Amprobe CT-500
Catalog #: 4726228
1000A Flexible Current Sensor for DM-5
- Overview
- Specifications
- Summary
Product Highlights
- Included in the DM-5 Power Quality Tester Kit
- Current Range: 1000 A, AC RMS
- Output Voltage: 500 mVac / 1000 Aac (0.5 mV / A)
- Measuring range: 0 to 1000 A (1850 Apeak)
Specifications |
CT-500 Flex Current Sensor |
Current ranges |
1000 A, AC rms |
Output voltage |
500 mVac / 1000 Aac (0.5 mV / A) |
Measuring range |
0 to 1000 A (1850 Apeak) |
Accuracy (sine wave) |
±0.8% ± 0.2 mV (45 Hz to 65 Hz)
±1.5% ± 0.2 mV (40 Hz to 1 kHz) |
Phase characteristics |
45 Hz to 65 Hz within ±2°
40 Hz to 1 kHz within ±3° |
Working voltage |
600 Vac rms |
Max allowed input |
1300 Aac continuous |
Measurable conductor size |
Max. 4.3 in (11 cm) diameter |
Head circumference |
15.75 in (40 cm) |
Head cable diameter |
0.33 in (8.5 mm) |
Cable length (head to electronics) |
Approx. 8.56 ft (2.7 m) |
Cable length (output cable) |
Approx. 0.66 ft (0.2 m) |
Output terminal |
Mini-DIN-6 connector |
Output impedance |
100 Ω or less |
Current consumption
(at power supply 3 V) |
Max. 2 mA (typical) |
Operating temperature and humidity |
14 °F to 122 °F (-10 °C to 50 °C), ≤85 %RH (no condensation)
Guaranteed accuracy at 73 °F ± 9 °F (23 °C ± 5 °C), ≤85 %RH (no condensation) |
Storage temperature and humidity |
-4 to 140 °F (-20 °C to 60 °C), ≤85 % RH (no condensation) |
Operating altitude |
0 to 6,561 ft (0 to 2,000 m) |
EMC |
EN 61326 |
Safety compliance |
UL/IEC 61010-1, IEC 61010-2-030, IEC 61010-2-032 Measurement CAT III 600 V, CAT IV 300 V, Pollution degree 2 |
Certification |
(UL tested with DM-5) |
Weight |
Approx. 0.4 lb (180 g) |
|
|
|
|