMS |
Yes |
Maximum Current AC |
400 A |
Minimum Current AC |
0.01 A (10 mA) |
Maximum Voltage AC |
600 V |
Minimum Voltage AC |
1 mV |
Maximum Voltage DC |
600 V |
Minimum Voltage DC |
0.1 mV |
Basic Voltage Accuracy |
ACV: ± 1.5% Rdg + 8D; DCV: ± 0.5% Rdg + 2D |
Digits Display |
3.75 |
Counts |
3999 . |
Resolution AC Volts |
1 mV (0.001 V) |
Resolution DC Volts |
0.1 mV (0.0001 V) |
Resolution AC Current |
0.01 A |
Maximum Conductor Size |
1.18 IN |
Auto Ranging/Manual |
Both |
Auto Power Off |
Yes |
Detachable Jaw |
No |
Rotating Jaw / Swivel |
Yes |
Peak Hold |
No |
Min/Max |
No |
In-Rush Current |
No |
Dual Display |
No |
Analog Bargraph on Display |
No |
Backlight |
No |
Remote Display |
No |
Resistance |
Yes |
Frequency |
No |
Continuity |
Yes |
Capacitance |
Yes |
Temperature (K T/C) |
Yes |
Temperature (IR Sensor) |
No |
Diode Testing |
No |
CAT Rating |
III |
CAT Voltage |
600 V |
Overload Protector |
Yes |
True Power (KW) |
No |
Apparant Power (VA) |
No |
Power Factor (PF) |
No |
Crest Factor |
Yes |
Energy (KWh) |
No |
Reactive Power (KVAR) |
No |
Source/Simulate (Process Clamp) |
No |
Unique Features |
TRMS AC Current to 400A
AC Voltage to 600V
DC Voltage to 600V
Resistance to 40MΩ
VolTect™ non-contact voltage detection
Capacitance to 4,000 µF
Temperature from -30°F to 400°F
Jaw fits up to 1.18" (30 mm) in diameter |
Warranty |
1 YEARS |
Warranty Details |
1 Year from the Date of Purchase, This Warranty Does Not Cover Fuses, Disposable Batteries or Damage from Accident, Neglect, Misuse, Alteration, Contamination or Abnormal Conditions of Operation or Handling |
Additional Info/Comments |
Low Battery Indication |
Safety Approval |
CE |
Product Weight |
1.26 LBS |
Product Height |
1.2 IN |
Product Length |
12 IN |
Product Width |
5.3 IN |
Data Logging |
No |
Calibration Included |
None |
Battery Type |
AAA |
Power Supply Voltage |
Battery Powered |
Country of Origin |
Taiwan |
Shipping Height |
3.50 IN |
Shipping Length |
14.40 IN |
Shipping Width |
7.55 IN |
|