                        Product Highlights
    - Autoranging display for faster measurements
 
     
    - TTL logic test for digital circuits
 
     
    - Integrated tilt stand for easy bench use
 
     
    - Diode test for component level troubleshooting
 
     
    - Data hold freezes display to "hold"      measurement reading
 
     
    - 600V AC / 600V DC—highest voltage rating in this size      of meter
 
     
    - Special 2000 MΩ measurement range
 
 
                        Each Unit Includes
    - 1 - Pair of Test Leads (TL245A)
 
    - 1 - Fuse 2 A/ 1000 V (P/N FP200)
 
    - 1 - 9V Battery (Installed)
 
    - 1 - Magne-Grip holder with hanging strap
 
    - 1 - Users manual
 
 
                            
                    
                          
    
        
            | 15XP-B Digital Multimeter | 
         
        
            | Display | 
            3-1/2 digit liquid crystal display (LCD) with a maximum reading of 1999 | 
         
        
            | Polarity | 
            Automatic, positive implied, negative polarity indication | 
         
        
            | Overrange | 
            (OL) or (-OL) is displayed | 
         
        
            | Zero | 
            Automatic | 
         
        
            | Low Battery Indication | 
            The ?+? is displayed when the battery voltage drops below the operating level | 
         
        
            | Auto Power Off | 
            Approx. 10 minutes | 
         
        
            | Measurement Rate | 
            2 times per second, nominal | 
         
        
            | Operating Environment | 
            0 °C to 50 °C at <70 % R.H. | 
         
        
            | Storage Temperature | 
            -20 °C to 60 °C, 0 to 80 % R.H. with battery removed from meter | 
         
        
            | Accuracy | 
            Stated accuracy at 23 ?C ? 5 ?C, <75 % relative humidity | 
         
        
            | Power | 
            Single standard 9 volt battery, NEDA 1604, JIS 006P, IEC 6F22 | 
         
        
            | Battery Life | 
            200 hours typical with carbon-zinc | 
         
        
            | Dimensions | 
            (H x W x D) 155 mm x 72 mm x 32 mm | 
         
        
            | Weight | 
            Approx. 210 g including battery | 
         
        
            | Warranty | 
            One-year | 
         
    
 
  
    
        
            | Electrical Specifications | 
         
        
            | Function | 
            Range | 
            Accuracy | 
         
        
            | Voltage | 
         
        
            | DC Volts | 
         
        
            | Ranges | 
            200 mV, 2 V, 20 V, 200 V, 1000 V | 
            ± (0.5 % rdg + 1 dgt) | 
         
        
            | AC Volts (45 Hz to 500 Hz) | 
         
        
            | Ranges | 
            200 mV (45 Hz to 100 Hz) | 
            ± (1.5 % rdg + 5 dgts) | 
         
        
            |   | 
            2 V, 20 V, 200 V, 750 V | 
            ± (1.5 % rdg + 5 dgts) | 
         
        
            | Resolution | 
            100 μV | 
              | 
         
        
            | Input Impedance | 
            400 mV: >100 MW; 4 V: 10 MW; 40 V to 1000 V: 9.1 MΩ | 
              | 
         
        
            | Overload Protection | 
            1000 V DC or 750 V AC RMS | 
              | 
         
        
            | Current | 
         
        
            | DC Current | 
         
        
            | Ranges | 
            200 μA, 2000 μA, 20 mA, 200 mA | 
            ± (1.0 % rdg + 2 dgt) | 
         
        
            |   | 
            2 A | 
            ± (2.0 % rdg + 3 dgts) | 
         
        
            | AC Current (45 Hz to 500 Hz) | 
         
        
            | Ranges | 
            200 μA, 2000 μA, 20 mA, 200 mA | 
            ± (1.5 % rdg + 5 dgts) | 
         
        
            |   | 
            2 A | 
            ± (2.5 % rdg + 5 dgts) | 
         
        
            | Resolution | 
            0.1 μA | 
              | 
         
        
            | Input Protection | 
            2 A/1000 V fast blow ceramic fuse 6.3 mm x 32 mm on A input | 
              | 
         
        
            | Burden Voltage | 
            500 mV max. (2 V max. on 2 mA, 200 mA ranges) | 
              | 
         
        
            | Resistance | 
            200 Ω, 2 kΩ, 20 kΩ, 200 kΩ, 2 MΩ | 
            ± (1.0 % rdg + 4 dgts) | 
         
        
            |   | 
            2000 MΩ | 
            ± {5.0 % (rdg -10 dgts) +20 dgt} | 
         
        
            | Resolution | 
            100 mΩ | 
              | 
         
        
            | Open Circuit Voltage | 
            -0.45 V DC typical, (-1.2 V DC on 200 Ω range) | 
              | 
         
        
            | Overload Protection | 
            1000 V DC or 750 V AC RMS | 
              | 
         
        
            | Continuity | 
         
        
            | Audible Indication | 
            Less than 25 Ω | 
              | 
         
        
            | Response Time | 
            100 ms | 
              | 
         
        
            | Overload Protection | 
            1000 V DC or 750 V AC RMS | 
              | 
         
        
            | Diode Test | 
         
        
            | Test Current | 
            1.2 mA (approximate) | 
            ±(1.5 % rdg + 3 dgts) | 
         
        
            | Resolution | 
            1 mV | 
              | 
         
        
            | Open Circuit Voltage | 
            3.0 dc typical | 
              | 
         
        
            | Overload Protection | 
            1000 V DC or 750 V AC RMS | 
              | 
         
        
            | Logic Test | 
            TTL | 
              | 
         
        
            | Thresholds Logic 1 (Hi ) | 
            2.8 V ± 0.8 V | 
              | 
         
        
            | Thresholds Logic 0 (Lo) | 
            0.8 V ± 0.5 V | 
              | 
         
        
            | Test Voltage | 
            TTL 5 VDC | 
              | 
         
        
            | Frequency Range | 
            20 MHz | 
              | 
         
        
            | Pulse Width | 
            25 ns min | 
              | 
         
        
            | Duty Cycle Limits | 
            > 30 % and < 70 % | 
              | 
         
        
            | Indication | 
            40 ms beep at Logic 0 ( Lo) | 
              | 
         
        
            | Overload Protection | 
            1000 VDC or 750 VAC RMS | 
              | 
         
        
            | Non-Contact Voltage Indicator | 
         
        
            | Sense voltage 70 V to 600 V ac (50 Hz to 60 Hz) beeper chirps and big bright red LED comes on, works on all ranges | 
         
    
 
                     
                      
    
        
            | Multimeters Template | 
         
        
            | Type | 
            Digital | 
         
        
            | Style | 
            Hand-Held | 
         
        
            | Measures AC V | 
            Yes | 
         
        
            | Measures DC V | 
            Yes | 
         
        
            | Measures AC A | 
            Yes | 
         
        
            | Measures DC A | 
            Yes | 
         
        
            | True RMS | 
            No | 
         
        
            | Maximum Voltage AC | 
            750 V | 
         
        
            | Minimum Voltage AC | 
            100 uV (0.1 mV) | 
         
        
            | Resolution AC Volts | 
            100 uV (0.1 mV) | 
         
        
            | Maximum Voltage DC | 
            1000 V | 
         
        
            | Maximum Voltage AC | 
            200 mA (0.2 A) | 
         
        
            | Minimum Current AC | 
            0.1 uA (0.00010 mA) | 
         
        
            | Resolution AC Current | 
            0.1 uA (0.00010 mA) | 
         
        
            | Maximum Current DC | 
            200 mA (0.2 A) | 
         
        
            | Basic Accuracy V DC | 
            ± 0.5% rdg + 1D | 
         
        
            | # digit Display  | 
            3.5 | 
         
        
            | Counts | 
            1999 . | 
         
        
            | Backlight | 
            No | 
         
        
            |  Manual/Autoranging | 
            Auto-ranging | 
         
        
            | Dual Display | 
            No | 
         
        
            | Analog Bargraph on Display | 
            No | 
         
        
            | Decibels | 
            No | 
         
        
            | Resistance | 
            Yes | 
         
        
            | Frequency | 
            No | 
         
        
            | Countiniuty | 
            Yes | 
         
        
            | Capacitance | 
            No | 
         
        
            | Temperature | 
            No | 
         
        
            | Diode Testing | 
            Yes | 
         
        
            | CAT Rating | 
            II  | 
         
        
            | CAT Voltage | 
            1,000 V | 
         
        
            | IS | 
            No | 
         
        
            | Peak Hold | 
            No | 
         
        
            | Overload Protector | 
            Yes | 
         
        
            | Kelvin 4-Wire Measurement | 
            No | 
         
        
            | Wireless Display | 
            No | 
         
        
            | Data Hold | 
            Yes | 
         
        
            | Low-Pass Filter | 
            No | 
         
        
            | Duty Cycle % | 
            30% to 70%  | 
         
        
         
        
            | Unique Features | 
            TTL Logic Test for Digital Circuits, Integrated Tilt Stand for Easy Bench Use | 
         
        
            | Warranty | 
            1 YEARS | 
         
        
            | Warranty Details | 
            1 Year from the Date of Purchase, This Warranty Does Not Cover Fuses, Disposable Batteries or Damage from Accident, Neglect, Misuse, Alteration, Contamination or Abnormal Conditions of Operation or Handling | 
         
        
            | Additional Info/Comments | 
            Carrying Case, Test Lead Kit | 
         
        
            | Safety Approval | 
            CSA | 
         
        
            | Product Weight | 
            0.46 LBS | 
         
        
            | Product Height | 
            6.1 IN | 
         
        
            | Product Length | 
            1.26 IN | 
         
        
            | Product Width | 
            2.83 IN | 
         
        
            | Data Logging | 
            No | 
         
        
            | HTS/Schedule B Number | 
            9030.32.0000  | 
         
        
            | ECCN Number | 
            3A992  | 
         
        
            | Calibration Included | 
            Factory Calibration | 
         
        
            | Power Supply Voltage | 
            Battery Powered  | 
         
        
            | Country of Origin | 
            Taiwan  | 
         
        
            | Shipping Height | 
            2.50 IN  | 
         
        
            | Shipping Length | 
            10.05 IN  | 
         
        
            | Shipping Width | 
            7.10 IN  | 
         
        
            | Other Information | 
            
             Polarity: Automatic, positive implied, negative polarity indication 
            Overrange: (OL) or (-OL) is displayed 
            Zero: Automatic 
            Low Battery Indication: The ?+? is displayed when the battery voltage drops below the operating level 
            Auto Power Off: Approx. 10 minutes 
            Measurement Rate: 2 times per second, nominal 
            Operating Environment: 0 °C to 50 °C at 70 % R.H. 
            Storage Temperature: -20 °C to 60 °C, 0 to 80 % R.H. with battery removed from meter 
            Accuracy: Stated accuracy at 23 ?C ? 5 ?C, 75 % relative humidity 
            Power: Single standard 9 volt battery, NEDA 1604, JIS 006P, IEC 6F22 
            Battery Life: 200 hours typical with carbon-zinc 
            Dimensions: (H x W x D) 155 mm x 72 mm x 32 mm 
            Weight: Approx. 210 g including battery 
            Warranty: One-year 
            Function 
             | 
            Range | 
            Accuracy | 
         
        
            | Voltage | 
         
        
            | DC Volts | 
         
        
            | Ranges: 200 mV, 2 V, 20 V, 200 V, 1000 V | 
            ± (0.5 % rdg + 1 dgt)
               
            AC Volts (45 Hz to 500 Hz) 
             | 
         
        
            | Ranges: 200 mV (45 Hz to 100 Hz) | 
            ± (1.5 % rdg + 5 dgts)
               
            DC Current 
             | 
         
        
            | Ranges: 200 µA, 2000 µA, 20 mA, 200 mA | 
            ± (1.0 % rdg + 2 dgt)
               
            AC Current (45 Hz to 500 Hz) 
             | 
         
        
            | Ranges: 200 µA, 2000 µA, 20 mA, 200 mA | 
            ± (1.5 % rdg + 5 dgts)
               
            15XP-B Digital Multimeter 
             | 
         
        
            | Display: 3-1/2 digit liquid crystal display (LCD) with a maximum reading of 1999 | 
         
    
  
                    
                    
                    
                   
                        
              
		 |