				Amprobe ACDC-3400 IND
                
                
                
 			 
            
			
				Catalog #: 3434889
 750VAC/1000VDC/1000A TRMS Industrial AC/DC Clamp Meter, CAT IV, CAT III Rated
			 
			 
              
            
                
                    - Overview
 
                    - Specifications
 
                    - Summary
 
                    
                    
                    
                 
                	
                    
				        
                        Product Highlights
    - True-rms sensing increases measurement accuracy in      noisy environments
 
     
    - Measures AC/DC current up to 1000A, AC voltage to 1000V      and DC voltage to 750V, frequency, resistance, and capacitance and duty      cycle
 
     
    - Peak hold checks transients and motor start currents      for spikes
 
     
    - Relative zero displays the difference between the      actual reading and a stored reference value and may be used with any      function or range
 
     
    - Audible continuity helps quickly identify opens and      shorts
 
     
    - Auto and manual ranging for measurement speed and      flexibility
 
     
    - Data hold holds the reading on the display for further      analysis
 
     
    - Diode test quickly finds voltage drops
 
     
    - Accommodates conductors up to 2" (51mm) in      diameter
 
     
    - Safety rated to CAT IV 600V and CAT III 1000V
 
     
    - Auto power off conserves battery life
 
     
    - Backlight makes it easy to read even in dark conditions
 
 
                        Each Unit Includes
    - 1 - Deluxe carrying case
 
    - 1 - test leads
 
    - 1 - type-K thermocouple
 
    - 1 - battery (installed)
 
    - 1 - users manual
 
 
                            
                    
                          
    
        
            | Specifications (valid for 23 °C ± 5 °C, for less than 75% relative humidity). | 
         
        
            | DC Volts | 
            Ranges | 
            Accuracy | 
         
        
            |   | 
            660.0 mV, 6.600 V, 66.00 V, 660.0 V, 1000 V | 
            ± (0.5% rdg + 2 dgts) | 
         
        
            | Input impedance | 
            660 mV: >100 MΩ; 6.6 V:10 MΩ; 66 V to 1000 V: 9.1 MΩ | 
         
        
            | Overload protection | 
            1000 VDC or 750 VAC rms | 
         
        
            | AC Volts True RMS | 
            Ranges | 
            Frequency | 
            Accuracy | 
         
        
            |   | 
            660.0 mV | 
            50 to 100 Hz | 
            ± (1.5% rdg + 8 dgts) | 
         
        
            |   | 
            6.600V, 66.00V | 
            50 to 500 Hz | 
            ± (1.5% rdg + 8 dgts) | 
         
        
            |   | 
            660.0V, 750V | 
            50 to 500 Hz | 
            ± (1.5% rdg + 8 dgts) | 
         
        
            |   | 
            Frequency* | 
            50 to 1 kHz | 
            ± (0.1% rdg + 5 dgts) | 
         
        
            |   | 
            * Frequency: 10% to 100% of voltage range | 
         
        
            | Peak Hold | 
            Ranges | 
            Frequency | 
            Accuracy | 
         
        
            |   | 
            66.00V, 660.0V, 750V | 
            50 to 500 Hz | 
            ± (3.0% rdg + 300 dgts) | 
         
        
            | AC coupled TRMS | 
            5% to 100% of range | 
         
        
            | Crest factor | 
            ≤ 3 | 
         
        
            | Input impedance | 
            660 mV: >100 MΩ; 6.6 V:10 MΩ; 66 V to 750 V: 9.1 MΩ | 
         
        
            | Overload protection | 
            1000 VDC or 750 VAC rms | 
         
        
            | AC Current True RMS | 
            Ranges | 
            Frequency | 
            Accuracy | 
         
        
            |   | 
            660.0A | 
            50 to 60 Hz | 
            ± (2.0% rdg + 10 dgts) | 
         
        
            |   | 
            660.0A | 
            61 to 400 Hz | 
            ± (3.0% rdg + 10 dgts) | 
         
        
            |   | 
            1000 A | 
            50 to 60 Hz | 
            ± (2.5% rdg + 10 dgts) | 
         
        
            |   | 
            1000 A | 
            61 to 400 Hz | 
            ± (3.5% rdg + 10 dgts) | 
         
        
            |   | 
            Frequency* | 
            50 to 1kHz | 
            ± (0.1% rdg + 5 dgts) | 
         
        
            |   | 
            * Frequency: 10% to 100% of current range | 
         
        
            | Peak Hold | 
            Ranges | 
            Frequency | 
            Accuracy | 
         
        
            |   | 
            660.0A, 1000 | 
            50 to 400 Hz | 
            ± (3.0% rdg + 200 dgts) | 
         
        
            | AC coupled TRMS | 
            5% to 100% of range | 
         
        
            | Crest factor | 
            ≤ 3 | 
         
        
            | Overload protection | 
            1000A AC | 
         
        
            | DC Current | 
            Range | 
            Accuracy | 
         
        
            |   | 
            660.0A | 
            ± (2.0% rdg + 5 dgts) | 
         
        
            |   | 
            1000A | 
            ± (3.0% rdg + 5 dgts) | 
         
        
            | Overload protection | 
            1000A DC | 
         
        
            | Resistance | 
            Range | 
            Accuracy | 
         
        
            |   | 
            660.0Ω, 6.600kΩ, 66.00kΩ, 660.0kΩ | 
            ± (1.0% rdg + 5 dgts) | 
         
        
            |   | 
            6.600MΩ | 
            ± (2.0% rdg + 5 dgts) | 
         
        
            |   | 
            66.00MΩ | 
            ± (3.5% rdg + 5 dgts) | 
         
        
            | Open circuit volts | 
            -0.8 Vdc typical , (-1.2 Vdc on 660 Ω range) | 
         
        
            | Overload protection | 
            1000 VDC or 750 VAC rms | 
         
        
            | Capacitance | 
            Range | 
            Accuracy | 
         
        
            |   | 
            6.600nF, 66.00nF | 
            ±(3.0% rdg + 20 dgts) | 
         
        
            |   | 
            660.0nF, 6.600µF, 66.00µF,660.0µF | 
            ±(3.0% rdg + 10 dgts) | 
         
        
            |   | 
            6.6 mF | 
            ±(5.0% rdg + 10 dgts) | 
         
        
            | Overload protection | 
            1000 VDC or 750 VAC rms | 
         
        
            | Diode Test | 
         
        
            | Test current | 
            1.0 mA (approximate) | 
         
        
            | Accuracy | 
            ± (1.5% rdg + 5 dgts) | 
         
        
            | Open circuit volts | 
            3.2 Vdc typical | 
         
        
            | Audible indication | 
            < 0.25 V | 
         
        
            | Overload protection | 
            1000 VDC or 750 VAC rms | 
         
        
            | Continuity | 
         
        
            | Ranges | 
            660.0 Ω | 
         
        
            | Audible indication | 
            ≤ 30 Ω | 
         
        
            | Response time | 
            500 ms | 
         
        
            | Overload protection | 
            1000 VDC or 750 VAC rms | 
         
        
            | Frequency (Auto ranging) | 
            Range | 
            Accuracy | 
         
        
            |   | 
            66.00 Hz, 660.0 Hz, 6.600k Hz, 66.00 kHz, 660.0 kHz, 1.000 MHz | 
            ± (0.1% rdg + 3 dgts) | 
         
        
            | Sensitivity | 
            10 Hz to 1 MHz: > 3.5 V rms | 
         
        
            | Minimum pulse Width | 
            >1 us | 
         
        
            | % Duty Cycle | 
         
        
            | Range | 
            5.0 % to 95.0 % | 
         
        
            | Resolution: | 
            0.1 % | 
         
        
            | Minimum Pulse Width | 
            >10 us | 
         
        
            | Frequency range | 
            40 Hz to 20 kHz | 
         
        
            | Accuracy ( 5V logic ) | 
            ± (2% rdg + 10 dgts) | 
         
        
            | Overload protection | 
            1000 VDC or 750 VAC rms | 
         
    
 
  
    
        
            | Technical Data – General Information | 
         
        
            | Display | 
            3¾ digit liquid crystal display (LCD) (6600 count) with a 66-segment analog bar-graph | 
         
        
            | Polarity | 
            Automatic, positive implied, negative polarity indication | 
         
        
            | Over range | 
            (OL) or (-OL) is displayed | 
         
        
            | Zero | 
            Automatic | 
         
        
            | Low battery indication | 
            “?” is displayed when the battery voltage drops below the operating level | 
         
        
            | Auto power off | 
            Approx. 30 minutes | 
         
        
            | Backlight | 
            Backlight auto-off approx. 60 sec. | 
         
        
            | Measurement rate | 
            2.8 times per second, nominal | 
         
        
            | Analog bar-graph | 
            28 times per second | 
         
        
            | Operating environment | 
            0°C to 50°C (32°F to 122°F) at < 70% R.H. | 
         
        
            | Storage temperature | 
            -20°C to 60°C (-4°F to 140°F) at < 80% R.H. with battery removed from meter | 
         
        
            | Temperature Coefficient | 
            0.1 × (specified accuracy) per °C. (0°C to 18°C, 28°C to 50°C) | 
         
        
            | Environmental | 
            2000m (6561.7 Feet), Indoor use | 
         
        
            | Jaw opening capability | 
            57 mm (2.0 in) conductor | 
         
        
            | Power | 
            Single standard 9-volt battery, NEDA 1604, JIS 006P, IEC 6F22 | 
         
        
            | Battery life | 
            Typically 75 hours with carbon-zinc; 150 hour with alkaline | 
         
        
            | Dimensions | 
            283 x 105 x 50 mm (11.1 x 4 x 2.1 in.) | 
         
        
            | Weight | 
            559 gm (1.23 lb.) | 
         
        
            | Safety | 
            LVD Meets EN61010-1:2001 and EN61010-2-032:2002, CAT III 1000V, CAT IV 600V, class II and pollution degree 2 | 
         
        
            | EMC | 
            EN 61326-1:2006 This product complies with requirements of the following European Community Directives: 2004/108/EC (Electromagnetic Compatibility) and 2006/95/EC (Low Voltage) as amended by 93/68/EEC (CE Marking). However, electrical noise or intense electromagnetic fields in the vicinity of the equipment may disturb the measurement circuit. Measuring instruments will also respond to unwanted signals that may be present within the measurement circuit. Users should exercise care and take appropriate precautions to avoid misleading results when making measurements in the presence of electronic interference. | 
         
    
 
                     
                      
    
        
            | Clamp Meters/Clamp Meters Template | 
         
        
            | Type | 
            Standard Style | 
         
        
            | True RMS | 
            Yes | 
         
        
            | Maximum Current AC | 
            1000 A | 
         
        
            | Maximum Current DC | 
            1000 A | 
         
        
            | Maximum Voltage AC | 
            750 V | 
         
        
            | Maximum Voltage DC | 
            1000 V | 
         
        
            | Basic Voltage Accuracy | 
            ACV: ± 1.5% Rdg + 8D; DCV: ± 0.5% Rdg + 2D | 
         
        
            | Digits Display | 
            3.75 | 
         
        
            | Counts | 
            6600 . | 
         
        
            | Maximum Conductor Size | 
            2 IN | 
         
        
            | Auto Ranging/ Manual | 
            Both | 
         
        
            | Auto Power Off | 
            Yes | 
         
        
            | Detachable Jaw | 
            No | 
         
        
            | Rotating Jaw / Swivel | 
            No | 
         
        
            | Peak Hold | 
            Yes | 
         
        
            | Min/Max | 
            Yes | 
         
        
            | In-Rush Current | 
            No | 
         
        
            | Dual Display | 
            No | 
         
        
            | Analog Bargraph on Display | 
            Yes | 
         
        
            | Backlight | 
            Yes | 
         
        
            | Remote Display | 
            No | 
         
        
            | Resistance | 
            Yes | 
         
        
            | Frequency | 
            Yes | 
         
        
            | Continuity | 
            Yes | 
         
        
            | Capacitance | 
            Yes | 
         
        
            | Temperature (K T/C) | 
            No | 
         
        
            | Temperature (IR Sensor) | 
            No | 
         
        
            | Diode Testing | 
            Yes | 
         
        
            | CAT Rating  | 
            III | 
         
        
            | CAT Voltage | 
            1,000 V | 
         
        
            | Overload Protector | 
            Yes | 
         
        
            | True Power (KW) | 
            No | 
         
        
            | Apparant Power (VA) | 
            No | 
         
        
            | Power Factor (PF) | 
            No | 
         
        
            | Crest Factor | 
            Yes | 
         
        
            | Energy (KWh) | 
            No | 
         
        
            | Reactive Power (KVAR) | 
            No | 
         
        
            | Source/Simulate (Process Clamp) | 
            No | 
         
        
         
        
            | Unique Features | 
            Relative Zero, Duty Cycle, Low Battery Indication | 
         
        
            | Warranty | 
            1 YEARS | 
         
        
            | Warranty Details | 
            1 Year from the Date of Purchase, This Warranty Does Not Cover Fuses, Disposable Batteries or Damage from Accident, Neglect, Misuse, Alteration, Contamination or Abnormal Conditions of Operation or Handling | 
         
        
            | Additional Info/Comments | 
            Test Leads with Set of Alligator Clips | 
         
        
            | Product Weight | 
            1.23 LBS | 
         
        
            | Product Height | 
            2.1 IN | 
         
        
            | Product Length | 
            11.1 IN | 
         
        
            | Product Width | 
            4.3 IN | 
         
        
            | Data Logging | 
            No | 
         
        
            | Calibration Included | 
            Factory Calibration | 
         
        
            | Power Supply Voltage | 
            Battery Powered  | 
         
        
            | Country of Origin | 
            Taiwan  | 
         
        
            | Shipping Height | 
            3.25 IN  | 
         
        
            | Shipping Length | 
            12.00 IN  | 
         
        
            | Shipping Width | 
            5.75 IN  | 
         
        
            | Other Information | 
            
             Display: 3? digit liquid crystal display (LCD) (6600 count) with a 66-segment analog bar-graph 
            Polarity: Automatic, positive implied, negative polarity indication 
            Over range: (OL) or (-OL) is displayed 
            Zero: Automatic 
            Low battery indication: ?? is displayed when the battery voltage drops below the operating level 
            Auto power off: Approx. 30 minutes 
            Backlight: Backlight auto-off approx. 60 sec. 
            Measurement rate: 2.8 times per second, nominal 
            Analog bar-graph: 28 times per second 
            Operating environment: 0?C to 50?C (32?F to 122?F) at 70% R.H. 
            Storage temperature: -20?C to 60?C (-4?F to 140?F) at 80% R.H. with battery removed from meter 
            Temperature Coefficient: 0.1 ? (specified accuracy) per ?C. (0?C to 18?C, 28?C to 50?C) 
            Environmental: 2000m (6561.7 Feet), Indoor use 
            Jaw opening capability: 57 mm (2.0 in) conductor 
            Power: Single standard 9-volt battery, NEDA 1604, JIS 006P, IEC 6F22 
            Battery life: Typically 75 hours with carbon-zinc; 150 hour with alkaline 
            Dimensions: 283 x 105 x 50 mm (11.1 x 4 x 2.1 in.) 
            Weight: 559 gm (1.23 lb.) 
            Safety: LVD Meets EN61010-1:2001 and EN61010-2-032:2002, CAT III 1000V, CAT IV 600V, class II and pollution degree 2 
            EMC: EN 61326-1:2006 This product complies with requirements of the following European Community Directives: 2004/108/EC (Electromagnetic Compatibility) and 2006/95/EC (Low Voltage) as amended by 93/68/EEC (CE Marking). However, electrical noise or intense electromagnetic fields in the vicinity of the equipment may disturb the measurement circuit. Measuring instruments will also respond to unwanted signals that may be present within the measurement circuit. Users should exercise care and take appropriate precautions to avoid misleading results when making measurements in the presence of electronic interference. 
             | 
         
    
  
                    
                    
                    
                   
                        
              
		 |